A Mobile Gait Monitoring System for Abnormal Gait Diagnosis and Rehabilitation: A Pilot Study for Parkinson Disease Patients

被引:48
作者
Bae, Joonbum [1 ]
Kong, Kyoungchul [2 ]
Byl, Nancy [3 ]
Tomizuka, Masayoshi [1 ]
机构
[1] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
[2] Sogang Univ, Dept Mech Engn, Seoul 121742, South Korea
[3] Univ Calif San Francisco, Dept Phys Therapy & Rehabil Sci, San Francisco, CA 94122 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2011年 / 133卷 / 04期
关键词
GROUND REACTION FORCE; PRESSURE MEASUREMENT; TERMINATION; COMPONENT; PATTERNS; DEVICE;
D O I
10.1115/1.4003525
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Conventional gait rehabilitation treatment does not provide quantitative information on abnormal gait kinematics, and the match of the intervention strategy to the underlying clinical presentation may be limited by clinical expertise and experience. Also the effect of rehabilitation treatment may be reduced as the rehabilitation treatment is achieved only in a clinical setting. In this paper, a mobile gait monitoring system (MGMS) is proposed for the diagnosis of abnormal gait and rehabilitation. The proposed MGMS consists of Smart Shoes and a microsignal processor with a touch screen display. It monitors patients' gait by observing the ground reaction force (GRF) and the center of GRF, and analyzes the gait abnormality. Since visual feedback about patients' GRFs and normal GRF patterns are provided by the MGMS, patients can practice the rehabilitation treatment by trying to follow the normal GRF patterns without restriction of time and place. The gait abnormality proposed in this paper is defined by the deviation between the patient's GRFs and normal GRF patterns, which are constructed as GRF bands. The effectiveness of the proposed gait analysis methods with the MGMS has been verified by preliminary trials with patients suffering from gait disorders. [DOI: 10.1115/1.4003525]
引用
收藏
页数:11
相关论文
共 38 条
[1]  
[Anonymous], STAT PARK DIS
[2]  
[Anonymous], Stroke Statistics
[3]  
BAE J, 2008, THESIS U CALIFORNIA
[4]  
BAE J, 2010, IEEE ASME INT C ADV, pN1362
[5]   Gait analysis using a shoe-integrated wireless sensor system [J].
Bamberg, Stacy J. Morris ;
Benbasat, Ari Y. ;
Scarborough, Donna Moxley ;
Krebs, David E. ;
Paradiso, Joseph A. .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2008, 12 (04) :413-423
[6]  
BERG KO, 1992, CAN J PUBLIC HEALTH, V83, pS7
[7]   Comparison of an in-shoe pressure measurement device to a force plate: concurrent validity of center of pressure measurements [J].
Chesnin, KJ ;
Selby-Silverstein, L ;
Besser, MP .
GAIT & POSTURE, 2000, 12 (02) :128-133
[8]   Use of pressure insoles to calculate the complete ground reaction forces [J].
Forner Cordero, A ;
Koopman, HJFM ;
van der Helm, FCT .
JOURNAL OF BIOMECHANICS, 2004, 37 (09) :1427-1432
[9]   Rehabilitation of balance in two patients with cerebellar dysfunction [J].
GillBody, KM ;
Popat, RA ;
Parker, SW ;
Krebs, DE .
PHYSICAL THERAPY, 1997, 77 (05) :534-552
[10]  
HAYASHI T, 2005, IEEE RSJ INT C INT R, P3063, DOI DOI 10.1109/IROS.2005.1545505