The Minimum Concentration of 1,2,3-benzotriazol to Suppress Sulfur Corrosion of Copper Windings by DBDS in Mineral Transformer Oils

被引:9
作者
Mehanna, N. A. [1 ]
Jaber, A. M. Y.
Oweimreen, G. A. [1 ]
Abulkibash, A. M. [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Chem, Dhahran 31261, Saudi Arabia
关键词
Copper; sulfur corrosion; dibenzyl disulfide; metal passivators; mineral insulating oil; power transformers; DIBENZYL DISULFIDE;
D O I
10.1109/TDEI.2015.7076785
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The incubation criterion of the 62535 standard procedure of the International Electrochemical Commission (IEC) was modified to obtain the depletion profiles for different concentrations of each of 1,2,3-benzotriazol (BTA) and dibenzyl disulfide (DBDS) when both are present in a mineral oil matrix. Measurements on BTA concentrations ranging from 0 to of 70 mg L-1 show that its depletion profile after incubation for 72 h, at room temperature, and at 150 degrees C in the presence and absence of a copper strip, is the same irrespective of the DBDS concentration. Similar measurements on DBDS at concentrations ranging from 10 to 300 mg L-1 show that identical depletion profiles are obtained as long as the BTA concentration is maintained in excess of 5 mg L-1. The results show that a minimum BTA concentration of 5 mg L-1 is needed to make the copper windings in contact with the mineral oil passive and in turn suppress their sulfur corrosion by DBDS.
引用
收藏
页码:859 / 863
页数:5
相关论文
共 18 条
[1]   Duration and Mechanism for Suppressive Effect of Triazole-based Passivators on Copper-sulfide Deposition on Insulating Paper [J].
Amimoto, T. ;
Nagao, E. ;
Tanimura, J. ;
Toyama, S. ;
Yamada, N. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (01) :257-264
[2]   Identification of Affecting Factors of Copper Sulfide Deposition on insulating Paper in Oil [J].
Amimoto, T. ;
Nagao, E. ;
Tanimura, J. ;
Toyama, S. ;
Fujita, Y. ;
Kawarai, H. ;
Yamada, N. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (01) :265-272
[3]  
[Anonymous], 2006, D127506 ASTM INT
[4]  
[Anonymous], 2004, D2440 ASTM INT
[5]  
[Anonymous], 2009, A232 CIGRE WG
[6]  
[Anonymous], 2008, 62535 IEC
[7]  
[Anonymous], 1992, 61125 IEC
[8]   Quantitative evaluation of corrosive sulfur in electrical insulating oil [J].
Ito, Takashi ;
Morishima, Yoshiyuki .
IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2008, 3 (03) :313-316
[9]   Simultaneous liquid-liquid extraction of dibenzyl disulfide, 2,6-di-tert-butyl-p-cresol, and 1,2,3-benzotriazole from power transformer oil prior to GC and HPLC determination [J].
Jaber, Abdul Muttaleb Yousef ;
Mehanna, Nemr Ahmed ;
Abulkibash, Abdalla Mahmoud .
JOURNAL OF SEPARATION SCIENCE, 2012, 35 (5-6) :750-757
[10]   Corrosive Sulfur Effects in Transformer Oils and Remedial Procedures [J].
Maina, R. ;
Tumiatti, V. ;
Pompili, M. ;
Bartnikas, R. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (06) :1655-1663