Hough Transform for Clustered Microcalcifications Detection in Full-Field Digital Mammograms

被引:29
作者
Fanizzi, A. [1 ]
Basile, T. M. A. [2 ,3 ]
Losurdo, L. [1 ]
Amoroso, N. [2 ,3 ]
Bellotti, R. [2 ,3 ]
Bottigli, U. [4 ]
Dentamaro, R. [1 ]
Didonna, V. [1 ]
Fausto, A. [5 ]
Massafra, R. [1 ]
Moschetta, M. [6 ]
Tamborra, P. [1 ]
Tangaro, S. [3 ]
La Forgia, D. [1 ]
机构
[1] IRCCS Giovanni Paolo II, Natl Canc Ctr, Bari, Italy
[2] Univ Bari Aldo Moro, Dept Phys, Bari, Italy
[3] INFN Natl Inst Nucl Phys, Bari Div, Bari, Italy
[4] Univ Siena, Dept Phys Sci Earth & Environm, Siena, Italy
[5] Univ Hosp Siena, Dept Diagnost Imaging, Siena, Italy
[6] Univ Bari Aldo Moro, Interdisciplinary Dept Med, Bari, Italy
来源
APPLICATIONS OF DIGITAL IMAGE PROCESSING XL | 2017年 / 10396卷
关键词
Breast Cancer; Clustered Microcalcification Detection; Image Processing; Computer-Aided System; Hough Tranform; COMPUTER-AIDED DETECTION; SEGMENTATION; BREAST;
D O I
10.1117/12.2273814
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Many screening programs use mammography as principal diagnostic tool for detecting breast cancer at a very early stage. Despite the efficacy of the mammograms in highlighting breast diseases, the detection of some lesions is still doubtless for radiologists. In particular, the extremely minute and elongated salt-like particles of microcalcifications are sometimes no larger than 0.1 mm and represent approximately half of all cancer detected by means of mammograms. Hence the need for automatic tools able to support radiologists in their work. Here, we propose a computer assisted diagnostic tool to support radiologists in identifying microcalcifications in full (native) digital mammographic images. The proposed CAD system consists of a pre-processing step, that improves contrast and reduces noise by applying Sobel edge detection algorithm and Gaussian filter, followed by a microcalcification detection step performed by exploiting the circular Hough transform. The procedure performance was tested on 200 images coming from the Breast Cancer Digital Repository (BCDR), a publicly available database. The automatically detected clusters of microcalcifications were evaluated by skilled radiologists which asses the validity of the correctly identified regions of interest as well as the system error in case of missed clustered microcalcifications. The system performance was evaluated in terms of Sensitivity and False Positives per images (FPi) rate resulting comparable to the state-of-art approaches. The proposed model was able to accurately predict the microcalcification clusters obtaining performances (sensibility - 91.78% and FPi rate - 3.99) which favorably compare to other state-of-the-art approaches.
引用
收藏
页数:12
相关论文
共 29 条
[1]  
[Anonymous], 2016, SCI REPORTS
[2]  
[Anonymous], 2009, PEARSON ED INDIA
[3]   A two-stage method for microcalcification cluster segmentation in mammography by deformable models [J].
Arikidis, N. ;
Vassiou, K. ;
Kazantzi, A. ;
Skiadopoulos, S. ;
Karahaliou, A. ;
Costaridou, L. .
MEDICAL PHYSICS, 2015, 42 (10) :5848-5861
[4]   A completely automated CAD system for mass detection in a large mammographic database [J].
Bellotti, R. ;
De Carlo, F. ;
Tangaro, S. ;
Gargano, G. ;
Maggipinto, G. ;
Castellano, M. ;
Massafra, R. ;
Cascio, D. ;
Fauci, F. ;
Magro, R. ;
Raso, G. ;
Lauria, A. ;
Forni, G. ;
Bagnasco, S. ;
Cerello, P. ;
Zanon, E. ;
Cheran, S. C. ;
Torres, E. Lopez ;
Bottigli, U. ;
Masala, G. L. ;
Oliva, P. ;
Retico, A. ;
Fantacci, M. E. ;
Cataldo, R. ;
De Mitri, I. ;
De Nunzio, G. .
MEDICAL PHYSICS, 2006, 33 (08) :3066-3075
[5]   ANALYSIS OF CANCERS MISSED AT SCREENING MAMMOGRAPHY [J].
BIRD, RE ;
WALLACE, TW ;
YANKASKAS, BC .
RADIOLOGY, 1992, 184 (03) :613-617
[6]   Microcalcification Segmentation from Mammograms: A Morphological Approach [J].
Ciecholewski, Marcin .
JOURNAL OF DIGITAL IMAGING, 2017, 30 (02) :172-184
[7]  
DOrsi C., 2014, ACR BI-RADS Atlas: Breast Imaging Reporting and Data System-Acr]
[8]   Independent Component Analysis to Detect Clustered Microcalcification Breast Cancers [J].
Gallardo-Caballero, R. ;
Garcia-Orellana, C. J. ;
Garcia-Manso, A. ;
Gonzalez-Velasco, H. M. ;
Macias-Macias, M. .
SCIENTIFIC WORLD JOURNAL, 2012,
[9]  
Heath M, 2001, IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, P212
[10]  
Hough P.V.C., 1959, C P C, V590914, P554