An adiabatic approximation to the tissue homogeneity model for water exchange in the brain: I. Theoretical derivation

被引:325
作者
St Lawrence, KS
Lee, TY
机构
[1] St Josephs Hlth Ctr, Lawson Res Inst, London, ON, Canada
[2] St Josephs Hlth Ctr, Dept Diagnost Radiol, London, ON, Canada
[3] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5C1, Canada
关键词
cerebral blood flow; tracer kinetics; deuterium oxide; nuclear magnetic resonance; compartmental modeling;
D O I
10.1097/00004647-199812000-00011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Using the adiabatic approximation, which assumes that the tracer concentration in parenchymal tissue changes slowly relative to that in capillaries, we derived a time-domain, closed-form solution of the tissue homogeneity model. This solution, which is called the adiabatic solution, is similar in form to those of two-compartment models. Owing to its simplicity, the adiabatic solution can be used in CBF experiments in which kinetic data with only limited rime resolution or signal-to-noise ratio, or both, are obtained. Using computer simulations, we investigated the accuracy and the precision of the parameters in the adiabatic solution for values that reflect H-2-labeled water (D2O) clearance from the brain (see Part II). It was determined that of the three model parameters, (1) the vascular volume (V-i), (2) the product of extraction fraction and blood flow (EF), and (3) the clearance rate constant (k(adb)), only the last one could be determined accurately, and therefore CBF must be determined from this parameter only. From the error analysis of the adiabatic solution, it was concluded that for the D2O clearance experiments described in Part II, the coefficient of variation of CBF was approximately 7% in gray matter and 22% in white matter.
引用
收藏
页码:1365 / 1377
页数:13
相关论文
共 30 条
[21]  
LASSEN NA, 1979, TRACER KINETIC METHO, P168
[22]   Cerebral [O-15]water clearance in humans determined by PET .1. Theory and normal values [J].
Ohta, S ;
Meyer, E ;
Fujita, H ;
Reutens, DC ;
Evans, A ;
Gjedde, A .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (05) :765-780
[23]   INVIVO MEASUREMENT OF CEREBRAL OXYGEN-CONSUMPTION AND BLOOD-FLOW USING O-17 MAGNETIC-RESONANCE-IMAGING [J].
PEKAR, J ;
LIGETI, L ;
RUTTNER, Z ;
LYON, RC ;
SINNWELL, TM ;
VANGELDEREN, P ;
FIAT, D ;
MOONEN, CTW ;
MCLAUGHLIN, AC .
MAGNETIC RESONANCE IN MEDICINE, 1991, 21 (02) :313-319
[24]   MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW WITH POSITRON EMISSION TOMOGRAPHY - A COMPARISON OF [O-15]WATER TO [C-11] BUTANOL WITH DISTRIBUTED-PARAMETER AND COMPARTMENTAL-MODELS [J].
QUARLES, RP ;
MINTUN, MA ;
LARSON, KB ;
MARKHAM, J ;
MACLEOD, AM ;
RAICHLE, ME .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1993, 13 (05) :733-747
[25]  
RAICHLE ME, 1983, J NUCL MED, V24, P790
[26]   TRANSPORT OF POTASSIUM-42 FROM BLOOD TO TISSUE IN ISOLATED MAMMALIAN SKELETAL MUSCLES [J].
RENKIN, EM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1959, 197 (06) :1205-1210
[27]   KINETIC-ANALYSIS OF CEREBROVASCULAR TRANSPORT BASED ON INDICATOR DIFFUSION TECHNIQUE [J].
SAWADA, Y ;
PATLAK, CS ;
BLASBERG, RG .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 256 (03) :H794-H812
[28]   A QUANTITATIVE MODEL FOR THE MEASUREMENT OF CEREBRAL VASCULAR EXTRACTION FRACTION INVIVO FOLLOWING INTRAVENOUS-INJECTION - SIMULATION STUDIES [J].
TAKAGI, S ;
KENNY, PJ ;
GILSON, AJ .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (04) :564-573
[29]   MAGNETIC-RESONANCE-IMAGING OF PERFUSION USING SPIN INVERSION OF ARTERIAL WATER [J].
WILLIAMS, DS ;
DETRE, JA ;
LEIGH, JS ;
KORETSKY, AP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (01) :212-216
[30]  
ZIELER KL, 1965, CIRC RES, V16, P309