Image-Based Background Phase Error Correction in 4D Flow MRI Revisited

被引:39
作者
Busch, Julia [1 ,2 ]
Giese, Daniel [3 ]
Kozerke, Sebastian [1 ,2 ,4 ]
机构
[1] Univ Zurich, Inst Biomed Engn, Gloriastr 35, CH-8092 Zurich, Switzerland
[2] ETH, Gloriastr 35, CH-8092 Zurich, Switzerland
[3] Univ Hosp Cologne, Dept Radiol, Cologne, Germany
[4] Kings Coll London, Div Imaging Sci & Biomed Engn, London, England
基金
瑞士国家科学基金会;
关键词
APPARENT DIFFUSION-COEFFICIENT; PROSTATE-CANCER; WEIGHTED MRI; 3; T; METAANALYSIS; RESOLUTION; QUALITY; VALUES; LIVER; DWI;
D O I
10.1002/jmri.25668
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To correct background phase errors in phase-contrast magnetic resonance imaging ( MRI), image-based correction by referencing through stationary tissue is widely used. The aim of the present study was a detailed assessment of background phase errors in 4D Flow MRI and limitations of image-based correction. Materials and Methods: In a phantom study, 4D Flow MRI data were acquired for typical settings on two clinical 3T MR systems. Background errors were analyzed with respect to their spatial order and minimum requirements regarding the signal-to-noise ratio ( SNR) and the amount of stationary tissue for image-based correction were assessed. For in vivo evaluation, data of the aorta were acquired on one 3T MR system in five healthy subjects including subsequent scans on the stationary phantom as reference. Results: Background errors were found to exhibit spatial variation of first-to third-order. For correction, a minimum SNR of 20 was needed to achieve an error of less than 0.4% of the encoding velocity. The minimum amount of stationary tissue was strongly dependent on the spatial order requiring at least 25%, 60%, and 75% of stationary tissue for first-, second-, and third-order correction. In vivo evaluation showed that with 35-41% of stationary tissue available only first-order correction yielded a significant reduction ( P < 0.01). Conclusion: Background phase errors can range from first to third spatial order in 4D Flow MRI requiring correction with appropriate polynomials. At the same time, the limited amount of stationary tissue available in vivo limits imagebased background phase correction to first spatial order. Level of Evidence: 1 Technical Efficacy: Stage 1
引用
收藏
页码:1516 / 1525
页数:10
相关论文
共 35 条
[1]   Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations [J].
不详 .
NEOPLASIA, 2009, 11 (02) :102-125
[2]   Multiband accelerated spin-echo echo planar imaging with reduced peak RF power using time-shifted RF pulses [J].
Auerbach, Edward J. ;
Xu, Junqian ;
Yacoub, Essa ;
Moeller, Steen ;
Ugurbil, Kamil .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (05) :1261-1267
[3]   Diffusion-Weighted Imaging of the Prostate Image Quality and Geometric Distortion of Readout-Segmented Versus Selective-Excitation Accelerated Acquisitions [J].
Barth, Borna K. ;
Cornelius, Alexander ;
Nanz, Daniel ;
Eberli, Daniel ;
Donati, Olivio F. .
INVESTIGATIVE RADIOLOGY, 2015, 50 (11) :785-791
[4]   A literature review of the association between diffusion-weighted MRI derived apparent diffusion coefficient and tumour aggressiveness in pelvic cancer [J].
Bollineni, V. R. ;
Kramer, G. ;
Liu, Y. ;
Melidis, C. ;
deSouzac, N. M. .
CANCER TREATMENT REVIEWS, 2015, 41 (06) :496-502
[5]   Apparent Diffusion Coefficient Value and Ratio as Noninvasive Potential Biomarkers to Predict Prostate Cancer Grading: Comparison With Prostate Biopsy and Radical Prostatectomy Specimen [J].
De Cobelli, Francesco ;
Ravelli, Silvia ;
Esposito, Antonio ;
Giganti, Francesco ;
Gallina, Andrea ;
Montorsi, Francesco ;
Del Maschio, Alessandro .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) :550-557
[6]   Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters [J].
Dietrich, Olaf ;
Raya, Jose G. ;
Reeder, Scott B. ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) :375-385
[7]   A Low Power Radiofrequency Pulse for Simultaneous Multislice Excitation and Refocusing [J].
Eichner, Cornelius ;
Wald, Lawrence L. ;
Setsompop, Kawin .
MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) :949-958
[8]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139
[9]   INNER VOLUME MR IMAGING - TECHNICAL CONCEPTS AND THEIR APPLICATION [J].
FEINBERG, DA ;
HOENNINGER, JC ;
CROOKS, LE ;
KAUFMAN, L ;
WATTS, JC ;
ARAKAWA, M .
RADIOLOGY, 1985, 156 (03) :743-747
[10]   Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging [J].
Feinberg, David A. ;
Moeller, Steen ;
Smith, Stephen M. ;
Auerbach, Edward ;
Ramanna, Sudhir ;
Glasser, Matt F. ;
Miller, Karla L. ;
Ugurbil, Kamil ;
Yacoub, Essa .
PLOS ONE, 2010, 5 (12)