Simple Dual-Spotting Procedure Enhances nLC-MALDI MS/MS Analysis of Digests with Less Specific Enzymes

被引:7
作者
Baeumlisberger, Dominic [1 ]
Rohmer, Marion [1 ]
Arrey, Tabiwang N. [1 ]
Mueller, Benjamin F. [1 ]
Beckhaus, Tobias [1 ]
Bahr, Ute [1 ]
Barka, Guenes [2 ]
Karas, Michael [1 ]
机构
[1] Goethe Univ Frankfurt, Inst Pharmaceut Chem, D-60438 Frankfurt, Germany
[2] SunChrom Wissensch Gerate GmbH, D-61381 Friedrichsdorf, Germany
关键词
MALDI-Orbitrap; elastase; nLC; spotting; DESORPTION/IONIZATION MASS-SPECTROMETRY; NANOFLOW LIQUID-CHROMATOGRAPHY; CORYNEBACTERIUM-GLUTAMICUM; PROTEIN IDENTIFICATION; PROTEOMICS; SEQUENCE; MS; SEPARATIONS; ACCURACY;
D O I
10.1021/pr2001644
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The beneficial effect of high mass accuracy in mass spectrometry is especially pronounced when using less specific enzymes as the number of theoretically possible peptides increases dramatically without any cleavage specificity defined. Together with a preceding chromatographic separation, high-resolution mass spectrometers such as the MALDI-LTQ-Orbitrap are therefore well suited for the analysis of protein digests with less specific enzymes. A combination with fast, automated, and informative MALDI-TOF/TOF analysis has already been shown to yield increased total peptide and protein identifications. Here, a simple method for nLC separation and subsequent alternating spotting on two targets for both a MALDI-LTQ-Orbitrap and a MALDI-TOF/TOF instrument is introduced. This allows for simultaneous measurements on both instruments and subsequent combination of both data sets by at in-house written software tool. The performance of this procedure was evaluated using a mixture of four standard proteins digested with elastase. Three replicate runs were examined concerning repeatability and the total information received from both instruments. A cytosolic extract of C. glutamicum was used to demonstrate the applicability to more complex samples. Database search results showed that an additional 32.3% of identified peptides were found using combined data sets in comparison to MALDI-TOF/TOF data sets.
引用
收藏
页码:2889 / 2894
页数:6
相关论文
共 24 条
[1]   An automated matrix-assisted laser desorption/ionization quadrupole Fourier transform ion cyclotron resonance mass spectrometer for "bottom-up" proteomics [J].
Brock, A ;
Horn, DM ;
Peters, EC ;
Shaw, CM ;
Ericson, C ;
Phung, QT ;
Salomon, AR .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3419-3428
[2]   Role of accurate mass measurement (±10 ppm) in protein identification strategies employing MS or MS MS and database searching [J].
Clauser, KR ;
Baker, P ;
Burlingame, AL .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2871-2882
[3]   FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISAROW, MB ;
MARSHALL, AG .
CHEMICAL PHYSICS LETTERS, 1974, 25 (02) :282-283
[4]   Interfacing matrix-assisted laser desorption/ionization mass spectrometry with column and planar separations [J].
Gusev, AI .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (6-7) :691-700
[5]   Optimization and use of peptide mass measurement accuracy in shotgun proteomics [J].
Haas, Wilhelm ;
Faherty, Brendan K. ;
Gerber, Scott A. ;
Elias, Joshua E. ;
Beausoleil, Sean A. ;
Bakalarski, Corey E. ;
Li, Xue ;
Villen, Judit ;
Gygi, Steven P. .
MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (07) :1326-1337
[6]   Comparative study of [three] LC-MALDI workflows for the analysis of complex proteomic samples [J].
Hattan, SJ ;
Marchese, J ;
Khainovski, N ;
Martin, S ;
Juhasz, P .
JOURNAL OF PROTEOME RESEARCH, 2005, 4 (06) :1931-1941
[7]   The Orbitrap: a new mass spectrometer [J].
Hu, QZ ;
Noll, RJ ;
Li, HY ;
Makarov, A ;
Hardman, M ;
Cooks, RG .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (04) :430-443
[8]   The complete Corynebacterium glutamicum ATCC 13032 genome sequence and its impact on the production of L-aspartate-derived amino acids and vitamins [J].
Kalinowski, J ;
Bathe, B ;
Bartels, D ;
Bischoff, N ;
Bott, M ;
Burkovski, A ;
Dusch, N ;
Eggeling, L ;
Eikmanns, BJ ;
Gaigalat, L ;
Goesmann, A ;
Hartmann, M ;
Huthmacher, K ;
Krämer, R ;
Linke, B ;
McHardy, AC ;
Meyer, F ;
Möckel, B ;
Pfefferle, W ;
Pühler, A ;
Rey, DA ;
Rückert, C ;
Rupp, O ;
Sahm, H ;
Wendisch, VF ;
Wiegräbe, I ;
Tauch, A .
JOURNAL OF BIOTECHNOLOGY, 2003, 104 (1-3) :5-25
[9]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[10]   Accurate mass measurements in proteomics [J].
Liu, Tao ;
Belov, Mikhail E. ;
Jaitly, Navdeep ;
Qian, Wei-Jun ;
Smith, Richard D. .
CHEMICAL REVIEWS, 2007, 107 (08) :3621-3653