Dual-Signal Readout Nanospheres for Rapid Point-of-Care Detection of Ebola Virus Glycoprotein

被引:133
|
作者
Hu, Jiao [1 ,2 ]
Jiang, Yong-Zhong [1 ,2 ]
Wu, Ling-Ling [1 ,2 ]
Wu, Zhen [1 ,2 ]
Bi, Yuhai [3 ,5 ,6 ]
Wong, Gary [5 ,6 ]
Qiu, Xiangguo [7 ]
Chen, Jianjun [4 ,6 ]
Pang, Dai-Wen [1 ,2 ]
Zhang, Zhi-Ling [1 ,2 ]
机构
[1] Wuhan Univ, Inst Adv Studies, Key Lab Analyt Chem Biol & Med, Minist Educ,Coll Chem & Mol Sci,State Key Lab Vir, Wuhan 430072, Hubei, Peoples R China
[2] Wuhan Univ, Wuhan Inst Biotechnol, Wuhan 430072, Hubei, Peoples R China
[3] Shenzhen Third Peoples Hosp, State Key Discipline Infect Dis, Shenzhen Key Lab Pathogen & Immun, Shenzhen 518112, Peoples R China
[4] Chinese Acad Sci, Wuhan Inst Virol, Key Lab Special Pathogens & Biosafety, Wuhan 430071, Hubei, Peoples R China
[5] Chinese Acad Sci, Inst Microbiol, Key Lab Pathogen Microbiol & Immunol, Beijing 100101, Peoples R China
[6] Chinese Acad Sci, Ctr Influenza Res & Early Warning, Beijing 100101, Peoples R China
[7] Univ Manitoba, Dept Med Microbiol, Publ Hlth Agcy Canada, Natl Microbiol Lab,Special Pathogens Program, Winnipeg, MB R3E 3R2, Canada
基金
加拿大健康研究院; 中国国家自然科学基金;
关键词
FLOW TEST STRIP; TIME RT-PCR; MULTIFUNCTIONAL NANOSPHERES; SENSITIVE DETECTION; QUANTUM DOTS; YELLOW-FEVER; DISEASE; ASSAY; FLUORESCENCE; GUINEA;
D O I
10.1021/acs.analchem.7b02222
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rapid detection of highly contagious pathogens is the key to increasing the probability of survival and reducing infection rates. We developed a sensitive and quantitative lateral flow assay for detection of Ebola virus (EBOV) glycoprotein with a novel multifunctional nanosphere (RNs@Au) as a reporter. Each RNs@Au contains hundreds of quantum dots and dozens of Au nanoparticles and can achieve enhanced dual signal readout (fluorescence signal for quantitative detection and colorimetric signal for visual detection). Antibody (Ab) and streptavidin (SA) were simultaneously modified onto the RNs@Au to label the target and act as signal enhancer. After the target was labeled by the Ab RNs@Au SA and captured on the test line, biotin-modified RNs@Au was used to amplify the dual signal by the reaction of SA with biotin. The assay enables naked-eye detection of 2 ng/mL glycoprotein within 20 min, and the quantitative detection limit is 0.18 ng/mL. Additionally, the assay has been successfully tested in field work for detecting EBOV in spiked urine, plasma, and tap water samples and is thus a promising candidate for early diagnosis of suspect infections in EBOV-stricken areas.
引用
收藏
页码:13105 / 13111
页数:7
相关论文
共 50 条
  • [31] Sensitive detection of organophosphorus pesticides based on the localized surface plasmon resonance and fluorescence dual-signal readout
    Wang, Kan
    Li, Qian
    Wang, Yan
    Wu, Yuanyuan
    Liu, Zewen
    Liu, Songqin
    ANALYTICA CHIMICA ACTA, 2022, 1235
  • [32] A dual-channel and dual-signal microfluidic paper chip for simultaneous rapid detection of difenoconazole and mancozeb
    Hao, Guoying
    Tian, Hongye
    Zhang, Zhong
    Qin, Xiaoxiao
    Yang, Tian
    Yuan, Li
    Yang, Xingbin
    MICROCHEMICAL JOURNAL, 2023, 190
  • [33] Oxygen-induced dual-signal point-of-care testing aptasensor for aflatoxin B1 detection using platinum nanoparticle catalysis in visual fluorometry and gravimetry
    Luo, Fang
    Zhan, Linxiu
    Deng, Ye
    Qiao, Kun
    Pan, Nan
    Weng, Zuquan
    Lin, Cuiying
    Qiu, Bin
    Lin, Zhenyu
    ANALYTICA CHIMICA ACTA, 2023, 1273
  • [34] ICP-MS and Photothermal Dual-Readout Assay for Ultrasensitive and Point-of-Care Detection of Pancreatic Cancer Exosomes
    Zhang, Yingzhi
    Wei, Yunyun
    Liu, Peng
    Zhang, Xuan
    Xu, Zhangrun
    Tan, Xiaodong
    Chen, Mingli
    Wang, Jianhua
    ANALYTICAL CHEMISTRY, 2021, 93 (33) : 11540 - 11546
  • [35] Point-of-Care Diagnostics for Rapid Malaria Infection Detection and Monitoring
    Lillehoj, Peter B.
    2019 13TH IEEE INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE & ENGINEERING (IEEE-NANOMED 2019), 2019,
  • [36] Rapid detection of bacterial meningitis using a point-of-care glucometer
    Rousseau, Geoffroy
    Asmolov, Romain
    Grammatico-Guillon, Leslie
    Auvet, Adrien
    Laribi, Said
    Garot, Denis
    Jouan, Youenn
    Dequin, Pierre-Francois
    Guillon, Antoine
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2019, 26 (01) : 41 - 46
  • [37] Rapid and sensitive point-of-care detection of Orthopoxviruses by ABICAP immunofiltration
    Stern, Daniel
    Olson, Victoria A.
    Smith, Scott K.
    Pietraszczyk, Marko
    Miller, Lilija
    Miethe, Peter
    Dorner, Brigitte G.
    Nitsche, Andreas
    VIROLOGY JOURNAL, 2016, 13
  • [38] Rapid and sensitive point-of-care detection of Orthopoxviruses by ABICAP immunofiltration
    Daniel Stern
    Victoria A. Olson
    Scott K. Smith
    Marko Pietraszczyk
    Lilija Miller
    Peter Miethe
    Brigitte G. Dorner
    Andreas Nitsche
    Virology Journal, 13
  • [39] Sensitive Dual Electrochemical-Colorimetric Point-of-Care (POC) Sensor for the Rapid Detection of Mycoplasma pneumoniae
    Gao, Qian
    Li, Yang
    Li, Qi
    Ma, Cuiping
    Shi, Chao
    ANALYTICAL LETTERS, 2023, 56 (09) : 1439 - 1453
  • [40] Resonance-Frequency Modulation for Rapid, Point-of-Care Ebola-Glycoprotein Diagnosis with a Graphene-Based Field-Effect Biotransistor
    Maity, Arnab
    Sui, Xiaoyu
    Jin, Bing
    Pu, Haihui
    Bottum, Kai J.
    Huang, Xingkang
    Chang, Jingbo
    Zhou, Guihua
    Lu, Ganhua
    Chen, Junhong
    ANALYTICAL CHEMISTRY, 2018, 90 (24) : 14230 - 14238