Incorporating earth fault location in management-control scheme for distribution networks

被引:14
作者
Elsadd, Mahmoud A. [1 ]
Elkalashy, Nagy I. [1 ]
Kawady, Tamer A. [1 ]
Taalab, Abdel-Maksoud I. [1 ]
Lehtonen, Matti [2 ]
机构
[1] Minoufiya Univ, Fac Engn, Dept Elect Engn, Shibin Al Kawm 32511, Egypt
[2] Aalto Univ, Sch Elect Engn, Dept Elect Engn, Espoo, Finland
关键词
fault location; power distribution faults; power distribution control; substation protection; IEEE standards; power system management; distribution network; earth fault location computation; fault management-control scheme; control signal; lateral-panel substation; faulted section isolator; service restoration; feeder primary substation; pure fault circuit; phase-to-ground fault; phase-to-phase-to-ground fault; distributed generation; distribution system; transformer connection; transformer load tap; IEEE 33-bus automated feeder; POWER DISTRIBUTION-SYSTEMS; GENERATION;
D O I
10.1049/iet-gtd.2015.1143
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study integrates earth fault location computation with fault management-control schemes for distribution networks. To realise this target, a panel substation is located at the lateral outlet. The faulted section is identified precisely via a fault-location algorithm. Then, isolating the faulted section is accomplished through control signals between the lateral-panel substation and the faulted section isolators. The service restoration is achieved by a direct communication between the lateral-panel substation and the feeder primary substation. The proposed fault-location algorithm is based on the pure fault circuit with the initial condition of the earth fault using the measurements at each lateral panel. For phase-to-ground fault, the initial condition is the series connection for the sequence networks from the fault point. For phase-to-phase-to-ground fault, the initial condition is that the summation of the sequence currents at the fault point is equal to zero. The proposed fault-location algorithm is, therefore, suitable for equipping distribution systems with distributed generation. Moreover, it is applicable for earthed or unearthed networks with all possibilities of transformer connection and load taps. For investigation purposes, simulation tests are performed using the IEEE 33-bus automated feeder example. The simulation test results corroborated the efficacy of the proposed fault management system.
引用
收藏
页码:2389 / 2398
页数:10
相关论文
共 22 条
  • [1] [Anonymous], 2003, WG03 CIRED
  • [2] [Anonymous], 2003, GRID 2030 NAT VIS EL
  • [3] [Anonymous], 2013, Int. J. Electr. Eng. Inform.
  • [4] [Anonymous], 2010, C2 PSRCWG IEEE POW S
  • [5] Fault diagnosis in distribution networks with distributed generation
    El-Zonkoly, A. M.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (07) : 1482 - 1490
  • [6] A FAULT LOCATION TECHNIQUE FOR RURAL DISTRIBUTION FEEDERS
    GIRGIS, AA
    FALLON, CM
    LUBKEMAN, DL
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1993, 29 (06) : 1170 - 1175
  • [7] Transmission line fault detection and localisation methodology using PMU measurements
    Gopakumar, Pathirikkat
    Reddy, Maddikara Jaya Bharata
    Mohanta, Dusmanta Kumar
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (11) : 1033 - 1042
  • [8] Hazim H., 2007, J APPL SCI, V7, P3736, DOI [10.3923/jas.2007.3736.3742, DOI 10.3923/JAS.2007.3736.3742]
  • [9] Holkar V., 2012, IOSR J ELECT ELECT E, V2, P42
  • [10] Smart distribution system volt/VAR control using distributed intelligence and wireless communication
    Ibrahim, Michael
    Salama, Magdy M. A.
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (04) : 307 - 318