Room-temperature fluorescence spectroscopy of monohydroxy metabolites of polycyclic aromatic hydrocarbons on octadecyl extraction membranes

被引:10
作者
Calimag-Williams, Korina [1 ]
Goicoechea, Hector C. [1 ]
Campiglia, Andres D. [1 ]
机构
[1] Univ Cent Florida, Dept Chem, Orlando, FL 32816 USA
关键词
Monohydroxy metabolites; Polycyclic aromatic hydrocarbons; Solid-phase extraction; Room-temperature fluorescence; Urine analysis; Asymmetric least squares; SOLID-PHASE EXTRACTION; POLYCHLORINATED-BIPHENYLS; LIQUID-CHROMATOGRAPHY; WATER; URINE; PHOSPHORIMETRY; PHOSPHORESCENCE; QUANTIFICATION; FLUOROMETRY; MICROEXTRACTION;
D O I
10.1016/j.talanta.2011.07.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Urine analysis of monohydroxy metabolites is recognized as an accurate assessment of human exposure to polycyclic aromatic hydrocarbons. Despite the sophisticated arsenal of analytical tools, monitoring of monohydroxy metabolites via simple, cost effective and direct methods of analysis still remains a challenge. This article evaluates the analytical potential of solid-phase extraction room-temperature fluorescence spectroscopy for the problem at hand. Extraction membranes serve the dual purpose of sample pre-concentration and solid substrate for RTF measurements. The potential of our proposition is demonstrated with the analysis of 2-hydroxy-fluorene, 1-hydroxy-pyrene, 3-hydroxy-benzo[a]pyrene and 9-hydroxy-phenanthrene in synthetic urine samples. Signal reproducibility is improved with the aid of a sample holder specifically designed for the manual optimization of luminescence signals. Background correction of solid substrates is carried out with the aid of Asymmetric Least Squares. Recovery values for the studied metabolites varied from 99.0 +/- 1.2% (3-hydroxy-benzoialpyrene) to 99.9 +/- 0.05% (1-hydroxy-pyrene). With only 10 mL of urine sample, the limits of detection varied from 57 pg mL(-1) (2-hydroxy-fluorene) to 2 pg mL(-1) (1-hydroxy-pyrene). Additional figures of merit include a simple experimental procedure for routine screening of numerous samples and compatibility with portable instrumentation for field analysis. Because of the non-destructive nature of fluorescence measurements, membranes can be brought to the lab for subsequent elution and confirmation of compounds via high-resolution techniques. (C) 2011 Elsevier B.V. An rights reserved.
引用
收藏
页码:1805 / 1811
页数:7
相关论文
共 43 条
[1]   Solid-matrix fluorescence and phosphorescence and solid-phase microextraction of polycyclic aromatic hydrocarbons with hydrophobic paper [J].
Ackerman, AH ;
Hurtubise, RJ .
APPLIED SPECTROSCOPY, 1999, 53 (07) :770-775
[2]   Detection and quantification of PAH in drinking water by front-face fluorimetry on a solid sorbent and PLS analysis [J].
Algarra, M ;
Jiménez, V ;
de Violet, PF ;
Lamotte, M .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (04) :1103-1110
[3]  
[Anonymous], 2008, MATLAB 7 6 0
[4]   Fluorescence line-narrowing spectroscopy for probing purposes in bioanalytical and environmental chemistry [J].
Ariese, Freek ;
Bader, Arjen N. ;
Gooijer, Cees .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (02) :127-138
[5]   Solid-liquid extraction room temperature phosphorimetry and pattern recognition for screening polycyclic aromatic hydrocarbons and polychlorinated biphenyls in water samples [J].
Arruda, AF ;
Goicoechea, HC ;
Santos, M ;
Campiglia, AD ;
Olivieri, AC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (07) :1385-1391
[6]   Determination of trace levels of polychlorinated biphenyls on reversed phase octadecyl bonded silica membranes [J].
Arruda, AF ;
Campiglia, AD .
ANALYTICA CHIMICA ACTA, 1999, 386 (03) :271-280
[7]   Screening potential of solid phase extraction room temperature phosphorimetry for the analysis of polychlorinated dibenzofurans in water samples [J].
Arruda, AF ;
Campiglia, AD .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (23) :4982-4988
[8]   SOLID-SURFACE ROOM-TEMPERATURE PHOSPHORIMETRY ANALYSIS OF YOHIMBINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS [J].
AUCELIO, RQ ;
CAMPIGLIA, AD .
ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) :345-353
[9]   Solid-liquid extraction laser excited time resolved Shpol'skii spectrometry: A facile method for the direct detection of 15 priority pollutants in water samples [J].
Bystol, AJ ;
Whitcomb, JL ;
Campiglia, AD .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (12) :2566-2571
[10]   UTILIZATION OF AN INORGANIC PHOSPHOR AS A REFERENCE SIGNAL IN SOLID-SURFACE ROOM-TEMPERATURE PHOSPHORIMETRY [J].
CAMPIGLIA, AD ;
DELIMA, CG .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2165-2167