Image reconstruction in cardiac interventions using a small flat-panel detector

被引:0
作者
Lauzier, Pascal Theriault [1 ]
Tang, Jie [1 ]
Qi, Zhihua [1 ]
Chen, Guang-Hong [1 ]
机构
[1] Univ Wisconsin Madison, Dept Med Phys, Madison, WI 53704 USA
来源
MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING | 2010年 / 7622卷
关键词
cone-beam computed tomography; cardiac imaging; interior problem; computed tomography; reconstruction algorithms; TRUNCATED HILBERT TRANSFORM; FIELD-OF-VIEW; CONE-BEAM CT; INTERIOR TOMOGRAPHY; PROJECTION DATA; ALGORITHM; BACKPROJECTION; DECOMPOSITION; REGION;
D O I
10.1117/12.844581
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
C-arm CT is used in neurovascular interventions where a large flat panel detector is used to acquire cone-beam projection data. In this case, data truncation problems due to the limited detector size are mild. When the cone beam CT method is applied to cardiac interventions severe data truncation artifacts reduce the clinical utility of the reconstructions. However, accurate reconstruction is still possible given a priori knowledge of the reconstruction values within a small region inside the FOV. Several groups have studied the case of the interior problem where data is truncated from all views. In this paper, we applied these new mathematical discoveries to C-arm cardiac cone-beam CT to demonstrate that accurate image reconstruction may be achieved for cardiac interventions. The method is applied to iteratively reconstruct the image volume such that it satisfies several physical conditions. In this work, the algorithm is applied to data from in-vivo cardiac canine studies collected using a clinical C-arm system. It is demonstrated that the algorithm converges well to the reconstruction values of non-truncated data reconstructed using the FDK algorithm. Furthermore, proper convergence is achieved by using only an estimate of the average value within a subregion as a priori information (i.e. the exact value at each pixel in the a priori region need not be known). Two methods for obtaining a priori information are compared.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Flat-panel cone-beam computed tomography for image-guided radiation therapy
    Jaffray, DA
    Siewerdsen, JH
    Wong, JW
    Martinez, AA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05): : 1337 - 1349
  • [32] Clinical Applications of Quantitative Perfusion Imaging with a C-Arm Flat-Panel Detector-A Systematic Review
    Al-Kaylani, Abdallah H. A. Zaid
    Schuurmann, Richte C. L.
    Maathuis, Wouter D.
    Slart, Riemer H. J. A.
    De Vries, Jean-Paul P. M.
    Bokkers, Reinoud P. H.
    DIAGNOSTICS, 2023, 13 (01)
  • [33] The Impact of Cross-Talk in a Flat Panel Detector on CT Image Quality
    Karimi, Seemeen
    Hall, James
    Smith, Jerel A.
    Tringe, Joseph
    IEEE OPEN JOURNAL OF INSTRUMENTATION AND MEASUREMENT, 2023, 2 : 1 - 9
  • [34] Reliability and Usefulness of Intraoperative 3-Dimensional Imaging by Mobile C-Arm With Flat-Panel Detector
    Fujimori, Takahito
    Iwasaki, Motoki
    Nagamoto, Yukitaka
    Kashii, Masafumi
    Takao, Masaki
    Sugiura, Tsuyoshi
    Yoshikawa, Hideki
    CLINICAL SPINE SURGERY, 2017, 30 (01): : E64 - E75
  • [35] Improved radiological imaging of congenital aural atresia using flat-panel volume CT
    Mueller-Graff, Franz-Tassilo
    von Duering, Jan
    Voelker, Johannes
    Al-Tinawi, Fadi
    Hagen, Rudolf
    Neun, Tilmann
    Hackenberg, Stephan
    Rak, Kristen
    HNO, 2024, 72 (SUPPL 2) : 111 - 119
  • [36] Comparing the Image Quality of a Mobile Flat-Panel Computed Tomography and a Multidetector Computed Tomography A Phantom Study
    Neubauer, Jakob
    Voigt, Johannes M.
    Lang, Hannah
    Scheuer, Carsten
    Goerke, Sebastian M.
    Langer, Mathias
    Fiebich, Martin
    Kotter, Elmar
    INVESTIGATIVE RADIOLOGY, 2014, 49 (07) : 491 - 497
  • [37] Novel flat-panel cone-beam CT compared to multi-detector CT for assessment of acute ischemic stroke: A prospective study
    Nicholson, Patrick
    Cancelliere, Nicole M.
    Bracken, John
    Hummel, Erik
    van Nijnatten, Fred
    Withagen, Paul
    van de Haar, Peter
    Hallacoglu, Bertan
    van Vlimmeren, Marijke
    Agid, Ronit
    Krings, Timo
    Pereira, Vitor Mendes
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 138
  • [38] Patient-specific scatter correction for flat-panel detector-based cone-beam CT imaging
    Zhao, Wei
    Brunner, Stephen
    Niu, Kai
    Schafer, Sebastian
    Royalty, Kevin
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03) : 1339 - 1365
  • [39] Technical assessment of 2D and 3D imaging performance of an IGZO-based flat-panel X-ray detector
    Sheth, Niral Milan
    Uneri, Ali
    Helm, Patrick A.
    Zbijewski, Wojciech
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2022, 49 (05) : 3053 - 3066
  • [40] Photon counting-energy integrating hybrid flat panel detector systems for image-guided interventions: an experimental proof-of-concept
    Treb, Kevin
    Haemisch, York
    Ullberg, Christer
    Zhang, Ran
    Li, Ke
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (13)