End-wall errors in temperature measurement of external convective heat transfer with Moire deflectometry

被引:3
|
作者
Juste, G. L. [1 ]
Benavides, E. M. [1 ]
机构
[1] Univ Politecn Madrid, E-28040 Madrid, Spain
关键词
Moire deflectometry; Error; Analysis; Heat transfer; Forced convection; External flow; 3-D effects; FIELD; FLAME; SOLIDS;
D O I
10.1016/j.optlaseng.2010.09.009
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Moire deflectometry is a robust and simple optical method that allows obtaining the temperature field in flows with uniform pressure and two-dimensional and axisymmetric flows. Since in real configurations it is not possible to keep exactly the hypothesis of two-dimensional flow, it is necessary to asses this influence. Therefore this work studies a procedure to estimate the errors due to the end-wall and 3-D effects when Moire deflectometry is used for measuring the temperature field of an external convective heat transfer flow with free edges. According to the value of the parameter Gr/Re-2, results show two tendencies. The error in temperature measurement is smaller than 1% for ratios of thermal boundary layer thickness to the test field width lower than 0.4, in turbulent forced convection flows for temperature differences of 40 K. Temperature effects are significative, multiplying the error by two for a temperature difference 50% greater. These results enable researchers to evaluate the errors of this measurement technique associated with the end-wall effect. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:8 / 12
页数:5
相关论文
共 50 条
  • [31] Annual experimental research on convective heat transfer coefficient of exterior surface of building external wall
    Yang, Wen
    Zhu, Xinrong
    Liu, Jiaping
    ENERGY AND BUILDINGS, 2017, 155 : 207 - 214
  • [32] Laminar convective heat transfer of non-Newtonian nanofluids with constant wall temperature
    M. Hojjat
    S. Gh. Etemad
    R. Bagheri
    J. Thibault
    Heat and Mass Transfer, 2011, 47 : 203 - 209
  • [33] Convective heat transfer for incompressible laminar gas flow in micropassage with constant wall temperature
    An Gang
    Li Junming
    Wang Buxuan
    Science in China Series E: Technolgical Science, 2001, 44 (2): : 164 - 169
  • [34] THERMODYNAMIC OPTIMIZATION OF CONVECTIVE HEAT-TRANSFER THROUGH A DUCT WITH CONSTANT WALL TEMPERATURE
    NAG, PK
    MUKHERJEE, P
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1987, 30 (02) : 401 - 405
  • [35] Characterizing the convective wall heat transfer on convoluted shapes in the end-region of an induction machine
    Hettegger, Martin
    Reinbacher-Koestinger, Alice
    Biro, Oszkar
    2012 XXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2012, : 1219 - 1226
  • [36] An adjustment to the standard temperature wall function for CFD modeling of indoor convective heat transfer
    Zhang, Tengfei
    Zhou, Hongbiao
    Wang, Shugang
    BUILDING AND ENVIRONMENT, 2013, 68 : 159 - 169
  • [37] Convective heat transfer for incompressible laminar gas flow in micropassage with constant wall temperature
    安刚
    李俊明
    王补宣
    Science in China(Series E:Technological Sciences), 2001, (02) : 164 - 169
  • [38] Convective heat transfer for incompressible laminar gas flow in micropassage with constant wall temperature
    An, G
    Li, JM
    Wang, BX
    SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2001, 44 (02): : 164 - 169
  • [39] Laminar convective heat transfer of non-Newtonian nanofluids with constant wall temperature
    Hojjat, M.
    Etemad, S. Gh.
    Bagheri, R.
    Thibault, J.
    HEAT AND MASS TRANSFER, 2011, 47 (02) : 203 - 209
  • [40] Unsteady pressure measurement and numerical simulations in an end-wall region of a linear blade cascade
    Flidr, Erik
    Straka, Petr
    Kladrubsky, Milan
    Jelinek, Tomas
    SN APPLIED SCIENCES, 2021, 3 (08):