Fire performance of restrained welded steel box columns

被引:6
作者
Yang, Kuo Chen [1 ]
Yang, Fang Chieh [1 ]
机构
[1] Natl Kaohsiung First Univ Sci & Technol, Dept Construct Engn, Kaohsiung 824, Taiwan
关键词
Welded steel box columns; Fire load; Complete-joint-penetration groove weld; Partial-joint-penetration groove weld; Width-to-thickness ratio; Load ratio; ELEVATED-TEMPERATURES; DESIGN; RESISTANCE;
D O I
10.1016/j.jcsr.2015.01.019
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objectives of this study is to investigate the effect of weld details (CJP or PJP), the load ratios, and the width-to-thickness ratios on the fire performance of unprotected welded steel box columns at 500 degrees C. Upon the experimental works, five column specimens were loaded to their ultimate state at room temperature and ten unprotected column specimens were loaded by steady-state method up to 500 degrees C. In this study it is found that local buckling is the failure mode observed for the column specimen tested either at room temperature or in the fire condition. At 500 degrees C, unprotected CJP steel box columns show superior fire behavior compared to the columns fabricated by PJP which are more susceptible to premature cracking at the corner welds. CJP box columns with non-compact sections and no discernible cracks are able to sustain design loads of 0.8 phi P-n for 2 h under temperature conditions of 500 degrees C. At 500 degrees C, the fire resistance of PJP box columns can be enhanced by decreasing the applied loads and/or the width-to-thickness ratios. But, the fire resistance of steel box columns would be reduced significantly whenever the premature cracks were existed in the corner welds. Based on the result of this study, it is found that CJP box columns would be a better choice than PJP box columns for unprotected steel box columns under 500 degrees C. If CJP is not feasible in practical application and PJP is used instead, it is strongly suggested to design a compact section for those PJP box columns. (c) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:173 / 181
页数:9
相关论文
共 19 条
[1]   Fire design of steel columns: Effects of thermal gradients [J].
Agarwal, Anil ;
Choe, Lisa ;
Varma, Amit H. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 93 :107-118
[2]   Structural performance of rotationally restrained steel columns in fire [J].
Ali, F ;
O'Connor, D .
FIRE SAFETY JOURNAL, 2001, 36 (07) :679-691
[3]  
[Anonymous], 2007, STRUCTURAL STEEL DES
[4]  
[Anonymous], 2003, 13812 CNS
[5]  
Antonio MC, 2001, FIRE SAF J, V36, P679
[6]  
Chang S., 1994, THESIS
[7]   Design of high strength steel columns at elevated temperatures [J].
Chen, Ju ;
Young, Ben .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2008, 64 (06) :689-703
[8]   RESIDUAL-STRESSES IN WELDED JUMBO BOX COLUMNS [J].
CHEN, SJ ;
CHANG, SC .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1993, 25 (03) :201-209
[9]   A simple model for the fire resistance of axially loaded members - Comparison with experimental results [J].
Franssen, JM ;
Schleich, JB ;
Cajot, LG ;
Azpiazu, W .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1996, 37 (03) :175-204
[10]   Alternative approach to buckling of square hollow section steel columns in fire [J].
Kervalishvili, Andrei ;
Talvik, Ivar .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 96 :140-150