Choice of valve type and poor ventricular catheter placement: Modifiable factors associated with ventriculoperitoneal shunt failure

被引:18
|
作者
Jeremiah, Kealeboga Josephine [1 ]
Cherry, Catherine Louise [2 ,3 ,5 ]
Wan, Kai Rui [1 ]
Toy, Jennifer Ah [1 ]
Wolfe, Rory [1 ]
Danks, Robert Andrew [1 ,4 ]
机构
[1] Monash Med Ctr, Neurosurg Dept, 246 Clayton Rd, Clayton, Vic 3168, Australia
[2] Monash Univ, Dept Infect Dis, Commercial Rd, Melbourne, Vic 3004, Australia
[3] Alfred Hosp, Burnet Inst, Ctr Biomed Res, Commercial Rd, Melbourne, Vic, Australia
[4] Monash Univ, Monash Med Ctr, Dept Surg, Clayton, Vic 3800, Australia
[5] Univ Witwatersrand, Sch Physiol, Johannesburg, South Africa
关键词
Hydrocephalus; Shunt; Ventricles; PEDIATRIC-PATIENTS; COMPLICATIONS; HYDROCEPHALUS; OBSTRUCTION; CHILDREN;
D O I
10.1016/j.jocn.2015.07.026
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Ventriculoperitoneal (VP) shunt insertion is a common neurosurgical procedure, essentially unchanged in recent years, with high revision rates. We aimed to identify potentially modifiable associations with shunt failure. One hundred and forty patients who underwent insertion of a VP shunt from 2005-2009 were followed for 5-9 years. Age at shunt insertion ranged from 0 to 91 years (median 44, 26% <18 years). The main causes of hydrocephalus were congenital (26%), tumour-related (25%), post-haemorrhagic (24%) or normal pressure hydrocephalus (19%). Fifty-eight (42%) patients required >= 1 shunt revision. Of these, 50 (88%) were for proximal catheter blockage. The median time to first revision was 108 days. Early post-operative CT scans were available in 105 patients. Using a formal grading system, catheter placement was considered excellent in 49 (47%) but poor (extraventricular) in 13 (12%). On univariate analysis, younger age, poor ventricular catheter placement and use of a non-programmable valve were associated with shunt failure. On logistic regression modelling, the independent associations with VP shunt failure were poor catheter placement (odds ratio [OR] 4.9, 95% confidence interval [CI] 1.3-18.9, p = 0.02) and use of a non-programmable valve (OR 0.4, 95% CI 0.2-1.0, p = 0.04). In conclusion, poor catheter placement (revision rate 77%) was found to be the strongest predictor of shunt failure, with no difference in revisions between excellent (43%) and moderate (43%) catheter placement. Avoiding poor placement in those with mild or moderate ventriculomegaly may best reduce VP shunt failures. There may also be an influence of valve choice on VP shunt survival. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:95 / 98
页数:4
相关论文
共 13 条
  • [1] Risk factors associated with distal catheter migration following ventriculoperitoneal shunt placement
    Abode-Iyamah, Kingsley O.
    Khanna, Ryan
    Rasmussen, Zachary D.
    Flouty, Oliver
    Dandaleh, Nader S.
    Greenlee, Jeremy
    Howard, Matthew A., III
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 25 : 46 - 49
  • [2] Prediction of ventriculoperitoneal shunt placement based on type of failure during external ventricular drain wean
    Lewis, Ariane
    Kimberly, W. Taylor
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2014, 125 : 109 - 113
  • [3] Indications for Pediatric External Ventricular Drain Placement and Risk Factors for Conversion to a Ventriculoperitoneal Shunt
    Walker, Corey T.
    Stone, Jonathan J.
    Jacobson, Max
    Phillips, Valerie
    Silberstein, Howard J.
    PEDIATRIC NEUROSURGERY, 2012, 48 (06) : 342 - 347
  • [4] Factors associated with 30-day ventriculoperitoneal shunt failure in pediatric and adult patients
    Anderson, Ian A.
    Saukila, Louise F.
    Robins, James M. W.
    Akhunbay-Fudge, Christopher Y.
    Goodden, John R.
    Tyagi, Atul K.
    Phillips, Nick
    Chumas, Paul D.
    JOURNAL OF NEUROSURGERY, 2019, 130 (01) : 145 - 153
  • [5] Proximal ventricular shunt malfunctions in children: Factors associated with failure
    Buster, Bryan E.
    Bonney, Phillip A.
    Cheema, Ahmed A.
    Glenn, Chad A.
    Conner, Andrew K.
    Safavi-Abbasi, Sam
    Andrews, Mason B.
    Gross, Naina L.
    Mapstone, Timothy B.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 24 : 94 - 98
  • [6] Spontaneous Cerebellar Hemorrhage with the Fourth Ventricular Hemorrhage: Risk Factors Associated with Ventriculoperitoneal Shunt
    Shin, Donguk
    Woo, Hyun-Jin
    Park, Jaechan
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2012, 52 (04) : 320 - 324
  • [7] The effect of image-guided ventricular catheter placement on shunt failure: a systematic review and meta-analysis
    Spennato, Pietro
    Vitulli, Francesca
    Onorini, Nicola
    Imperato, Alessia
    Mirone, Giuseppe
    Ruggiero, Claudio
    Cinalli, Giuseppe
    CHILDS NERVOUS SYSTEM, 2022, 38 (06) : 1069 - 1076
  • [8] The effect of image-guided ventricular catheter placement on shunt failure: a systematic review and meta-analysis
    Pietro Spennato
    Francesca Vitulli
    Nicola Onorini
    Alessia Imperato
    Giuseppe Mirone
    Claudio Ruggiero
    Giuseppe Cinalli
    Child's Nervous System, 2022, 38 : 1069 - 1076
  • [9] Factors associated with ventricular catheter movement and inaccurate catheter location: post hoc analysis of the Hydrocephalus Clinical Research Network Ultrasound-Guided Shunt Placement study
    Whitehead, William E.
    Riva-Cambrin, Jay
    Wellons, John C., III
    Kulkarni, Abhaya V.
    Browd, Samuel
    Limbrick, David
    Rozzelle, Curtis
    Tamber, Mandeep S.
    Simon, Tamara D.
    Shannon, Chevis N.
    Holubkov, Richard
    Oakes, W. Jerry
    Luerssen, Thomas G.
    Walker, Marion L.
    Drake, James M.
    Kestle, John R. W.
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2014, 14 (02) : 173 - 178
  • [10] Comparison of the accuracy and proximal shunt failure rate of freehand placement versus intraoperative guidance in parietooccipital ventricular catheter placement
    Wilson, Thomas J.
    McCoy, Kathleen E.
    Al-Holou, Wajd N.
    Molina, Sergio L.
    Smyth, Matthew D.
    Sullivan, Stephen E.
    NEUROSURGICAL FOCUS, 2016, 41 (03)