Dual-Signal Readout Nanospheres for Rapid Point-of-Care Detection of Ebola Virus Glycoprotein

被引:133
作者
Hu, Jiao [1 ,2 ]
Jiang, Yong-Zhong [1 ,2 ]
Wu, Ling-Ling [1 ,2 ]
Wu, Zhen [1 ,2 ]
Bi, Yuhai [3 ,5 ,6 ]
Wong, Gary [5 ,6 ]
Qiu, Xiangguo [7 ]
Chen, Jianjun [4 ,6 ]
Pang, Dai-Wen [1 ,2 ]
Zhang, Zhi-Ling [1 ,2 ]
机构
[1] Wuhan Univ, Inst Adv Studies, Key Lab Analyt Chem Biol & Med, Minist Educ,Coll Chem & Mol Sci,State Key Lab Vir, Wuhan 430072, Hubei, Peoples R China
[2] Wuhan Univ, Wuhan Inst Biotechnol, Wuhan 430072, Hubei, Peoples R China
[3] Shenzhen Third Peoples Hosp, State Key Discipline Infect Dis, Shenzhen Key Lab Pathogen & Immun, Shenzhen 518112, Peoples R China
[4] Chinese Acad Sci, Wuhan Inst Virol, Key Lab Special Pathogens & Biosafety, Wuhan 430071, Hubei, Peoples R China
[5] Chinese Acad Sci, Inst Microbiol, Key Lab Pathogen Microbiol & Immunol, Beijing 100101, Peoples R China
[6] Chinese Acad Sci, Ctr Influenza Res & Early Warning, Beijing 100101, Peoples R China
[7] Univ Manitoba, Dept Med Microbiol, Publ Hlth Agcy Canada, Natl Microbiol Lab,Special Pathogens Program, Winnipeg, MB R3E 3R2, Canada
基金
中国国家自然科学基金; 加拿大健康研究院;
关键词
FLOW TEST STRIP; TIME RT-PCR; MULTIFUNCTIONAL NANOSPHERES; SENSITIVE DETECTION; QUANTUM DOTS; YELLOW-FEVER; DISEASE; ASSAY; FLUORESCENCE; GUINEA;
D O I
10.1021/acs.analchem.7b02222
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rapid detection of highly contagious pathogens is the key to increasing the probability of survival and reducing infection rates. We developed a sensitive and quantitative lateral flow assay for detection of Ebola virus (EBOV) glycoprotein with a novel multifunctional nanosphere (RNs@Au) as a reporter. Each RNs@Au contains hundreds of quantum dots and dozens of Au nanoparticles and can achieve enhanced dual signal readout (fluorescence signal for quantitative detection and colorimetric signal for visual detection). Antibody (Ab) and streptavidin (SA) were simultaneously modified onto the RNs@Au to label the target and act as signal enhancer. After the target was labeled by the Ab RNs@Au SA and captured on the test line, biotin-modified RNs@Au was used to amplify the dual signal by the reaction of SA with biotin. The assay enables naked-eye detection of 2 ng/mL glycoprotein within 20 min, and the quantitative detection limit is 0.18 ng/mL. Additionally, the assay has been successfully tested in field work for detecting EBOV in spiked urine, plasma, and tap water samples and is thus a promising candidate for early diagnosis of suspect infections in EBOV-stricken areas.
引用
收藏
页码:13105 / 13111
页数:7
相关论文
共 50 条
  • [21] Bioorthogonal Reaction-Mediated ELISA Using Peroxide Test Strip as Signal Readout for Point-of-Care Testing
    Ran, Bei
    Xianyu, Yunlei
    Dong, Mingling
    Chen, Yiping
    Qian, Zhiyong
    Jiang, Xingyu
    ANALYTICAL CHEMISTRY, 2017, 89 (11) : 6114 - 6120
  • [22] Evaluation of a rapid antigen detection point-of-care test for respiratory syncytial virus and influenza in a pediatric hospitalized population in the Netherlands
    Bruning, Andrea H. L.
    van Dijk, Karin
    van Eijk, Hetty W. M.
    Koen, Gerrit
    van Woensel, Job B. M.
    Kruisinga, Frea H.
    Pajkrt, Dasja
    Wolthers, Katja C.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2014, 80 (04) : 292 - 293
  • [23] A microfluidic platform with digital readout and ultra-low detection limit for quantitative point-of-care diagnostics
    Li, Ying
    Xuan, Jie
    Song, Yujun
    Wang, Ping
    Qin, Lidong
    LAB ON A CHIP, 2015, 15 (16) : 3300 - 3306
  • [24] A mimotope peptide-based dual-signal readout competitive enzyme-linked immunoassay for non-toxic detection of zearalenone
    Chen, Yanjie
    Zhang, Shupei
    Hong, Zhensheng
    Lin, Yanyu
    Dai, Hong
    JOURNAL OF MATERIALS CHEMISTRY B, 2019, 7 (44) : 6972 - 6980
  • [25] Point-of-Care Testing for Sensitive Detection of the African Swine Fever Virus Genome
    Elnagar, Ahmed
    Blome, Sandra
    Beer, Martin
    Hoffmann, Bernd
    VIRUSES-BASEL, 2022, 14 (12):
  • [26] Rapid Amplification and Detection of Single-Stranded Nucleic Acids for Point-of-Care Diagnosis
    Fu, Jinglin
    Zhang, Qiaochu
    Liu, Shiming
    Puyat, Derek
    Shah, Akshay
    Ebrahimimojarad, Alireza
    Oh, Sung Won
    SMALL METHODS, 2025,
  • [27] Biosensors and Point-of-Care Devices for Bacterial Detection: Rapid Diagnostics Informing Antibiotic Therapy
    Gopal, Ashna
    Yan, Li
    Kashif, Saima
    Munshi, Tasnim
    Roy, Vellaisamy A. L.
    Voelcker, Nicolas H.
    Chen, Xianfeng
    ADVANCED HEALTHCARE MATERIALS, 2022, 11 (03)
  • [28] Portable molecular diagnostic platform for rapid point-of-care detection of mpox and other diseases
    Cavuto, Matthew L.
    Malpartida-Cardenas, Kenny
    Pennisi, Ivana
    Pond, Marcus J.
    Mirza, Sohail
    Moser, Nicolas
    Comer, Mark
    Stokes, Isobel
    Eke, Lucy
    Lant, Sian
    Szostak-Lipowicz, Katarzyna M.
    Miglietta, Luca
    Stringer, Oliver W.
    Mantikas, Katerina-Theresa
    Sumner, Rebecca P.
    Bolt, Frances
    Sriskandan, Shiranee
    Holmes, Alison
    Georgiou, Pantelis
    Ulaeto, David O.
    de Motes, Carlos Maluquer
    Rodriguez-Manzano, Jesus
    NATURE COMMUNICATIONS, 2025, 16 (01)
  • [29] Portable Point-of-Care Diagnosis Platforms and Emerging Predictive Biomarkers for Rapid Detection of Severe Dengue Viral Infection
    Vairaperumal, Tharmaraj
    Lee, Po-Tseng
    Liu, Ping-Yen
    ACS SENSORS, 2025,
  • [30] Pressure/colorimetric dual-readout immunochromatographic test strip for point-of-care testing of aflatoxin B1
    Jiang, Shan
    Zhang, Lvxia
    Li, Jizhou
    Ouyang, Hui
    Fu, Zhifeng
    TALANTA, 2021, 227