摘要
The electrochemical behavior of Ti-6Al-7Nb was investigated, and compared with that of Ti-6Al-4V alloy, which is commonly used as implant material, particularly for dentistry, orthopaedic and osteosynthesis applications. The aim of present study was to evaluate their corrosion resistance in an artificial physiological conditions using Hanks solution at 37 degrees C. This evaluation was carried out through the analysis of the potentiodynamic polarization (PD), and electrochemical impedance spectroscopy (EIS) tests. Very low current densities were obtained from the PD curves, indicating a typical passive behavior for two investigated alloys. The EIS results at open circuit potential and at different potential exhibited capacitive behavior (high corrosion resistance) with phase angles close to -90. and high impedance values at low and medium frequencies, which are indicative of the formation of a highly stable film on these alloys in the test solution. The resistance of TAN is slightly higher than that of TAV. This difference can be attributed to the alloying elements. For TAN, the formation of Nb2O5 oxide, which is chemically more stable and less soluble compared to V2O5 formed on the Ti-6Al-4V alloy, enhances resistance to dissolution of the surface film. Thus, it has been suggested that Ti-6Al-7Nb can be a better alternative to Ti6Al- 4V in simulated body fluid environment.
引用
收藏
页码:113 / 127
页数:15
相关论文
共 64 条
[1]   Fracture characteristics of fatigued Ti-6Al-4V ELI as an implant material [J].
Akahori, T ;
Niinomi, M .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1998, 243 (1-2) :237-243
[2]  
Al-Mayouf A.M., 2002, The Saudi Dental Journal, V14, P118
[3]   The effect of fluoride on the electrochemical behavior of Ti and some of its alloys for dental applications [J].
Al-Mayouf, AM ;
Al-Swayih, AA ;
Al-Mobarak, NA ;
Al-Jabab, AS .
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2004, 55 (07) :524-530
[4]   Corrosion behavior of a new titanium alloy for dental implant applications in fluoride media [J].
Al-Mayouf, AM ;
Al-Swayih, AA ;
Al-Mobarak, NA ;
Al-Jabab, AS .
MATERIALS CHEMISTRY AND PHYSICS, 2004, 86 (2-3) :320-329
[5]   Effect of potential on the corrosion behavior of a new titanium alloy for dental implant applications in fluoride media [J].
Al-Mayouf, AM ;
Al-Swayih, AA ;
Al-Mobarak, NA .
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2004, 55 (02) :88-94
[6]   The effect of hydrogen peroxide on the electrochemical behavior of Ti and some of its alloys for dental applications [J].
Al-Mobarak, N. A. ;
Al-Mayouf, A. M. ;
Al-Swayih, A. A. .
MATERIALS CHEMISTRY AND PHYSICS, 2006, 99 (2-3) :333-340
[7]   In situ impedance spectroscopy study of the electrochemical corrosion of Ti and Ti-6Al-4V in simulated body fluid at 25 °C and 37 °C [J].
Alves, V. A. ;
Reis, R. Q. ;
Santos, I. C. B. ;
Souza, D. G. ;
Goncalves, T. de F. ;
Pereira-da-Silva, M. A. ;
Rossi, A. ;
da Silva, L. A. .
CORROSION SCIENCE, 2009, 51 (10) :2473-2482
[8]  
Ameer MAM, 2002, B ELECTROCHEM, V18, P281
[9]   CORROSION OF TI-6A1-4V IN SIMULATED BODY-FLUIDS AND BOVINE PLASMA [J].
ARAGON, PJ ;
HULBERT, SF .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1972, 6 (03) :155-&
[10]   The electrochemical behaviour of Ti-13Nb-13Zr alloy in various solutions [J].
Assis, S. L. ;
Wolynec, S. ;
Costa, I. .
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2008, 59 (09) :739-743