Crosslinked polyethylene (PE) was developed to reduce volumetric wear in prosthetic joints. Hip simulator studies have shown promising results but there is as yet limited clinical data. We identified three patients with bilateral total hip replacements who received a crosslinked PE liner (Marathon(TM), DePuy, Warsaw, IN, USA) on one side and a conventional PE insert (Enduron(TM), DePuy) on the contralateral side. As an assessment of in vivo PE wear, linear head penetration was measured on standardized radiographs using a validated computer-assisted technique. In all the three cases, a marked reduction of more than 70% in volumetric wear was found in association with Marathon crosslinked PE. These case reports support the efficacy of this type of crosslinked PE in a selected group that allows direct comparison of the two different materials without the influence of patient-related factors such as activity, gender, weight, or others.
引用
收藏
页码:555 / 557
页数:3
相关论文
共 9 条
[1]  
Devane PA, 1999, CLIN ORTHOP RELAT R, P59
[2]  
DIGAS G, 2003, T ORTHOP RES SOC, V28
[3]  
HARRIS WH, 1995, CLIN ORTHOP RELAT R, P46
[4]   Determination of polyethylene wear in total hip replacements with use of digital radiographs [J].
Martell, JM ;
Berdia, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (11) :1635-1641
[5]  
MARTELL JM, 2003, T ORTHOP RES SOC, V28
[6]   Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene - A hip-simulator study [J].
McKellop, H ;
Shen, FW ;
Lu, B ;
Campbell, P ;
Salovey, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (12) :1708-1725
[7]   Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls [J].
McKellop, H ;
Shen, FW ;
DiMaio, W ;
Lancaster, JG .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (369) :73-82
[8]   Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements [J].
McKellop, H ;
Shen, FW ;
Lu, B ;
Campbell, P ;
Salovey, R .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1999, 17 (02) :157-167
[9]  
Schmalzried TP, 2000, CLIN ORTHOP RELAT R, P36