Functional Renal Imaging: New Trends in Radiology and Nuclear Medicine

被引:25
作者
Durand, Emmanuel [1 ]
Chaumet-Riffaud, Philippe [1 ]
Grenier, Nicolas [2 ]
机构
[1] Univ Paris Sud, F-94275 Le Kremlin Bicetre, France
[2] Grp Hosp Pellegrin, Serv Imagerie Diagnost & Intervent Adulte, Bordeaux, France
关键词
NEPHROGENIC SYSTEMIC FIBROSIS; GLOMERULAR-FILTRATION-RATE; CONTRAST-INDUCED NEPHROPATHY; CHRONIC KIDNEY-DISEASE; MAGNETIC-RESONANCE; COMPUTED-TOMOGRAPHY; BLOOD-FLOW; RISK; GADOLINIUM; AGENTS;
D O I
10.1053/j.semnuclmed.2010.08.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this work is to compare the characteristics of various techniques for functional renal imaging, with a focus on nuclear medicine and magnetic resonance imaging. Even with low spatial resolution and rather poor signal-to-noise ratio, classical nuclear medicine has the advantage of linearity and good sensitivity. It remains the gold standard technique for renal relative functional assessment. Technetium-99m (Tc-99m)-labeled diethylenetriamine penta-acetate remains the reference glomerular tracer. Tubular tracers have been improved: I-123- or I-131-hippuran, Tc-99m-MAG3 and, recently, Tc-99m-nitrilotriacetic acid. However, advancement in molecular imaging has not produced a groundbreaking tracer. Renal magnetic resonance imaging with classical gadolinated tracers probably has potential in this domain but has a lack of linearity and, therefore, its value still needs evaluation. Moreover, the advent of nephrogenic systemic fibrosis has delayed its expansion. Other developments, such as diffusion or blood oxygen level-dependent imaging, may have a role in the future. The other modalities have a limited role in clinical practice for functional renal imaging. Semin Nucl Med 41:61-72 (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:61 / 72
页数:12
相关论文
共 70 条
  • [31] Reproducibility of a single-sample method for Tc-99(m)-MAG3 clearance under clinical conditions
    Kotzerke, J
    Glatz, S
    Grillenberger, K
    Kleinschmidt, K
    Reske, SN
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 1997, 18 (04) : 352 - 357
  • [32] NSF Prevention in Clinical Practice: Summary of Recommendations and Guidelines in the United States, Canada, and Europe
    Leiner, Tim
    Kucharczyk, Walter
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (06) : 1357 - 1363
  • [33] Sodium MRI of the human kidney at 3 tesla
    Maril, Nimrod
    Rosen, Yael
    Reynolds, Glenn H.
    Ivanishev, Alex
    Ngo, Long
    Lenkinski, Robert E.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1229 - 1234
  • [34] How accurate is dynamic contrast-enhanced MRI in the assessment of renal glomerular filtration rate?: A critical appraisal
    Mendichovszky, Iosif
    Pederson, Michael
    Frokiaer, Jorgen
    Dissing, Thomas
    Grenier, Nicolas
    Anderson, Peter
    McHugh, Kieran
    Yang, Qing
    Gordon, Isky
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 925 - 931
  • [35] Organic nanodots for multiphotonics: synthesis and photophysical studies
    Mongin, Olivier
    Pla-Quintana, Anna
    Terenziani, Francesca
    Drouin, Delphine
    Le Droumaguet, Celine
    Caminade, Anne-Marie
    Majoral, Jean-Pierre
    Blanchard-Desce, Mireille
    [J]. NEW JOURNAL OF CHEMISTRY, 2007, 31 (07) : 1354 - 1367
  • [36] Technetium-99m-EC and other potential new agents in renal nuclear medicine
    Moran, JK
    [J]. SEMINARS IN NUCLEAR MEDICINE, 1999, 29 (02) : 91 - 101
  • [38] MULLER MF, 1994, RADIOLOGY, V193, P711
  • [39] Frequency of serum creatinine changes in the absence of iodinated contrast material: Implications for studies of contrast nephrotoxicity
    Newhouse, Jeffrey H.
    Kho, David
    Rao, Qasim A.
    Starren, Justin
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (02) : 376 - 382
  • [40] Mechanism of NSF: New Evidence Challenging the Prevailing Theory
    Newton, Ben B.
    Jimenez, Sergio A.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (06) : 1277 - 1283