Small-spot intensity-modulated proton therapy and volumetric-modulated arc therapies for patients with locally advanced non-small-cell lung cancer: A dosimetric comparative study

被引:37
|
作者
Liu, Chenbin [1 ]
Sio, Terence T. [1 ]
Deng, Wei [1 ]
Shan, Jie [2 ]
Daniels, Thomas B. [1 ]
Rule, William G. [1 ]
Lara, Pedro R. [1 ]
Korte, Shawn M. [1 ]
Shen, Jiajian [1 ]
Ding, Xiaoning [1 ]
Schild, Steven E. [1 ]
Bues, Martin [1 ]
Liu, Wei [1 ]
机构
[1] Mayo Clin, Dept Radiat Oncol, Phoenix, AZ 85013 USA
[2] Arizona State Univ, Dept Biomed Informat, Tempe, AZ USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2018年 / 19卷 / 06期
关键词
intensity-modulated proton therapy; interplay effects; lung cancer; volumetric-modulated arc therapy; TREATMENT UNCERTAINTIES; ROBUST OPTIMIZATION; RESPIRATORY MOTION; BREATHING MOTION; INTERPLAY; IMPACT; DELIVERY; STAGE; RADIOTHERAPY; 4D;
D O I
10.1002/acm2.12459
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To compare dosimetric performance of volumetric-modulated arc therapy (VMAT) and small-spot intensity-modulated proton therapy for stage III non-small-cell lung cancer (NSCLC). Methods and Materials A total of 24 NSCLC patients were retrospectively reviewed; 12 patients received intensity-modulated proton therapy (IMPT) and the remaining 12 received VMAT. Both plans were generated by delivering prescription doses to clinical target volumes (CTV) on averaged 4D-CTs. The dose-volume-histograms (DVH) band method was used to quantify plan robustness. Software was developed to evaluate interplay effects with randomized starting phases of each field per fraction. DVH indices were compared using Wilcoxon rank sum test. Results Compared with VMAT, IMPT delivered significantly lower cord D-max, heart D-mean, and lung V-5 Gy[RBE] with comparable CTV dose homogeneity, and protection of other OARs. In terms of plan robustness, the IMPT plans were statistically better than VMAT plans in heart D-mean, but were statistically worse in CTV dose coverage, cord D-max, lung D-mean, and V-5 Gy[RBE]. Other DVH indices were comparable. The IMPT plans still met the standard clinical requirements with interplay effects considered. Conclusions Small-spot IMPT improves cord, heart, and lung sparing compared to VMAT and achieves clinically acceptable plan robustness at least for the patients included in this study with motion amplitude less than 11 mm. Our study supports the usage of IMPT to treat some lung cancer patients.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 50 条
  • [31] The dosimetric effects of limited elective nodal irradiation in volumetric modulated arc therapy treatment planning for locally advanced non-small cell lung cancer
    Kenamond, Mark C.
    Siochi, R. Alfredo
    Mattes, Malcolm D.
    JOURNAL OF RADIATION ONCOLOGY, 2018, 7 (01) : 45 - 51
  • [32] Optimising Stereotactic Body Radiotherapy for Non-small Cell Lung Cancer with Volumetric Intensity-modulated Arc Therapy-A Planning Study
    Brock, J.
    Bedford, J.
    Partridge, M.
    McDonald, F.
    Ashley, S.
    McNair, H. A.
    Brada, M.
    CLINICAL ONCOLOGY, 2012, 24 (01) : 68 - 75
  • [33] Feasibility of Pencil Beam Scanned Intensity Modulated Proton Therapy in Breath-hold for Locally Advanced Non-Small Cell Lung Cancer
    Gorgisyan, Jenny
    af Rosenschold, Per Munck
    Perrin, Rosalind
    Persson, Gitte F.
    Josipovic, Mirjana
    Belosi, Maria Francesca
    Engelholm, Svend Aage
    Weber, Damien C.
    Lomax, Antony J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (05): : 1121 - 1128
  • [34] To study the impact of different optimization methods on intensity-modulated radiotherapy and volumetric-modulated arc therapy plans for hip prosthesis patients
    Singh, Pawan Kumar
    Tripathi, Deepak
    Singh, Sukhvir
    Bhushan, Manindra
    Kumar, Lalit
    Raman, Kothanda
    Barik, Soumitra
    Kumar, Gourav
    Shukla, Sushil Kumar
    Gairola, Munish
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (03) : 262 - 269
  • [35] A dosimetric comparison of three-dimensional conformal radiotherapy, volumetric-modulated arc therapy, and dynamic conformal arc therapy in the treatment of non-small cell lung cancer using stereotactic body radiotherapy
    Rauschenbach, Bradley M.
    Mackowiak, Luke
    Malhotra, Harish K.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (05): : 147 - 161
  • [36] Intensity-Modulated Radiotherapy versus 3-Dimensional Conformal Radiotherapy Strategies for Locally Advanced Non-Small-Cell Lung Cancer
    Selek, Ugur
    Bolukbasi, Yasemin
    Welsh, James W.
    Topkan, Erkan
    BALKAN MEDICAL JOURNAL, 2014, 31 (04) : 286 - 294
  • [37] Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer
    Martin, Jeffrey M.
    Handorf, Elizabeth A.
    Price, Robert A.
    Cherian, George
    Buyyounouski, Mark K.
    Chen, David Y.
    Kutikov, Alexander
    Johnson, Matthew E.
    Ma, Chung-Ming Charlie
    Horwitz, Eric M.
    MEDICAL DOSIMETRY, 2015, 40 (03) : 186 - 189
  • [38] Dosimetric comparison of single-arc/partial-arc volumetric modulated arc therapy and intensity-modulated radiotherapy for peripheral and central lung cancer
    Akcay, Melek
    Etiz, Durmus
    Duruer, Kerem
    Bozdogan, Ozge
    Ozen, Alaattin
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (01) : 80 - 87
  • [39] Learning curve of lung dose optimization in intensity-modulated radiotherapy for locally advanced non-small cell lung cancer
    Igari, Mitsunobu
    Abe, Takanori
    Iino, Misaki
    Saito, Satoshi
    Aoshika, Tomomi
    Ryuno, Yasuhiro
    Ohta, Tomohiro
    Hirai, Ryuta
    Kumazaki, Yu
    Noda, Shin-ei
    Kato, Shingo
    THORACIC CANCER, 2023, 14 (26) : 2642 - 2647
  • [40] INTENSITY-MODULATED PROTON THERAPY REDUCES THE DOSE TO NORMAL TISSUE COMPARED WITH INTENSITY-MODULATED RADIATION THERAPY OR PASSIVE SCATTERING PROTON THERAPY AND ENABLES INDIVIDUALIZED RADICAL RADIOTHERAPY FOR EXTENSIVE STAGE IIIB NON-SMALL-CELL LUNG CANCER: A VIRTUAL CLINICAL STUDY
    Zhang, Xiaodong
    Li, Yupeng
    Pan, Xiaoning
    Li Xiaoqiang
    Mohan, Radhe
    Komaki, Ritsuko
    Cox, James D.
    Chang, Joe Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (02): : 357 - 366