Characteristics of the neutron/X-ray tomography system at the SANRAD facility in South Africa

被引:37
作者
de Beer, FC [1 ]
机构
[1] Nucl Technol Div, ZA-0001 Pretoria, South Africa
关键词
SAFARI-1; neutron tomography; NDE testing;
D O I
10.1016/j.nima.2005.01.003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Through collaboration with the NEUTRA-facility at the Paul Scherrer Institute (PSI), Switzerland, a turnkey tomography system was designed specifically for the beam geometry at the South African Neutron Radiography (SANRAD) facility, located on the beam port floor of the SAFARI-1 nuclear research reactor and operated by Necsa. The new system is currently being extensively utilized in both 2D and 3D mode for various applications in general industry and institutional activities. The basic performance characteristics of its 3D tomography capability in a neutron and X-ray configuration are presented with the aid of several case studies. An X-ray source has also been commissioned to further diversify the capabilities of the facility. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 3 条
  • [1] DEBEER FC, 2000, NONDESTR TEST EVAL, V16, P163
  • [2] RIVERS M, IDL BASED TOMOGRAPHY
  • [3] 3D VOLUME RENDERING