Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction for SPECT

被引:16
作者
Tang, QL [1 ]
Zeng, GSL
Gullberg, GT
机构
[1] Univ Utah, Dept Phys, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Radiol, Salt Lake City, UT 84108 USA
[3] EO Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
关键词
D O I
10.1088/0031-9155/50/13/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we developed an analytical fan-beam reconstruction algorithm that compensates for uniform attenuation in SPECT. The new fan-beam algorithm is in the form of backprojection first, then filtering, and is mathematically exact. The algorithm is based on three components. The first one is the established generalized central-slice theorem, which relates the I D Fourier transform of a set of arbitrary data and the 2D Fourier transform of the backprojected image. The second one is the fact that the backprojection of the fan-beam measurements is identical to the backprojection of the parallel measurements of the same object with the same attenuator. The third one is the stable analytical reconstruction algorithm for uniformly attenuated Radon data, developed by Metz and Pan. The fan-beam algorithm is then extended into a cone-beam reconstruction algorithm, where the orbit of the focal point of the cone-beam imaging geometry is a circle. This orbit geometry does not satisfy Tuy's condition and the obtained cone-beam algorithm is an approximation. In the cone-beam algorithm, the cone-beam data are first backprojected into the 3D image volume; then a slice-by-slice filtering is performed. This slice-by-slice filtering procedure is identical to that of the fan-beam algorithm. Both the fan-beam and cone-beam algorithms are efficient, and computer simulations are presented. The new cone-beam algorithm is compared with Bronnikov's cone-beam algorithm, and it is shown to have better performance with noisy projections.
引用
收藏
页码:3153 / 3170
页数:18
相关论文
共 24 条
[1]   COMPENSATION OF TISSUE ABSORPTION IN EMISSION TOMOGRAPHY [J].
BELLINI, S ;
PIACENTINI, M ;
CAFFORIO, C ;
ROCCA, F .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1979, 27 (03) :213-218
[2]   A filtering approach to image reconstruction in 3D SPECT [J].
Bronnikov, AV .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09) :2639-2651
[3]   ATTENUATED RADON AND ABEL TRANSFORMS [J].
CLOUGH, AV ;
BARRETT, HH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1983, 73 (11) :1590-1595
[4]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[5]  
GULBERG GT, 1983, EMISSION COMPUTED TE, P33
[6]  
GULBERG GT, 1995, IEEE T NUCL SCI, V42, P1257
[7]   RECONSTRUCTION OF FAN-BEAM DATA BY FILTERING THE BACK-PROJECTION [J].
GULLBERG, GT .
COMPUTER GRAPHICS AND IMAGE PROCESSING, 1979, 10 (01) :30-47
[8]   CONE BEAM TOMOGRAPHY OF THE HEART USING SINGLE-PHOTON EMISSION-COMPUTED TOMOGRAPHY [J].
GULLBERG, GT ;
CHRISTIAN, PE ;
ZENG, GSL ;
DATZ, FL ;
MORGAN, HT .
INVESTIGATIVE RADIOLOGY, 1991, 26 (07) :681-688
[9]   THE USE OF FILTERING METHODS TO COMPENSATE FOR CONSTANT ATTENUATION IN SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY [J].
GULLBERG, GT ;
BUDINGER, TF .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (02) :142-157
[10]   THE CIRCULAR HARMONIC TRANSFORM FOR SPECT RECONSTRUCTION AND BOUNDARY-CONDITIONS ON THE FOURIER-TRANSFORM OF THE SINOGRAM [J].
HAWKINS, WG ;
LEICHNER, PK ;
YANG, NC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (02) :135-148