In vivo validation of a realistic kinematic model for the trapezio-metacarpal joint using an optoelectronic system

被引:29
作者
Cerveri, P. [1 ]
De Momi, E. [1 ]
Marchente, M. [1 ]
Lopomo, N. [1 ,2 ]
Baud-Bovy, G. [3 ]
Barros, R. M. L. [4 ]
Ferrigno, G. [1 ]
机构
[1] Politecn Milan, Dept Bioengn, I-20133 Milan, Italy
[2] Ist Ortoped Rizzoli, Biomech Lab, I-40136 Bologna, Italy
[3] San Raffaele Vita Salute Univ, San Raffaele Fdn, IIT Network Res Unit Mol Neurosci, Fac Psychol, I-20132 Milan, Italy
[4] Univ Estadual Campinas, Fac Educ Fis, Lab Instrumentacao Biomecan, Campinas, Brazil
关键词
trapezio-metacarpal joint; thumb motion; kinematic model; surface markers;
D O I
10.1007/s10439-008-9499-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article analyzes a realistic kinematic model of the trapezio-metacarpal (TM) joint in the human thumb that involves two non-orthogonal and non-intersecting rotation axes. The estimation of the model parameters, i.e. the position and orientation of the two axes with respect to an anatomical coordinate system, was carried out by processing the motion of nine retroreflective markers, externally attached to the hand surface, surveyed by a video motion capture system. In order to compute the model parameters, prototypical circumduction movements were processed within an evolutionary optimization approach. Quality and reproducibility in assessing the parameters were demonstrated across multiple testing sessions on 10 healthy subjects (both left and right thumbs), involving the complete removal of all markers and then retesting. Maximum errors of less than 5 mm in the axis position and less than 6 degrees in the orientation were found, respectively. The inter-subject mean distance between the two axes was 4.16 and 4.71 mm for right and left TM joints, respectively. The inter-subject mean relative orientation between the two axes was about 106 and 113 degrees for right and left TM joints, respectively. Generalization properties of the model were evaluated quantitatively on opposition movements in terms of distance between measured and predicted marker positions (maximum error less than 5 mm). The performance of the proposed model compared favorably with the one (maximum error in the range of 7-8 mm) obtained by applying a universal joint model (orthogonal and intersecting axes). The ability of in vivo estimating the parameters of the proposed kinematic model represents a significant improvement for the biomechanical analysis of the hand motion.
引用
收藏
页码:1268 / 1280
页数:13
相关论文
共 31 条
[1]   NORMATIVE MODEL OF HUMAN HAND FOR BIOMECHANICAL ANALYSIS [J].
AN, KN ;
CHAO, EY ;
COONEY, WP ;
LINSCHEID, RL .
JOURNAL OF BIOMECHANICS, 1979, 12 (10) :775-788
[2]   Material properties of the trapezial and trapeziometacarpal ligaments [J].
Bettinger, PC ;
Smutz, P ;
Linscheid, RL ;
Cooney, WP ;
An, KN .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (06) :1085-1095
[3]   A three-dimensional kinematic model of the human long finger and the muscles that actuate it [J].
Biggs, J ;
Horch, K .
MEDICAL ENGINEERING & PHYSICS, 1999, 21 (09) :625-639
[4]   Quantitative analysis of finger motion coordination in hand manipulative and gestic acts [J].
Braido, P ;
Zhang, XD .
HUMAN MOVEMENT SCIENCE, 2004, 22 (06) :661-678
[5]   A KINEMATIC MODEL OF THE HUMAN HAND TO EVALUATE ITS PREHENSILE CAPABILITIES [J].
BUCHHOLZ, B ;
ARMSTRONG, TJ .
JOURNAL OF BIOMECHANICS, 1992, 25 (02) :149-162
[6]   Finger kinematic modeling and real-time hand motion estimation [J].
Cerveri, P. ;
De Momi, E. ;
Lopomo, N. ;
Baud-Bovy, G. ;
Barros, R. M. L. ;
Ferrigno, G. .
ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (11) :1989-2002
[7]   Derivation of Centers and axes of rotation for wrist and fingers in a hand kinematic model: Methods and reliability results [J].
Cerveri, P ;
Lopomo, N ;
Pedotti, A ;
Ferrigno, G .
ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (03) :402-412
[8]   Combined evolution strategies for dynamic calibration of video-based measurement systems [J].
Cerveri, P ;
Pedotti, A ;
Borghese, NA .
IEEE TRANSACTIONS ON EVOLUTIONARY COMPUTATION, 2001, 5 (03) :271-282
[9]  
Cheze L, 2001, Chir Main, V20, P23, DOI 10.1016/S1297-3203(01)00011-7
[10]   The use of the motion analysis system for evaluation of loss of movement in the finger [J].
Chiu, HY ;
Lin, SC ;
Su, FC ;
Wang, ST ;
Hsu, HY .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (02) :195-199