Wear performance of all-polymer PEEK articulations for a cervical total level arthroplasty system

被引:4
作者
Langohr, G. D. G. [1 ]
Gawel, H. A. [2 ]
Medley, J. B. [1 ]
机构
[1] Univ Waterloo, Dept Mech & Mechatron Engn, Waterloo, ON N2L 3G1, Canada
[2] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Philadelphia, PA 19104 USA
基金
加拿大自然科学与工程研究理事会;
关键词
PEEK; pin-on-disc machine; cervical disc arthroplasty; PEEK-OPTIMA; PAN CFR PEEK-OPTIMA; facet joint replacement; MOTION; DISKECTOMY; FUSION;
D O I
10.1177/2041305X10395062
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Pin-on-plate wear testing of polyetheretherketone (PEEK) was performed in a PEEK-on-PEEK configuration to explore the tribology of this rather uncommon contact configuration. To illustrate its possible application, a total level cervical arthroplasty system was described. Also, it was noted that previous pin-on-plate and simulator studies of this type of material pairing had been conducted. The present study continued the protocol of testing under an adverse loading regime that was originally introduced by Austin et al. to investigate the sensitivity of all-polymer PEEK articulations to previous wear damage. A gravimetric wear assessment protocol was used that avoided vacuum drying. The lower wear of polyacrylonitrile carbon fibre-reinforced PEEK compared with unfilled PEEK, as found by many other studies, was confirmed. PEEK was shown to have remarkably low wear despite previous adverse load testing. The coefficient of friction was found to be quite high (up to 0.5) and this might have clinical implications. Finally, it was noted that the comparison of wear factors and wear amounts from the present study (and other previous studies) with those of the very similar study by Scholes and Unsworth suggested that their laboratory model might be overstating the wear of all-polymer PEEK articulations for potential applications in orthopaedic tribology.
引用
收藏
页码:499 / 513
页数:15
相关论文
共 27 条
[1]  
AUSTIN HA, 2010, P 56 ANN M ORTH RES
[2]  
AUSTIN HA, 2008, THESIS U WATERLOO WA
[3]  
Bao Qi-Bin, 2007, SAS J, V1, P36, DOI 10.1016/SASJ-2006-0007-RR
[4]  
Bragdon C R, 1996, Proc Inst Mech Eng H, V210, P157, DOI 10.1243/PIME_PROC_1996_210_408_02
[5]   An In Vitro Biotribological Assessment of NUBAC, a Polyetheretherketone-on-Polyetheretherketone Articulating Nucleus Replacement Device Methodology and Results From a Series of Wear Tests Using Different Motion Profiles, Test Frequencies, and Environmental Conditions [J].
Brown, Tim ;
Bao, Qi-Bin ;
Kilpela, Tom ;
Songer, Matthew .
SPINE, 2010, 35 (16) :E774-E781
[6]   Range of motion change after cervical arthroplasty with ProDisc-C and Prestige artificial discs compared with anterior cervical discectomy and fusion [J].
Chang, Ung-Kyu ;
Kim, Daniel H. ;
Lee, Max C. ;
Willenberg, Rafer ;
Kim, Se-Hoon ;
Lim, Jesse .
JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (01) :40-46
[7]   Changes in adjacent-level disc pressure and facet joint force after cervical arthroplasty compared with cervical discectomy and fusion [J].
Chang, Ung-Kyu ;
Kim, Daniel H. ;
Lee, Max C. ;
Willenberg, Rafer ;
Kim, Se-Hoon ;
Lim, Jesse .
JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (01) :33-39
[8]  
Clark CR., 2005, CERVICAL SPINE
[9]  
CORIC D, 2010, P SAS10 ANN C NEW OR
[10]   The relationship between facet joint osteoarthritis and disc degeneration of the lumbar spine: an MRI study [J].
Fujiwara, A ;
Tamai, K ;
Yamato, M ;
An, HS ;
Yoshida, H ;
Saotome, K ;
Kurihashi, A .
EUROPEAN SPINE JOURNAL, 1999, 8 (05) :396-401