Influence of cortical bone thickness on miniscrew microcrack formation

被引:19
作者
Nguyen, Melissa V. [1 ]
Codrington, John [2 ]
Fletcher, Lloyd [2 ,3 ]
Dreyer, Craig W. [1 ]
Sampson, Wayne J. [1 ]
机构
[1] Univ Adelaide, Dept Orthodont, Adelaide, SA, Australia
[2] Univ Adelaide, Dept Mech Engn, Adelaide, SA, Australia
[3] Univ Southampton, Dept Mech Engn, Southampton, Hants, England
关键词
ORTHODONTIC MINI-IMPLANTS; RISK-FACTORS; SUCCESS RATE; INSERTION; MICRODAMAGE; STABILITY; RESISTANCE; PLACEMENT; DIAMETER; FAILURE;
D O I
10.1016/j.ajodo.2016.12.028
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this in-vitro study was to investigate the influence of cortical bone thickness on the amount of surface microdamage produced after insertion of orthodontic miniscrews (OM) in porcine tibia bone. Methods: Aarhus OMs (Medicon, Tuttlingen, Germany; diameter, 1.5 mm; length, 6 mm) were inserted into 1.0 mm (group A; n = 10), 1.5 mm (group B; n = 10), and 2.0 mm (group C; n = 10) of porcine cortical bone using a torque-limiting hand screwdriver set at 18 Ncm. A sequential staining technique was used to identify microdamage under laser confocal microscopy. Virtual slices were stitched together using ImageJ software (National Institutes of Health, Bethesda, Md) to form a compressed 2-dimensional composition of the microdamage. The ImageJ software was used to quantify the total damage area, diffuse damage area, maximum crack length, maximum damage radius, and maximum diffuse damage radius. Kruskal-Wallis tests and Wilcoxon rank sum tests were used to analyze the data. Results: All OMs in group A (1.0 mm) were inserted completely; however, 2 OMs from group B (1.5 mm) and all OMs in group C (2.0 mm) failed to insert completely. The entry surface of group C (2.0 mm) exhibited significantly higher amounts of total damage, diffuse damage area, maximum crack length, and maximum crack damage radius compared with groups A (1.0 mm) and B (1.5 mm). The maximum crack length observed on the entry and exit surfaces ranged from 1.03 to 3.06 mm. Conclusions: In this study, we demonstrated a higher level of microdamage after the insertion of OMs into 2.0-mm thick cortical bone compared with 1.0-mm thick cortical bone. Therefore, clinicians need to consider the thickness of the cortical bone at the insertion site, because mechanisms to reduce cortical bone thickness would likely reduce the amount of microdamage formed. A safety zone of 3.5 mm from the OM is also recommended for OMs inserted into 1.0-and 1.5-mm cortical bone thicknesses to minimize any detrimental effects after targeted remodeling.
引用
收藏
页码:301 / 311
页数:11
相关论文
共 43 条
[1]   Success rate of miniscrews relative to their position to adjacent roots [J].
Asscherickx, K. ;
Vannet, B. Vande ;
Wehrbein, H. ;
Sabzevar, M. M. .
EUROPEAN JOURNAL OF ORTHODONTICS, 2008, 30 (04) :330-335
[2]   Success rate and risk factors associated with mini-implants reinstalled in the maxilla [J].
Baek, Seung-Hak ;
Kim, Bo-Mi ;
Kyung, Seung-Hyun ;
Lim, Joong Ki ;
Kim, Young Ho .
ANGLE ORTHODONTIST, 2008, 78 (05) :895-901
[3]   Mini-implant anchorage for the orthodontic practitioner [J].
Baumgaertel, Sebastian ;
Razavi, Mohammad R. ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (04) :621-627
[4]   Predrilling of the implant site: Is it necessary for orthodontic mini-implants? [J].
Baumgaertel, Sebastian .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (06) :825-829
[5]   Buccal cortical bone thickness for mini-implant placement [J].
Baumgaertel, Sebastian ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (02) :230-235
[6]  
Boutrand JP., 2012, BIOCOMPATIBILITY PER
[7]   Damage type and strain mode associations in human compact bone bending fatigue [J].
Boyce, TM ;
Fyhrie, DP ;
Glotkowski, MC ;
Radin, EL ;
Schaffler, MB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (03) :322-329
[8]   VALIDITY OF THE BULK-STAINING TECHNIQUE TO SEPARATE ARTIFACTUAL FROM INVIVO BONE MICRODAMAGE [J].
BURR, DB ;
STAFFORD, T .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (260) :305-308
[9]  
Buschang Peter H, 2008, J Clin Orthod, V42, P513
[10]   The role of osteocytes and bone microstructure in preventing osteoporotic fractures [J].
Hazenberg, Jan G. ;
Taylor, David ;
Lee, T. Clive .
OSTEOPOROSIS INTERNATIONAL, 2007, 18 (01) :1-8