Nanoband electrode for high-performance in-channel amperometric detection in dual-channel microchip capillary electrophoresis

被引:19
作者
Chen, Chuanpin [1 ]
Teng, Wei [1 ]
Hahn, Jong Hoon [1 ]
机构
[1] Pohang Univ Sci & Technol, BK Sch Mol Sci, Dept Chem, Pohang 790784, South Korea
关键词
Capillary electrophoresis; Dual-channel; Electrochemical detection; In-channel detection; Microchip; BAND ELECTRODES; FARADAIC ELECTROCHEMISTRY; MICROELECTRODE ARRAYS; NANOELECTRODE ARRAYS; FABRICATION; ULTRAMICROELECTRODES; POLY(DIMETHYLSILOXANE); MICROCYLINDER; VOLTAMMETRY; DIMENSIONS;
D O I
10.1002/elps.201000661
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A nanoband electrode detector integrated with a dual-channel polydimethylsiloxane microchip is proposed for in-channel amperometric detection in microchip capillary electrophoresis. Gold nanoband electrodes, which were fabricated on SU-8 substrates with a 100-nm-width gold layer, were introduced into the dual-channel microchip to be an electrochemical detector. Due to the nano-sized width of the detector, the noise of the amperometric detection was significantly reduced, and a high separation resolution was achieved for monitoring the analytes. The detection sensitivity of the system was improved by high signal-to-noise ratio, and a low detection limit on microchip was obtained for p-aminophenol (2.09 nM). Because of the high resolution in measuring half-peak width, the plate number that is used to evaluate the separation efficiency was 1.5-fold higher than that using 50-mu m-width electrochemical detector. The effect of sample injection time and data acquisition time on separation efficiency was investigated, and an attractive separation efficiency was achieved with a plate number up to 17 500.
引用
收藏
页码:838 / 843
页数:6
相关论文
共 38 条
[31]   DIFFUSIONAL TRANSPORT TO NANOSCOPIC BAND ELECTRODES [J].
SEIBOLD, JD ;
SCOTT, ER ;
WHITE, HS .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 264 (1-2) :281-289
[32]   POLY(3-METHYLTHIOPHENE)-COATED ELECTRODES - OPTICAL AND ELECTRICAL-PROPERTIES AS A FUNCTION OF REDOX POTENTIAL AND AMPLIFICATION OF ELECTRICAL AND CHEMICAL SIGNALS USING POLY(3-METHYLTHIOPHENE)-BASED MICROELECTROCHEMICAL TRANSISTORS [J].
THACKERAY, JW ;
WHITE, HS ;
WRIGHTON, MS .
JOURNAL OF PHYSICAL CHEMISTRY, 1985, 89 (23) :5133-5140
[33]   NANOBAND ELECTRODES FOR ELECTROCHEMICAL STRIPPING MEASUREMENTS DOWN TO THE ATTOMOLE RANGE [J].
WANG, JY ;
RONGRONG, X ;
BAOMIN, T ;
WANG, JY ;
RENSCHLER, CL ;
WHITE, CA .
ANALYTICA CHIMICA ACTA, 1994, 293 (1-2) :43-48
[34]   Zeptomole voltammetric detection and electron-transfer rate measurements using platinum electrodes of nanometer dimensions [J].
Watkins, JJ ;
Chen, JY ;
White, HS ;
Abruña, HD ;
Maisonhaute, E ;
Amatore, C .
ANALYTICAL CHEMISTRY, 2003, 75 (16) :3962-3971
[35]   ELECTROANALYTICAL PROPERTIES OF BAND ELECTRODES OF SUBMICROMETER WIDTH [J].
WEHMEYER, KR ;
DEAKIN, MR ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1985, 57 (09) :1913-1916
[36]   Capillary electrophoresis chips with integrated electrochemical detection [J].
Woolley, AT ;
Lao, KQ ;
Glazer, AN ;
Mathies, RA .
ANALYTICAL CHEMISTRY, 1998, 70 (04) :684-688
[37]  
Zoski CG, 2002, ELECTROANAL, V14, P1041, DOI 10.1002/1521-4109(200208)14:15/16<1041::AID-ELAN1041>3.0.CO
[38]  
2-8