A Low-Power Portable ECG Touch Sensor with Two Dry Metal Contact Electrodes

被引:14
|
作者
Yan, Long [1 ,2 ]
Yoo, Hoi-Jun [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dep EE, Taejon 305701, South Korea
[2] Korea Adv Inst Sci & Technol, Semicond Syst Lab, Taejon 305701, South Korea
关键词
ECG; touch sensor; dry electrode; portable; equivalent sensing circuit model; instrumentation amplifier; LINE INTERFERENCE; 2-ELECTRODE;
D O I
10.5573/JSTS.2010.10.4.300
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes the development of a low-power electrocardiogram (ECG) touch sensor intended for the use with two dry metal electrodes. An equivalent ECG extraction circuit model encountered in a ground-free two-electrode configuration is investigated for an optimal sensor read-out circuit design criteria. From the equivalent circuit model, (1) maximum sensor resolution is derived based on the electrode's background thermal noise, which originates from high electrode-skin contact impedance, together with the input referred noise of instrumentation amplifier (IA), (2) 60 Hz electrostatic coupling from mains and motion artifact are also considered to determine minimum requirement of common mode rejection ratio (CMRR) and input impedance of IA. A dedicated ECG read-out front end incorporating chopping scheme is introduced to provide an input referred circuit noise of 1.3 mu V-rms over 0.5 Hz similar to 200 Hz, CMRR of IA > 100 dB, sensor resolution of 7 bits, and dissipating only 36 mu W. Together with 8 bits synchronous successive approximation register (SAR) ADC, the sensor IC chip is implemented in 0.18 mu m CMOS technology and integrated on a 5 cm x 8 cm PCB with two copper patterned electrodes. With the help of proposed touch sensor, ECG signal containing QRS complex and P, T waves are successfully extracted by simply touching the electrodes with two thumbs.
引用
收藏
页码:300 / 308
页数:9
相关论文
共 48 条
  • [1] A low-power portable ECG sensor interface with dry electrodes
    Pu Xiaofei
    Wan Lei
    Zhang Hui
    Qin Yajie
    Hong Zhiliang
    JOURNAL OF SEMICONDUCTORS, 2013, 34 (05)
  • [2] A low-power portable ECG sensor interface with dry electrodes
    浦小飞
    万磊
    张辉
    秦亚杰
    洪志良
    Journal of Semiconductors, 2013, (05) : 104 - 109
  • [3] A Low-Power Bio-Potential Acquisition System with Flexible PDMS Dry Electrodes for Portable Ubiquitous Healthcare Applications
    Chen, Chih-Yuan
    Chang, Chia-Lin
    Chang, Chih-Wei
    Lai, Shin-Chi
    Chien, Tsung-Fu
    Huang, Hong-Yi
    Chiou, Jin-Chern
    Luo, Ching-Hsing
    SENSORS, 2013, 13 (03) : 3077 - 3091
  • [4] ECG Sensor Interface in a Low Power SoC for Wireless Portable ECG Monitoring
    Giroud, F.
    Persechini, P.
    Ruedi, P. -F.
    Viemon, F.
    Masson, F.
    2014 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2014, : 149 - 152
  • [5] Dry contact electrodes performance in canine ECG
    Virtanen, Juhani
    Leivo, Joni
    Vehkaoja, Antti
    Somppi, Sanni
    Tornqvist, Heini
    Fiedler, Patrique
    Vaataja, Heli
    Surakka, Veikko
    FIFTH INTERNATIONAL CONFERENCE ON ANIMAL-COMPUTER INTERACTION (ACI 2018), 2018,
  • [6] A Configurable and Low-Power Mixed Signal SoC for Portable ECG Monitoring Applications
    Kim, Hyejung
    Kim, Sunyoung
    Van Helleputte, Nick
    Artes, Antonio
    Konijnenburg, Mario
    Huisken, Jos
    Van Hoof, Chris
    Yazicioglu, Refet Firat
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2014, 8 (02) : 257 - 267
  • [7] Power Autonomy Estimation of Low-Power Sensor for Long-Term ECG Monitoring
    Bregar, Klemen
    Kristofelc, Tomaz
    Depolli, Matjaz
    Avbelj, Viktor
    Rashkovska, Aleksandra
    SENSORS, 2022, 22 (14)
  • [8] Low-Power ECG Processing ASIC
    Matsumoto, Yuki
    Tanaka, Tomoya
    Sonoda, Koji
    Kanda, Kensuke
    Fujita, Takayuki
    Maenaka, Kazusuke
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2016, 99 (04) : 13 - 20
  • [9] A portable, low-power, wireless two-lead EKG system
    Fulford-Jones, TRF
    Wei, GY
    Welsh, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2141 - 2144
  • [10] LOW-NOISE AND COST-EFFECTIVE ACTIVE ELECTRODES FOR DRY CONTACT ECG APPLICATIONS
    Voropai, A.
    Sarana, V
    SCIENCE AND INNOVATION, 2022, 18 (01): : 112 - 123