Chemiluminescence nitrogen detection in ion chromatography for the determination of nitrogen-containing anions

被引:15
作者
Lucy, CA [1 ]
Harrison, CR [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
关键词
chemiluminescence nitrogen detection; detection; LC; inorganic anions;
D O I
10.1016/S0021-9673(01)00711-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Chemiluminescence nitrogen detection (CLND) provides equimolar response for nitrogen-containing ions such as nitrate, nitrite, cyanide, ammonium and tetradecyltrimethylammonium. Only azide yields a lower response. Nitrite, azide and nitrate are separated on a Dionex AS11 column using 5 mM NaOH as eluent with a 3 muM (1 ng N) limit of detection. Matrices, such as 1:10 diluted seawater, do not degrade these detection limits. CLND also provides equally sensitive (Limit of detection 3 muM, 78 ppb) detection of weak acids such, as cyanide, which yield poor sensitivity with suppressed conductivity detection. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 22 条
  • [1] BOEHM KA, 1995, J AOAC INT, V78, P301
  • [2] BORNY JF, 1998, ANTEK 8060 MANUAL
  • [3] Enhanced conductometric detection of cyanide in suppressed ion chromatography
    Caliamanis, A
    McCormick, MJ
    Carpenter, PD
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 884 (1-2) : 75 - 80
  • [4] CHANG R, 1991, CHEMISTRY, P377
  • [5] A study of the thermal decomposition of azidoacetone by photoelectron and matrix isolation spectroscopy
    Dyke, JM
    Groves, AP
    Morris, A
    Ogden, JS
    Catarino, MI
    Dias, AA
    Oliveira, AMS
    Costa, ML
    Barros, MT
    Cabral, MH
    Moutinho, AMC
    [J]. JOURNAL OF PHYSICAL CHEMISTRY A, 1999, 103 (41) : 8239 - 8245
  • [6] Chemiluminescent nitrogen detection for HPLC: An important new tool in organic analytical chemistry
    Fitch, WL
    Szardenings, AK
    Fujinari, EM
    [J]. TETRAHEDRON LETTERS, 1997, 38 (10) : 1689 - 1692
  • [7] Determination of molecular-mass distribution of food-grade protein hydrolyzates by size-exclusion chromatography and chemiluminescent nitrogen detection
    Fujinari, EM
    Manes, JD
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1997, 763 (1-2) : 323 - 329
  • [8] NITROGEN-SPECIFIC LIQUID-CHROMATOGRAPHY DETECTOR BASED ON CHEMILUMINESCENCE - APPLICATION TO THE ANALYSIS OF AMMONIUM NITROGEN IN WASTE-WATER
    FUJINARI, EM
    COURTHAUDON, LO
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 592 (1-2): : 209 - 214
  • [9] POSTCOLUMN LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF CYANIDE WITH FLUOROMETRIC DETECTION
    GAMOH, K
    IMAMICHI, S
    [J]. ANALYTICA CHIMICA ACTA, 1991, 251 (1-2) : 255 - 259
  • [10] MECHANISM AND MODELING OF HYDROGEN-CYANIDE OXIDATION IN A FLOW REACTOR
    GLARBORG, P
    MILLER, JA
    [J]. COMBUSTION AND FLAME, 1994, 99 (3-4) : 475 - 483