Nanoband electrode for high-performance in-channel amperometric detection in dual-channel microchip capillary electrophoresis

被引:19
|
作者
Chen, Chuanpin [1 ]
Teng, Wei [1 ]
Hahn, Jong Hoon [1 ]
机构
[1] Pohang Univ Sci & Technol, BK Sch Mol Sci, Dept Chem, Pohang 790784, South Korea
关键词
Capillary electrophoresis; Dual-channel; Electrochemical detection; In-channel detection; Microchip; BAND ELECTRODES; FARADAIC ELECTROCHEMISTRY; MICROELECTRODE ARRAYS; NANOELECTRODE ARRAYS; FABRICATION; ULTRAMICROELECTRODES; POLY(DIMETHYLSILOXANE); MICROCYLINDER; VOLTAMMETRY; DIMENSIONS;
D O I
10.1002/elps.201000661
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A nanoband electrode detector integrated with a dual-channel polydimethylsiloxane microchip is proposed for in-channel amperometric detection in microchip capillary electrophoresis. Gold nanoband electrodes, which were fabricated on SU-8 substrates with a 100-nm-width gold layer, were introduced into the dual-channel microchip to be an electrochemical detector. Due to the nano-sized width of the detector, the noise of the amperometric detection was significantly reduced, and a high separation resolution was achieved for monitoring the analytes. The detection sensitivity of the system was improved by high signal-to-noise ratio, and a low detection limit on microchip was obtained for p-aminophenol (2.09 nM). Because of the high resolution in measuring half-peak width, the plate number that is used to evaluate the separation efficiency was 1.5-fold higher than that using 50-mu m-width electrochemical detector. The effect of sample injection time and data acquisition time on separation efficiency was investigated, and an attractive separation efficiency was achieved with a plate number up to 17 500.
引用
收藏
页码:838 / 843
页数:6
相关论文
共 42 条
  • [1] Enhanced aminophenols monitoring using in-channel amperometric detection with dual-channel microchip capillary electrophoresis
    Chuanpin Chen
    Jong Hoon Hahn
    Environmental Chemistry Letters, 2011, 9 : 491 - 497
  • [2] Enhanced aminophenols monitoring using in-channel amperometric detection with dual-channel microchip capillary electrophoresis
    Chen, Chuanpin
    Hahn, Jong Hoon
    ENVIRONMENTAL CHEMISTRY LETTERS, 2011, 9 (04) : 491 - 497
  • [3] Evaluation of in-channel amperometric detection using a dual-channel microchip electrophoresis device and a two-electrode potentiostat for reverse polarity separations
    Meneses, Diogenes
    Gunasekara, Dulan B.
    Pichetsurnthorn, Pann
    da Silva, Jose A. F.
    de Abreu, Fabiane C.
    Lunte, Susan M.
    ELECTROPHORESIS, 2015, 36 (03) : 441 - 448
  • [4] A gold nanoparticle-modified indium tin oxide microelectrode for in-channel amperometric detection in dual-channel microchip electrophoresis
    Zhu, Gangzhi
    Song, Qianhui
    Liu, Wenfang
    Yan, Xingxing
    Xiao, Jian
    Chen, Chuanpin
    ANALYTICAL METHODS, 2017, 9 (29) : 4319 - 4326
  • [5] In-channel amperometric detection for microchip electrophoresis using a wireless isolated potentiostat
    Gunasekara, Dulan B.
    Hulvey, Matthew K.
    Lunte, Susan M.
    ELECTROPHORESIS, 2011, 32 (08) : 832 - 837
  • [6] Low electric field DNA separation and in-channel amperometric detection by microchip capillary electrophoresis
    Ghanim, Motasem Hilmi
    Najimudin, Nazalan
    Ibrahim, Kamarulazizi
    Abdullah, Mohd Zaid
    IET NANOBIOTECHNOLOGY, 2014, 8 (02) : 77 - 82
  • [7] Dual-channel Microchip Electrophoresis with Amperometric Detection System for Rapid Analysis of Cefoperazone and Sulbactam
    Tan, Yan
    Song, Qianhui
    Liu, Wenfang
    Li, Ming
    Xiao, Jian
    Chen, Chuanpin
    ANALYTICAL SCIENCES, 2019, 35 (10) : 1103 - 1109
  • [8] In-channel indirect amperometric detection of nonelectroactive anions for electrophoresis on a poly(dimethylsiloxane) microchip
    Xu, JJ
    Peng, Y
    Bao, N
    Xia, XH
    Chen, HY
    ELECTROPHORESIS, 2005, 26 (19) : 3615 - 3621
  • [9] In-channel simplified decoupler with renewable electrochemical detection for microchip capillary electrophoresis
    Lin, Kuan-Wen
    Huang, Yan-Kai
    Su, Hsiu-Li
    Hsieh, You-Zung
    ANALYTICA CHIMICA ACTA, 2008, 619 (01) : 115 - 121
  • [10] Multiple-point electrochemical detection for a dual-channel hybrid PDMS-glass microchip electrophoresis device
    Castano-Alvarez, Mario
    Fernandez-la-Vilia, Ana
    Pozo-Ayuso, Diego F.
    Teresa Fernandez-Abedul, Maria
    Costa-Garcia, Agustin
    ELECTROPHORESIS, 2009, 30 (19) : 3372 - 3380