A Quasi-DC Potential Drop Measurement System for Material Testing

被引:11
作者
Corcoran, Joseph [1 ]
Davies, Catrin M. [1 ]
Cawley, Peter [1 ]
Nagy, Peter B. [1 ,2 ]
机构
[1] Imperial Coll London, Dept Mech Engn, London SW7 2AZ, England
[2] Univ Cincinnati, Dept Aerosp Engn & Engn Mech, Cincinnati, OH 45221 USA
基金
英国工程与自然科学研究理事会;
关键词
Cracks; creep; electrical resistance measurement; fatigue; voltage measurement; CRACK INITIATION; GROWTH; PROPAGATION; LOAD;
D O I
10.1109/TIM.2019.2908509
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Potential drop (PD) measurements are well established for use in materials testing and are commonly used for crack growth and strain monitoring. Traditionally, the experimenter has a choice between employing direct current (dc) or alternating current (ac), both of which have strengths and limitations. The dc measurements are afflicted by competing spurious dc signals and, therefore, require large measurement currents (tens or hundreds of amperes) to improve the signal-to-noise ratio, which in turn leads to the significant resistive Joule heating. The ac measurements have superior noise performance due to the utilization of phase-sensitive detection and a lower spectral noise density but are subject to the skin effect and are, therefore, not well suited to high-accuracy scientific studies of ferromagnetic materials. In this paper, a quasi-dc monitoring system is presented which uses very low-frequency (0.3-30-Hz) current which combines the positive attributes of both dc and ac while mitigating the negatives. Bespoke equipment has been developed that is capable of low-noise measurements in the demanding quasi-dc regime. A creep crack growth test and fatigue test are used to compare noise performance and measurement power against alternative DCPD equipment. The combination of the quasi-dc methodology and the specially designed electronics yields exceptionally low-noise measurements using typically 100-400 mA; at 400 mA, the quasi-dc system achieves a 13-fold improvement in signal-to-noise ratio compared to a 25-A dc system. The reduction in measurement current from 25 A to 400 mA represents a similar to 3900-fold reduction in measurement power, effectively eliminating resistive heating and enabling much simpler experimental arrangements.
引用
收藏
页码:1313 / 1326
页数:14
相关论文
共 46 条
[1]  
[Anonymous], 2012, COMS MULT
[2]  
[Anonymous], NFPA70
[3]  
[Anonymous], 2016, ASTME64715E1
[4]  
[Anonymous], 2010, INTRO ENG EXPT
[5]  
[Anonymous], INT J FRACT MECH
[6]   Theory of four-point alternating current potential drop measurements on a metal half-space [J].
Bowler, N .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (03) :584-589
[7]   Four-point potential drop measurements for materials characterization [J].
Bowler, Nicola .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (01)
[8]  
Catlin W. R., 1985, AUTOMATED FATIGUE TE, P310
[9]   Magnetic Stress Monitoring Using a Directional Potential Drop Technique [J].
Corcoran, J. ;
Nagy, P. B. .
JOURNAL OF NONDESTRUCTIVE EVALUATION, 2018, 37 (03)
[10]   Monitoring creep damage at a weld using a potential drop technique [J].
Corcoran, J. ;
Nagy, P. B. ;
Cawley, P. .
INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2017, 153 :15-25