End-wall errors in temperature measurement of external convective heat transfer with Moire deflectometry

被引:3
|
作者
Juste, G. L. [1 ]
Benavides, E. M. [1 ]
机构
[1] Univ Politecn Madrid, E-28040 Madrid, Spain
关键词
Moire deflectometry; Error; Analysis; Heat transfer; Forced convection; External flow; 3-D effects; FIELD; FLAME; SOLIDS;
D O I
10.1016/j.optlaseng.2010.09.009
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Moire deflectometry is a robust and simple optical method that allows obtaining the temperature field in flows with uniform pressure and two-dimensional and axisymmetric flows. Since in real configurations it is not possible to keep exactly the hypothesis of two-dimensional flow, it is necessary to asses this influence. Therefore this work studies a procedure to estimate the errors due to the end-wall and 3-D effects when Moire deflectometry is used for measuring the temperature field of an external convective heat transfer flow with free edges. According to the value of the parameter Gr/Re-2, results show two tendencies. The error in temperature measurement is smaller than 1% for ratios of thermal boundary layer thickness to the test field width lower than 0.4, in turbulent forced convection flows for temperature differences of 40 K. Temperature effects are significative, multiplying the error by two for a temperature difference 50% greater. These results enable researchers to evaluate the errors of this measurement technique associated with the end-wall effect. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:8 / 12
页数:5
相关论文
共 50 条
  • [21] Spatial-temporal turbulent flow-field and heat transfer behavior in end-wall junctions
    Praisner, TJ
    Seal, CV
    Takmaz, L
    Smith, CR
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 1997, 18 (01) : 142 - 151
  • [22] EXPERIMENTAL-STUDY OF THE ISO-HEAT-TRANSFER-RATE LINES ON THE END-WALL OF A TURBINE CASCADE
    GEORGIOU, DP
    DODARD, M
    RICHARDS, BE
    MECHANICAL ENGINEERING, 1979, 101 (06) : 99 - 99
  • [23] Dynamic model for measurement of convective heat transfer coefficient at external building surfaces
    Ohlsson, K. E. Anders
    Ostin, Ronny
    Grundberg, Staffan
    Olofsson, Thomas
    JOURNAL OF BUILDING ENGINEERING, 2016, 7 : 239 - 245
  • [24] UNSTEADY PRESSURE MEASUREMENT IN AN END-WALL REGION OF A LINEAR BLADE CASCADE
    Flidr, E.
    Kladrubsky, M.
    Jelinek, T.
    TOPICAL PROBLEMS OF FLUID MECHANICS 2020, 2020, : 72 - 81
  • [25] Measurement of temperature and electrons density distribution of atmospheric arc plasma by moire deflectometry technique
    Meidanshahi, Fatemeh Salimi
    Madanipour, Khosro
    Shokri, Babak
    OPTICS AND LASERS IN ENGINEERING, 2013, 51 (04) : 382 - 387
  • [26] The research on exergy transfer of forced convective heat transfer through a duct with constant wall temperature
    Wu, Shuang-ying
    Chen, Yan
    Li, You-rong
    Zeng, Dan-ling
    HT2005: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE 2005, VOL 4, 2005, : 325 - 330
  • [27] Exergy transfer characteristics of forced convective heat transfer through a duct with constant wall temperature
    Wu, Shuang-Ying
    Li, You-Rong
    Chen, Yan
    Xiao, Lan
    ENERGY, 2007, 32 (12) : 2385 - 2395
  • [28] Measurement and calculation of nozzle guide vane end wall heat transfer
    Harvey, N.W.
    Rose, M.G.
    Coupland, J.
    Jones, T.V.
    Journal of Turbomachinery, 1999, 121 (02): : 184 - 190
  • [29] Measurement and calculation of nozzle guide vane end wall heat transfer
    Harvey, NW
    Rose, MG
    Coupland, J
    Jones, TV
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1999, 121 (02): : 184 - 190
  • [30] Accurate and robust measurement of the external convective heat transfer coefficient based on error analysis
    Ohlsson, K. E. Anders
    Ostin, Ronny
    Olofsson, Thomas
    ENERGY AND BUILDINGS, 2016, 117 : 83 - 90