Image reconstruction in cardiac interventions using a small flat-panel detector

被引:0
|
作者
Lauzier, Pascal Theriault [1 ]
Tang, Jie [1 ]
Qi, Zhihua [1 ]
Chen, Guang-Hong [1 ]
机构
[1] Univ Wisconsin Madison, Dept Med Phys, Madison, WI 53704 USA
来源
MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING | 2010年 / 7622卷
关键词
cone-beam computed tomography; cardiac imaging; interior problem; computed tomography; reconstruction algorithms; TRUNCATED HILBERT TRANSFORM; FIELD-OF-VIEW; CONE-BEAM CT; INTERIOR TOMOGRAPHY; PROJECTION DATA; ALGORITHM; BACKPROJECTION; DECOMPOSITION; REGION;
D O I
10.1117/12.844581
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
C-arm CT is used in neurovascular interventions where a large flat panel detector is used to acquire cone-beam projection data. In this case, data truncation problems due to the limited detector size are mild. When the cone beam CT method is applied to cardiac interventions severe data truncation artifacts reduce the clinical utility of the reconstructions. However, accurate reconstruction is still possible given a priori knowledge of the reconstruction values within a small region inside the FOV. Several groups have studied the case of the interior problem where data is truncated from all views. In this paper, we applied these new mathematical discoveries to C-arm cardiac cone-beam CT to demonstrate that accurate image reconstruction may be achieved for cardiac interventions. The method is applied to iteratively reconstruct the image volume such that it satisfies several physical conditions. In this work, the algorithm is applied to data from in-vivo cardiac canine studies collected using a clinical C-arm system. It is demonstrated that the algorithm converges well to the reconstruction values of non-truncated data reconstructed using the FDK algorithm. Furthermore, proper convergence is achieved by using only an estimate of the average value within a subregion as a priori information (i.e. the exact value at each pixel in the a priori region need not be known). Two methods for obtaining a priori information are compared.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Removal and effects of scatter-glare in cone-beam CT with an amorphous-silicon flat-panel detector
    Poludniowski, G.
    Evans, P. M.
    Kavanagh, A.
    Webb, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (06) : 1837 - 1851
  • [22] ML reconstruction of cone-beam projections acquired by a flat-panel rotational X-ray device
    Pfeiffer, Tim
    Frysch, Robert
    Gugel, Sebastian
    Rose, Georg
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [23] Model-based CBCT scatter correction with dual-layer flat-panel detector
    Zhang, Xin
    Xie, Jixiong
    Tan, Yuhang
    Su, Ting
    Zhu, Jiongtao
    Cui, Han
    Xia, Dongmei
    Zheng, Hairong
    Liang, Dong
    Ge, Yongshuai
    MEDICAL PHYSICS, 2025, 52 (03) : 1500 - 1514
  • [24] Cone-beam computed tomography with a flat-panel imager: Effects of image lag
    Siewerdsen, JH
    Jaffray, DA
    MEDICAL PHYSICS, 1999, 26 (12) : 2635 - 2647
  • [25] Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise
    Tilley, Steven, II
    Siewerdsen, Jeffrey H.
    Stayman, J. Webster
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01) : 296 - 319
  • [26] High-resolution gel dosimetry using flat-panel detector cone-beam computed tomography: Preliminary study
    Huang, Kuo-Ming
    Huang, Tzung-Chi
    Tsai, Chia-Jung
    Lu, Kun-Mu
    Chen, Liang-Kuang
    Wu, Tung-Hsin
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 607 - 609
  • [27] Signal crosstalk correction for flat panel detector based on image deconvolution
    An K.
    Shu H.
    Lu Y.
    Zhou R.
    Wang J.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2023, 44 (07): : 194 - 202
  • [28] Super Resolution Dual-Energy Cone-Beam CT Imaging With Dual-Layer Flat-Panel Detector
    Su, Ting
    Zhu, Jiongtao
    Zhang, Xin
    Tan, Yuhang
    Cui, Han
    Zeng, Dong
    Guo, Jinchuan
    Zheng, Hairong
    Ma, Jianhua
    Liang, Dong
    Ge, Yongshuai
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2024, 43 (02) : 734 - 744
  • [29] Potential applications of flat-panel volumetric CT in morphologic and functional small animal imaging
    Greschus, S
    Kiessling, F
    Lichy, MP
    Moll, J
    Mueller, MM
    Savai, R
    Rose, F
    Ruppert, C
    Günther, A
    Luecke, M
    Fusenig, NE
    Semmler, W
    Traupe, H
    NEOPLASIA, 2005, 7 (08): : 730 - 740
  • [30] Geometric Calibration for Offset Flat-panel CBCT Systems using Projection Matrix
    Van-Giang Nguyen
    2016 INTERNATIONAL CONFERENCE ON ELECTRONICS, INFORMATION, AND COMMUNICATIONS (ICEIC), 2016,