Nanoband electrode for high-performance in-channel amperometric detection in dual-channel microchip capillary electrophoresis

被引:19
|
作者
Chen, Chuanpin [1 ]
Teng, Wei [1 ]
Hahn, Jong Hoon [1 ]
机构
[1] Pohang Univ Sci & Technol, BK Sch Mol Sci, Dept Chem, Pohang 790784, South Korea
关键词
Capillary electrophoresis; Dual-channel; Electrochemical detection; In-channel detection; Microchip; BAND ELECTRODES; FARADAIC ELECTROCHEMISTRY; MICROELECTRODE ARRAYS; NANOELECTRODE ARRAYS; FABRICATION; ULTRAMICROELECTRODES; POLY(DIMETHYLSILOXANE); MICROCYLINDER; VOLTAMMETRY; DIMENSIONS;
D O I
10.1002/elps.201000661
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A nanoband electrode detector integrated with a dual-channel polydimethylsiloxane microchip is proposed for in-channel amperometric detection in microchip capillary electrophoresis. Gold nanoband electrodes, which were fabricated on SU-8 substrates with a 100-nm-width gold layer, were introduced into the dual-channel microchip to be an electrochemical detector. Due to the nano-sized width of the detector, the noise of the amperometric detection was significantly reduced, and a high separation resolution was achieved for monitoring the analytes. The detection sensitivity of the system was improved by high signal-to-noise ratio, and a low detection limit on microchip was obtained for p-aminophenol (2.09 nM). Because of the high resolution in measuring half-peak width, the plate number that is used to evaluate the separation efficiency was 1.5-fold higher than that using 50-mu m-width electrochemical detector. The effect of sample injection time and data acquisition time on separation efficiency was investigated, and an attractive separation efficiency was achieved with a plate number up to 17 500.
引用
收藏
页码:838 / 843
页数:6
相关论文
共 50 条
  • [21] Thermostatted dual-channel portable capillary electrophoresis instrument
    Koenka, Israel Joel
    Kung, Nina
    Kuban, Pavel
    Chwalek, Thomas
    Furrer, Gerhard
    Wehrli, Bernhard
    Muller, Beat
    Hauser, Peter C.
    ELECTROPHORESIS, 2016, 37 (17-18) : 2368 - 2375
  • [22] Determination of nitrophenols of environment by dual-electrode and dual-channel electrochemical detection of capillary electrophoresis with polyvinylpyrrolidone modified carbon paste electrode
    Yang, BY
    Mo, JY
    Lai, R
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2005, 26 (02): : 227 - 230
  • [23] Dual-channel capillary electrophoresis for simultaneous determination of cations and anions
    Opekar, Frantisek
    Tuma, Petr
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1446 : 158 - 163
  • [24] A high performance polycarbonate CE microchip with integrated three electrode system for end-channel amperometric detection
    Wang, Yu-Rong
    Chen, Heng-Wu
    He, Qiao-Hong
    Soper, Steven A.
    PROCEEDINGS OF THE FIRST SHENYANG INTERNATIONAL COLLOQUIUM ON MICROFLUIDICS, 2007, : 173 - 176
  • [25] Microchip capillary electrophoresis with an end-channel amperometric detector and its preliminary application
    Wu, YY
    Qu, F
    Lin, JM
    CHINESE JOURNAL OF CHEMISTRY, 2005, 23 (02) : 155 - 159
  • [26] Pyrolyzed photoresist carbon electrodes for microchip electrophoresis with dual-electrode amperometric detection
    Fischer, DJ
    Vandaveer, WR
    Grigsby, RJ
    Lunte, SM
    ELECTROANALYSIS, 2005, 17 (13) : 1153 - 1159
  • [27] Multiple-point electrochemical detection for a dual-channel hybrid PDMS-glass microchip electrophoresis device
    Castano-Alvarez, Mario
    Fernandez-la-Vilia, Ana
    Pozo-Ayuso, Diego F.
    Teresa Fernandez-Abedul, Maria
    Costa-Garcia, Agustin
    ELECTROPHORESIS, 2009, 30 (19) : 3372 - 3380
  • [28] Determination of urine catecholamines by capillary electrophoresis with dual-electrode amperometric detection
    Chen, D
    Zhan, DZ
    Cheng, CW
    Liu, AC
    Chen, C
    JOURNAL OF CHROMATOGRAPHY B, 2001, 750 (01): : 33 - 39
  • [30] A new dual-electrode and multi-channel electrochemical detection system for capillary electrophoresis
    Yang, BY
    Mo, JY
    Lai, R
    CHINESE CHEMICAL LETTERS, 2004, 15 (04) : 439 - 442