Vision-specific quality of life and modes of refractive error correction

被引:36
作者
Walline, JJ [1 ]
Bailey, MD [1 ]
Zadnik, K [1 ]
机构
[1] Ohio State Univ, Coll Optometry, Columbus, OH 43210 USA
关键词
quality of life; refractive error correction; NEI-VFQ; contact lenses; spectacles;
D O I
10.1097/00006324-200012000-00011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Many studies currently use surveys to assess patients' reports of vision-specific quality of life to determine the impact of the disease or the most appropriate mode of treatment. One such instrument, the National Eye Institute Visual Function Questionnaire (NEI-VFQ), was developed to assess vision-related quality of life with respect to emotional well-being and social function as well as difficulty with tasks and symptoms. We administered the NEI-VFQ to 218 subjects free of eye disease to see if the survey was sensitive enough to detect differences in three modes of refractive error correction: spectacles, soft contact lenses, and rigid contact lenses. Methods: Surveys were administered, to 117 rigid contact lens wearers, 51 spectacle wearers, and 50 soft contact lens wearers. Kruskal-Wallis one-way analysis of variance was conducted to determine significant differences in each of the subscales. Results: The Peripheral Vision subscale score (mean a SD) was 92.6 +/- 15.2 for the spectacle wearers, 100.0 +/- 0.0 for the soft contact lens wearers, and 98.3 +/- 7.1 for the rigid gas-permeable contact lens wearers; the spectacle wearers' Peripheral Vision score was significantly lower than the other two groups (Wilcoxon rank sum, p < 0.003 for both). The spectacle weavers (96.6 +/- 9.2) also had a significantly lower Dependency subscale score than the rigid contact lens group (99.7 +/- 1.5) (Wilcoxon rank sum, p = 0.001). There were no significant differences between the three groups detected in the mean of any of the other subscale scores. At least 50% of the subjects reported the maximum score for 6 of the 11 subscales. Given our sample size, we have 100% power to detect a difference of 10 points with a SD of 10 at the <alpha> = 0.05 level. Conclusion: The NEI-VFQ is not appropriate for detecting significant differences in vision-related quality of life among spectacle, soft contact lens, and rigid gas-permeable contact lens wearers, primarily due to maximum ratings by many of the subjects. (Optom Vis Sci 2000;77:648-652).
引用
收藏
页码:648 / 652
页数:5
相关论文
共 28 条
[21]  
PATRICK SL, 1989, MED CARE S3, V27, pS217
[22]   Laser in situ keratomileus using the LaserSight 200 laser:: Results of 950 consecutive cases [J].
Reviglio, VE ;
Luna, JD ;
Rodríguez, ML ;
García, FE ;
Juárez, CP .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (08) :1062-1068
[23]   Videokeratographic changes after laser in situ keratomileusis to correct high myopia [J].
Spadea, L ;
Bianco, G ;
Masini, MC ;
Balestrazzi, E .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (12) :1589-1595
[24]  
Steel SE, 1996, OPHTHAL PHYSL OPT, V16, P95, DOI 10.1016/0275-5408(95)00026-7
[25]   THE VF-14 - AN INDEX OF FUNCTIONAL IMPAIRMENT IN PATIENTS WITH CATARACT [J].
STEINBERG, EP ;
TIELSCH, JM ;
SCHEIN, OD ;
JAVITT, JC ;
SHARKEY, P ;
CASSARD, SD ;
LEGRO, MW ;
DIENERWEST, M ;
BASS, EB ;
DAMIANO, AM ;
STEINWACHS, DM ;
SOMMER, A .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (05) :630-638
[26]  
STEINBERG EP, 1994, OPHTHALMOLOGY, V101, P1131
[27]   THE MOS SHORT-FORM GENERAL HEALTH SURVEY - RELIABILITY AND VALIDITY IN A PATIENT POPULATION [J].
STEWART, AL ;
HAYS, RD ;
WARE, JE .
MEDICAL CARE, 1988, 26 (07) :724-732
[28]  
Zadnik K, 1998, INVEST OPHTH VIS SCI, V39, P2537