Performance comparison between solid phase extraction and magnetic carbon nanotubes facilitated dispersive-micro solid phase extractions (Mag-CNTs/d-μSPE) of a cyanide metabolite in biological samples using GC-MS

被引:4
作者
Li, Sun Yi [1 ]
Petrikovics, Ilona [2 ]
Yu, Jorn [1 ]
机构
[1] Sam Houston State Univ, Dept Forens Sci, Huntsville, TX 77341 USA
[2] Sam Houston State Univ, Dept Chem, Huntsville, TX 77341 USA
关键词
Magnetic carbon nanotubes (Mag-CNTs); Dispersive-micro solid phase extraction; Cyanide metabolite; Surface modification; Functionalization; Solid phase extraction; 2-Aminothiazoline-4-carboxylic acid (ATCA); Derivatization; Death investigation; LIQUID CHROMATOGRAPHY-QUADRUPOLE/TIME; 2-AMINOTHIAZOLINE-4-CARBOXYLIC ACID; WHOLE-BLOOD; URINE; EXPOSURE; SORBENT; MARKER; MICROEXTRACTION; QUANTIFICATION; FENTANYL;
D O I
10.1186/s40543-021-00296-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dispersive-micro solid phase extraction (d-mu SPE) has gained increasing attention due to its convenience, effectiveness, and flexibility for sorbent selection. Among a various selection of materials, magnetic carbon nanotubes (Mag-CNTs) is a promising d-mu SPE sorbent with excellent separation efficiency in addition to its high surface area and adsorption capability. In this work, two different surface-modified Mag-CNTs, Mag-CNTs-COOH and Mag-CNTs-SO3H, were developed to facilitate d-mu SPE (Mag-CNTs/d-mu SPE). The cyanide metabolite, 2-aminothiazoline-4-carboxylic acid (ATCA), was selected to evaluate their extraction performance using gas chromatography-mass spectrometry (GC-MS) analysis. The Mag-CNTs-COOH enabled a one-step derivatization/desorption approach in the workflow; therefore, a better overall performance was achieved. Compared to the Mag-CNTs-SO3H/d-mu SPE and SPE workflow, the one-step desorption/derivatization approach improved the overall extraction efficiency and reduced solvent consumption and waste production. Both Mag-CNTs/d-mu SPE workflows were validated according to ANSI/ASB 036 guidelines and showed excellent analytical performances. The limit of detection (LOD) and limit of quantitation (LOQ) of ATCA in synthetic urine were 5 and 10 ng/mL, respectively, and that in bovine blood were achieved at 10 and 60 ng/mL. The SPE method's LOD and LOQ were also determined at 1 and 25 ng/mL in bovine blood samples. The Mag-CNTs/d-mu SPE methods demonstrated great potential to extract polar and ionic metabolites from biological matrices. The extraction processes of ATCA described in this work can provide an easier-to-adopt procedure for potential routine forensic testing of the stable biomarker in cyanide poisoning cases, particularly for those cases where the cyanide detection window has passed.
引用
收藏
页数:12
相关论文
共 49 条
[1]   Nanomaterials as sorbents for sample preparation in bioanalysis: A review [J].
Ahmadi, Mazaher ;
Elmongy, Hatem ;
Madrakian, Tayyebeh ;
Abdel-Rehim, Mohamed .
ANALYTICA CHIMICA ACTA, 2017, 958 :1-21
[2]  
[Anonymous], 1999, J AM CHEM SOC
[3]  
[Anonymous], 2019, RES AG TRANSF SEP SC, DOI DOI 10.17226/25421
[4]  
Ansell M, 1970, J Forensic Med, V17, P148
[5]  
ANSI/ASB, 2019, 036 ANSIASB
[6]   INVITRO PRODUCTION OF CYANIDE IN NORMAL HUMAN-BLOOD AND INFLUENCE OF THIOCYANATE AND STORAGE TEMPERATURE [J].
BALLANTYNE, B .
CLINICAL TOXICOLOGY, 1977, 11 (02) :173-193
[7]   DETERMINATION OF 2-IMINOTHIAZOLIDINE-4-CARBOXYLIC ACID [J].
BRADHAM, LS ;
CATSIMPOOLAS, N ;
WOOD, JL .
ANALYTICAL BIOCHEMISTRY, 1965, 11 (02) :230-+
[8]   A case of acute intoxication due to combined use of fentanyl and 3,4-dichloro-N-[2-( dimethylamino)cyclohexyl]-N-methylbenzamide (U-47700) [J].
Coopman, Vera ;
Blanckaert, Peter ;
Van Parys, Geert ;
Van Calenbergh, Serge ;
Cordonnier, Jan .
FORENSIC SCIENCE INTERNATIONAL, 2016, 266 :68-72
[9]   Evaluation of the QuEChERS and magnetic micro dispersive solid-phase extraction of brominated flame retardants in red fruits with determination by GC/MS [J].
Fernandes, Virginia Cruz ;
Freitas, Maria ;
Pacheco, Joao G. ;
Domingues, Valentina Fernandes ;
Delerue-Matos, Cristina .
FOOD CHEMISTRY, 2020, 309
[10]   Magnetic dispersive micro solid-phase extraction and gas chromatography determination of organophosphorus pesticides in strawberries [J].
Fernandes, Virginia Cruz ;
Freitas, Maria ;
Pacheco, Joao P. G. ;
Oliveira, Jose Maria ;
Domingues, Valentina Fernandes ;
Delerue-Matos, Cristina .
JOURNAL OF CHROMATOGRAPHY A, 2018, 1566 :1-12