Active droplet-array microfluidics-based chemiluminescence immunoassay for point-of-care detection of procalcitonin

被引:54
作者
Huang, Enqi [1 ]
Huang, Dezhi [1 ]
Wang, Yu [1 ]
Cai, Dongyang [1 ]
Luo, Yanzhang [1 ]
Zhong, Zhimin [2 ]
Liu, Dayu [1 ,2 ,3 ]
机构
[1] South China Univ Technol, Sch Med, Guangzhou 510006, Peoples R China
[2] South China Univ Technol, Guangzhou Peoples Hosp 1, Dept Lab Med, Guangzhou 510180, Peoples R China
[3] Guangdong Engn Technol Res Ctr Microfluid Chip Me, Guangzhou 510180, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Microfluidic; Chemiluminescence; Immunoassay; Point-of-Care; Automation; Diagnosis; AMPLIFICATION STRATEGY; PARTICLE;
D O I
10.1016/j.bios.2021.113684
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The application of conventional chemiluminescence immunoassay (CLIA) in resource-limited settings is limited due to the large apparatus footprint, cumbersome operation and maintenance process, and high consumption of reagents. To address this issue, we developed an active droplet-array (ADA) microfluidics-based CLIA system, which consists of a compact microchip analyzer and microfluidic chips with preloaded reagents. The microfluidic chip contains microslit-connected microchambers, in which all the required reagents were preloaded in water-inoil droplets. The microfluidic chip analyzer can manipulate five microfluidic chips in parallel in a single run. By interacting the microchip with magnetic, thermal, optical mechanisms programmatically, the entire workflow of CLIA can be accomplished in an automated manner. With the proposed CLIA, the detection of procalcitonin (PCT) can be completed in 12 min, with a limit of detection (LOD) of 0.044 ng mL(-1) and a detection range from 0.044 to 100 ng mL(-1). We found a good linear correlation between the microfluidic CLIA and the conventional electrochemiluminescence immunoassay (R-2 =0.98).The microfluidic CLIA has significant advantages over the conventional ELISA in detection sensitivity, dynamic range, instrument size and turnaround time, and can provide more consistent and reliable results than the lateral flow immunoassays. The compact microfluidic system can perform automated and parallelized CLIA in a short turnaround time, and thus well suited to Point-of-Care detection of disease biomarkers.
引用
收藏
页数:9
相关论文
共 26 条
[1]   Chemiluminescence-based detection:: principles and analytical applications in flowing streams and in immunoassays [J].
Baeyens, WRG ;
Schulman, SG ;
Calokerinos, AC ;
Zhao, Y ;
Campaña, AMG ;
Nakashima, K ;
De Keukeleire, D .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) :941-953
[2]   Design and testing of a disposable microfluidic chemiluminescent immunoassay for disease biomarkers in human serum samples [J].
Bhattacharyya, A. ;
Klapperich, C. M. .
BIOMEDICAL MICRODEVICES, 2007, 9 (02) :245-251
[3]   Development of magnetic sensor technologies for point-of-care testing: Fundamentals, methodologies and applications [J].
Cao, Bo ;
Wang, Kan ;
Xu, Hao ;
Qin, Qi ;
Yang, Jinchuan ;
Zheng, Wei ;
Jin, Qinghui ;
Cui, Daxiang .
SENSORS AND ACTUATORS A-PHYSICAL, 2020, 312
[4]   Automated Droplet-Based Microfluidic Platform for Multiplexed Analysis of Biochemical Markers in Small Volumes [J].
Cedillo-Alcantar, Diana F. ;
Han, Yong Duk ;
Choi, Jonghoon ;
Garcia-Cordero, Jose L. ;
Revzin, Alexander .
ANALYTICAL CHEMISTRY, 2019, 91 (08) :5133-5141
[5]  
Cinquanta L, 2017, AUTOIMMUN HIGHLIGHTS, V8, DOI 10.1007/s13317-017-0097-2
[6]   Protein quantification by bicinchoninic acid (BCA) assay follows complex kinetics and can be performed at short incubation times [J].
Cortes-Rios, Javiera ;
Maria Zarate, Ana ;
David Figueroa, Juan ;
Medina, Joaquin ;
Fuentes-Lemus, Eduardo ;
Rodriguez-Fernandez, Maria ;
Aliaga, Margarita ;
Lopez-Alarcon, Camilo .
ANALYTICAL BIOCHEMISTRY, 2020, 608
[7]   Magnetic chemiluminescent immunoassay for human C-reactive protein on the centrifugal microfluidics platform [J].
Czilwik, G. ;
Vashist, S. K. ;
Klein, V. ;
Buderer, A. ;
Roth, G. ;
von Stetten, F. ;
Zengerle, R. ;
Mark, D. .
RSC ADVANCES, 2015, 5 (76) :61906-61912
[8]   A flux-adaptable pump-free microfluidics-based self-contained platform for multiplex cancer biomarker detection [J].
Dai, Bo ;
Yin, Cheng ;
Wu, Jiandong ;
Li, Wei ;
Zheng, Lulu ;
Lin, Francis ;
Han, Xiaodian ;
Fu, Yongfeng ;
Zhang, Dawei ;
Zhuang, Songlin .
LAB ON A CHIP, 2021, 21 (01) :143-153
[9]   A new microchannel capillary flow assay (MCFA) platform with lyophilized chemiluminescence reagents for a smartphone-based POCT detecting malaria [J].
Ghosh, Sthitodhi ;
Aggarwal, Kashish ;
Vinitha, T. U. ;
Thinh Nguyen ;
Han, Jungyoup ;
Ahn, Chong H. .
MICROSYSTEMS & NANOENGINEERING, 2020, 6 (01)
[10]   An automated and portable microfluidic chemiluminescence immunoassay for quantitative detection of biomarkers [J].
Hu, Binfeng ;
Li, Juanjuan ;
Mou, Lei ;
Liu, Yong ;
Deng, Jinqi ;
Qian, Wei ;
Sun, Jiashu ;
Cha, Ruitao ;
Jiang, Xingyu .
LAB ON A CHIP, 2017, 17 (13) :2225-2234