Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 2: plain radiography and diagnostic fluoroscopy

被引:7
作者
Celier, David [1 ]
Roch, Patrice [1 ]
Etard, Cecile [1 ]
Ducou Le Pointe, Hubert [2 ,3 ,4 ]
Brisse, Herve J. [4 ,5 ,6 ]
机构
[1] Inst Radioprotect & Surete Nucl, 31 Ave Div Leclerc, Fontenay Aux Roses, France
[2] Hop Enfants Armand Trousseau, AP HP, Dept Pediat Imaging, 26 Ave Docteur Arnold Netter, Paris, France
[3] Univ Paris 06, Sorbonne Univ, Paris, France
[4] French Speaking Soc Pediat & Prenatal Imaging SFI, Paris, France
[5] Inst Curie, Imaging Dept, 26 Rue Ulm, Paris, France
[6] Paris Sci & Lettres Res Univ, Paris, France
关键词
Radiography; Fluoroscopy; Paediatrics; Radiation exposure; Radiation protection; EXPOSURE; SYSTEM; RISK;
D O I
10.1007/s00330-019-06406-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To report on a dose survey conducted by the French societies of radiology and paediatric imaging (SFR and SFIPP) and the French public service expert in nuclear and radiological risks (IRSN), and to suggest new diagnostic reference levels (DRLs) for paediatric plain radiography and diagnostic fluoroscopy. Methods Dose reports concerning four radiography procedures and three diagnostic fluoroscopy procedures performed in 2015-2016 on children aged 0-15 years were collected from 16 imaging departments on a voluntary basis. Air kerma-area product (P-KA) was recorded for at least 10 patients per procedure, per centre and per age group. New DRLs were calculated as the 3rd quartiles of the distributions of the median values. Results Results from 2249 radiography examinations and 1235 diagnostic fluoroscopy procedures were obtained. A noticeable variability in patient exposure between facilities was observed in diagnostic fluoroscopy and to a lesser extent in plain radiography. DRLs are proposed for each procedure and each age group. Conclusions This study showed that the applicable national DRLs in plain radiography were obsolete and its results have been recently used by the French authorities to update them. In diagnostic fluoroscopy, large differences of doses were observed, even among departments accustomed to paediatric procedures. The new national DRLs will be useful for optimising diagnostic practice.
引用
收藏
页码:1182 / 1190
页数:9
相关论文
共 36 条
[1]  
[Anonymous], ECR 2017 EUROSAFE IM
[2]  
[Anonymous], ANAL DONNEES RELATIV
[3]  
[Anonymous], ANAL DONNEES RELATIV
[4]  
[Anonymous], J OFFICIEL REPUBLIQU
[5]  
[Anonymous], 2016, Journal Officiel de la Republique Francaise
[6]  
[Anonymous], ANAL DONNEES RELATIV
[7]  
[Anonymous], 2014, RAD PROT SAF RAD SOU
[8]  
[Anonymous], 10 HERCA M 31 OCT 20
[9]  
[Anonymous], ANAL DONNEES RELATIV
[10]  
[Anonymous], MED RAD EXP EUR PO 1