X-ray diffraction microtomography using synchrotron radiation

被引:23
作者
Barroso, RC
Lopes, RT
de Jesus, EFO
Oliveira, LF
机构
[1] UFRJ, COPPE, Lab Instrumentacao Nucl, BR-21945970 Rio De Janeiro, Brazil
[2] Univ Estado Rio de Janeiro, Rio De Janeiro, Brazil
关键词
X-ray diffraction; microtomography; synchrotron radiation;
D O I
10.1016/S0168-9002(01)00918-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The X-ray diffraction computed tomography technique is based on the interference phenomena of the coherent scatter. For low-momentum transfer, it is most probable that the scattering interaction will be coherent. A selective discrimination of a given element in a scanned specimen can be realized by fixing the Bragg angle which produces an interference peak and then, to carry out the computed tomography in the standard mode. The image reconstructed exalts the presence of this element with respect to other ones in a sample. This work reports the feasibility of a nondestructive synchrotron radiation X-ray diffraction imaging technique. This research was performed at the X-ray Diffraction beam line of the National Synchrotron Light Laboratory (LNLS) in Brazil. The coherent scattering properties of different tissue and bone substitute materials were evaluated. Furthermore, diffraction patterns of some polycrystalline solids were studied due to industrial and environmental human exposure to these metals. The obtained diffraction patterns form the basis of a selective tomography technique. Preliminary images are presented. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:75 / 79
页数:5
相关论文
共 6 条
[1]   X-ray diffraction tomography using interference effects [J].
Barroso, RC ;
Lopes, RT ;
Goncalves, OD ;
de Assis, JT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 418 (2-3) :458-464
[2]   Image reconstruction algorithm to X-ray diffraction tomography [J].
Barroso, RC ;
Lopes, RT ;
Gonçalves, OD ;
de Assis, JT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :718-723
[3]   A versatile X-ray diffraction station at LNLS (Brazil) [J].
Cusatis, C ;
Franco, MK ;
Kakuno, E ;
Giles, C ;
Morelhao, S ;
Mello, V ;
Mazzaro, I .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :491-493
[4]   STATUS AND OUTLOOK OF COHERENT-X-RAY SCATTER IMAGING [J].
HARDING, G ;
KOSANETZKY, J .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (05) :933-944
[5]   Mercury dynamics in hair of rats exposed to methylmercury by synchrotron radiation X-ray fluorescence imaging [J].
Shimojo, N ;
HommaTakeda, S ;
Ohuchi, K ;
Shinyashiki, M ;
Sun, GF ;
Kumagai, Y .
LIFE SCIENCES, 1997, 60 (23) :2129-2137
[6]   Angular-dependent coherent scatter measured with a diagnostic x-ray image intensifier-based imaging system [J].
Westmore, MS ;
Fenster, A ;
Cunningham, IA .
MEDICAL PHYSICS, 1996, 23 (05) :723-733