Comparing predictions by existing explicit emission models to real world observations of formaldehyde emissions from solid materials

被引:11
作者
Johnston, Christopher Just [1 ,2 ]
Nielsen, Toke Rammer [2 ]
Toftum, Jorn [2 ]
机构
[1] NIRAS Grp, Sortemosevej 19, DK-3450 Lillerod, Denmark
[2] Tech Univ Denmark, Dept Civil Engn, Brovej 118, DK-2800 Lyngby, Denmark
关键词
volatile organic compound; formaldehyde; emissions; mass transfer; small test chambers; building material; SEMIVOLATILE ORGANIC-COMPOUNDS; INITIAL EMITTABLE CONCENTRATION; C-HISTORY METHOD; DRY BUILDING-MATERIALS; MASS-TRANSFER MODEL; VOC EMISSIONS; CHARACTERISTIC PARAMETERS; TEMPERATURE; VENTILATION; VOLATILE;
D O I
10.1007/s12273-019-0567-8
中图分类号
O414.1 [热力学];
学科分类号
摘要
Existing general explicit mass transfer models for volatile organic compound emissions have been validated against experimental results from small test chambers. This study compared emission rates predicted by such models to observations from homes, large test chambers and full scale experiments. The comparison revealed that the examined explicit emission models could not simulate behaviour observed under real world conditions for the cases studied. It is hypothesised that the reasons for the observed discrepancies include that: (1) There is a shortage of detailed information on the actual physical conditions at the emitting surfaces under real world conditions. (2) The mathematics behind the explicit emission models does not allow such models to fully capture the dynamic behaviour of a system with varying temperature and relative humidity. (3) The assumption that change in the concentration in an emitting material is determined by diffusion alone, implicitly implying that generation is negligible, may not be valid outside small test chambers.
引用
收藏
页码:185 / 195
页数:11
相关论文
共 41 条
[1]   INDOOR AIR-POLLUTION DUE TO CHIPBOARD USED AS A CONSTRUCTION MATERIAL [J].
ANDERSEN, I ;
LUNDQVIST, GR ;
MOLHAVE, L .
ATMOSPHERIC ENVIRONMENT, 1975, 9 (12) :1121-1127
[2]  
Bartzis J.G., 2013, OFFICAIR FIN WORKSH
[3]   An analytical model for VOCs emission from dry building materials [J].
Deng, BQ ;
Kim, CN .
ATMOSPHERIC ENVIRONMENT, 2004, 38 (08) :1173-1180
[4]   A Framework for Modelling Non-Steady-State Concentrations of Semivolatile Organic Compounds Indoors - I: Emissions from Diffusional Sources and Sorption by Interior Surfaces [J].
Guo, Zhishi .
INDOOR AND BUILT ENVIRONMENT, 2013, 22 (04) :685-700
[5]   Smart ventilation energy and indoor air quality performance in residential buildings: A review [J].
Guyot, Gaelle ;
Sherman, Max H. ;
Walker, Iain S. .
ENERGY AND BUILDINGS, 2018, 165 :416-430
[6]  
Haghighat F, 2005, ASHRAE TRAN, V111, P635
[7]  
HOETJER JJ, 1986, ACS SYM SER, V316, P125
[8]   An analytical mass transfer model for predicting VOC emissions from multi-layered building materials with convective surfaces on both sides [J].
Hu, H. P. ;
Zhang, Y. P. ;
Wang, X. K. ;
Little, J. C. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (11-12) :2069-2077
[9]   Modelling of volatile organic compounds emission from dry building materials [J].
Huang, H ;
Haghighat, F .
BUILDING AND ENVIRONMENT, 2002, 37 (12) :1349-1360
[10]   Influence of humidity on the initial emittable concentration of formaldehyde and hexaldehyde in building materials: experimental observation and correlation [J].
Huang, Shaodan ;
Xiong, Jianyin ;
Cai, Chaorui ;
Xu, Wei ;
Zhang, Yinping .
SCIENTIFIC REPORTS, 2016, 6