Research of reflectance photometer based on optical absorption

被引:8
|
作者
Huang, Lihua [1 ,2 ]
Zhang, Youbao [1 ]
Xie, Chengke [1 ,2 ]
Qu, Jianfeng [1 ]
Huang, Huijie [1 ,2 ]
Wang, Xiangzhao [1 ,2 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Shanghai 201800, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
来源
OPTIK | 2010年 / 121卷 / 19期
关键词
Nanogold particles; Lateral flow strip; Ideal diffuse reflector; Reflectance photometer; GOLD; PARTICLES;
D O I
10.1016/j.ijleo.2009.04.004
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Gold-labeled lateral flow (LF) assay has been studied extensively due to its sensitiveness, simpleness, and rapidness. In this paper, scattering properties of nanogold particles and LF strip were analyzed. Based on the above analysis, a reflectance photometer has been developed for LF strip labeled by nanogold particles. The integration of reflection optical density was used to indicate the signal of T line and C line. A quantitative equation for cardiac troponin I (cTnI) was deduced to realize quantification of the real cTnI sample, whose correlation of coefficient (R(2)) was 0.989. The variation coefficient (CV) of repetitive experiments was less than 5%. The reflectance photometer was simple, sensitive, stable, and suitable for field detection. (C) 2009 Elsevier GmbH. All rights reserved.
引用
收藏
页码:1725 / 1728
页数:4
相关论文
共 50 条
  • [31] A STABLE OPTICAL PHOTOMETER FOR VACUUM COATING
    BRUCE, PJ
    HODGKINSON, IJ
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1985, 3 (02): : 436 - 437
  • [32] DETERMINATION OF LOW BLOOD-GLUCOSE LEVELS IN NEWBORNS WITH THE REFLECTANCE PHOTOMETER
    DOMINICK, HC
    HUMBEL, R
    BACHMANN, KD
    BANAUCH, D
    CARSTENSEN, CA
    GEBURTSHILFE UND FRAUENHEILKUNDE, 1979, 39 (08) : 642 - 648
  • [33] AN IMMUNOMETRIC DIGOXIN ASSAY FOR USE WITH DRY REAGENT STRIPS AND A REFLECTANCE PHOTOMETER
    SOMMER, RG
    BELCHAK, TL
    BLOCZYNSKI, ML
    BOGUSLAWSKI, SJ
    CLAY, DL
    COREY, PF
    FOLTZ, MM
    FREDRICKSON, RA
    HALMO, BL
    JOHNSON, RD
    MARFURT, KL
    RUNZHEIMER, HV
    MORRIS, DL
    CLINICAL CHEMISTRY, 1988, 34 (06) : 1252 - 1252
  • [34] CORRELATION BETWEEN SERALYZER REFLECTANCE PHOTOMETER THEOPHYLLINE ASSAY AND AN EMIT ASSAY
    SINGH, P
    LIM, DT
    ENRIGHT, T
    DELACRUZ, RY
    NOUTSIS, S
    LIM, AT
    MARIANO, R
    CHAKRIN, AL
    ANNALS OF ALLERGY, 1987, 59 (03): : 176 - 178
  • [36] Accuracy of black carbon measurements by a filter-based absorption photometer with a heated inlet
    Ohata, Sho
    Kondo, Yutaka
    Moteki, Nobuhiro
    Mori, Tatsuhiro
    Yoshida, Atsushi
    Sinha, Puna R.
    Koike, Makoto
    AEROSOL SCIENCE AND TECHNOLOGY, 2019, 53 (09) : 1079 - 1091
  • [37] The optical pyrometer as a brightness photometer.
    Forsythe, WE
    JOURNAL OF THE FRANKLIN INSTITUTE, 1924, 197 : 517 - 525
  • [38] USE OF A MICRO REFLECTANCE PHOTOMETER TO MEASURE COLOR UNIFORMITY AND GLOSS OF TABLETS
    MATTHEWS, BA
    MATSUMOTO, S
    SHIBATA, M
    DRUG DEVELOPMENT COMMUNICATIONS, 1975, 1 (04): : 303 - 329
  • [39] Joint remote sensing of aerosol optical properties and surface reflectance by sun-photometer and satellite In the urban area of Beijing, China
    Mao, JT
    Zhang, JH
    OPTICAL REMOTE SENSING OF THE ATMOSPHERE AND CLOUDS III, 2003, 4891 : 258 - 264
  • [40] ANALYSIS OF SERUM URIC-ACID WITH AMES SERALYZER REFLECTANCE PHOTOMETER
    LENT, R
    KARMEN, A
    CHANG, ES
    CLINICAL CHEMISTRY, 1980, 26 (07) : 1010 - 1010