An aqueous-based surface modification of poly(dimethylsiloxane) with poly(ethylene glycol) to prevent biofouling

被引:134
作者
Lee, S [1 ]
Vörös, J [1 ]
机构
[1] ETH Honggerberg, Swiss Fed Inst Technol, Dept Mat, Surface Sci & Technol Lab, CH-8093 Zurich, Switzerland
关键词
D O I
10.1021/la051932p
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We report a simple modification of poly(dimethylsiloxane) (PDMS) surfaces with poly(ethylene glycol) (PEG) through the adsorption of a graft copolymer, poly(L-lysine)-graft-poly(ethylene glycol) (PLL-g-PEG) from aqueous solution. In this approach, the PDMS surface was treated with oxygen plasma, followed by immersion into aqueous solution containing PLL-g-PEG copolymers. Due to the hydroxyl./carboxylic groups generated on the PDMS surface after oxygen plasma, the polycationic PLL backbone is attracted to the negatively charged surface and PEG side chains exhibit an extended structure. The PEG/aqueous interface generated in this way revealed a near-perfect resistance to nonspecific protein adsorption as monitored by means of optical waveguide lightmode spectroscopy (OWLS) and fluorescence microscopy.
引用
收藏
页码:11957 / 11962
页数:6
相关论文
共 35 条
[1]  
CHOI HG, P 7 INT C MIN CHEM B
[2]   Microcontact printing using poly(dimethylsiloxane) stamps hydrophilized by poly(ethylene oxide) silanes [J].
Delamarche, E ;
Donzel, C ;
Kamounah, FS ;
Wolf, H ;
Geissler, M ;
Stutz, R ;
Schmidt-Winkel, P ;
Michel, B ;
Mathieu, HJ ;
Schaumburg, K .
LANGMUIR, 2003, 19 (21) :8749-8758
[3]  
Delamarche E, 2001, ADV MATER, V13, P1164
[4]   Compressing PEG brushes [J].
Drobek, T ;
Spencer, ND ;
Heuberger, M .
MACROMOLECULES, 2005, 38 (12) :5254-5259
[5]   Swelling of crosslinked polydimethylsiloxane networks by pure solvents: Influence of temperature [J].
Favre, E .
EUROPEAN POLYMER JOURNAL, 1996, 32 (10) :1183-1188
[6]   Solution assembled and microcontact printed monolayers of dodecanethiol on gold: A multivariate exploration of chemistry and contamination [J].
Graham, DJ ;
Price, DD ;
Ratner, BD .
LANGMUIR, 2002, 18 (05) :1518-1527
[7]   About the role of water in surface-grafted poly(ethylene glycol) layers [J].
Heuberger, M ;
Drobek, T ;
Vörös, J .
LANGMUIR, 2004, 20 (22) :9445-9448
[8]   A comparative study of protein adsorption on titanium oxide surfaces using in situ ellipsometry, optical waveguide lightmode spectroscopy, and quartz crystal microbalance/dissipation [J].
Höök, F ;
Vörös, J ;
Rodahl, M ;
Kurrat, R ;
Böni, P ;
Ramsden, JJ ;
Textor, M ;
Spencer, ND ;
Tengvall, P ;
Gold, J ;
Kasemo, B .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2002, 24 (02) :155-170
[9]   Biotin-derivatized poly(L-lysine)-g-poly(ethylene glycol):: A novel polymeric interface for bioaffinity sensing [J].
Huang, NP ;
Vörös, J ;
De Paul, SM ;
Textor, M ;
Spencer, ND .
LANGMUIR, 2002, 18 (01) :220-230
[10]   Surface modification using silanated poly(ethylene glycol)s [J].
Jo, S ;
Park, K .
BIOMATERIALS, 2000, 21 (06) :605-616