A Single Channel Concurrent Data Transmission System for Detection of 4-Electrode Dissolved Oxygen and Temperature

被引:0
作者
Nag, Amlan [1 ]
Narayan, Tarun [2 ]
O'Riordan, Alan [2 ]
Lovera, Pierre [2 ]
Mitra, Srinjoy [1 ]
机构
[1] Univ Edinburgh, Edinburgh, Midlothian, Scotland
[2] Tyndall Natl Inst, Cork, Ireland
来源
2022 20TH IEEE INTERREGIONAL NEWCAS CONFERENCE (NEWCAS) | 2022年
基金
欧盟地平线“2020”;
关键词
4 Electrode DO; On-chip temperature sensor; Dual sensing; PTAT oscillator; Triple data transmission; water quality; SENSORS;
D O I
10.1109/NEWCAS52662.2022.9842084
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We propose a time domain analog front-end for real time water quality monitoring which can simultaneously detect dissolved oxygen (DO) concentration and temperature and transmit on a single ISM frequency band. The DO information changes the centre frequency of an oscillator and a delay line switches the oscillator ON/OFF, where it's ON/OFF time depends on the ambient temperature. A power amplifier (PA) sends that signal to an antenna which can choose among three different power supplies to have variable output swings depending on the present operating voltametric range. Therefore, the PA output essentially combines and transmits three data simultaneously over a single channel of the 2.4GHz ISM band. The linear ranges of amperometric and temperature measurement circuits are +/- 200nA and 2 degrees C-60 degrees C (with 4 different sensitivities) having average R-2 linearity of 0.99993 and 0.9997. Their respective noise levels are 40.4 pA and 0.33 ppm/ degrees C
引用
收藏
页码:60 / 64
页数:5
相关论文
共 32 条
  • [1] Electrochemical time-of-flight responses at double-band generator-collector devices under pulsed conditions
    Amatore, Christian
    Sella, Catherine
    Thouin, Laurent
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 593 (1-2): : 194 - 202
  • [2] [Anonymous], ISSCC
  • [3] Generator-collector double electrode systems: A review
    Barnes, Edward O.
    Lewis, Grace E. M.
    Dale, Sara E. C.
    Marken, Frank
    Compton, Richard G.
    [J]. ANALYST, 2012, 137 (05) : 1068 - 1081
  • [4] Battistuzzi G, 2001, EUR J INORG CHEM, P2989
  • [5] Microelectrode generator-collector systems for electrolytic titration: theoretical and practical considerations
    Bell, Christopher G.
    Seelanan, Parinya
    O'Hare, Danny
    [J]. ANALYST, 2017, 142 (21) : 4048 - 4057
  • [6] A comparison between potentiostatic circuits with grounded work or auxiliary electrode
    Busoni, L
    Carlà, M
    Lanzi, L
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (04) : 1921 - 1923
  • [7] A Portable Analog Lock-In Amplifier for Accurate Phase Measurement and Application in High-Precision Optical Oxygen Concentration Detection
    Chen, Xi
    Chang, Jun
    Wang, Fupeng
    Wang, Zongliang
    Wei, Wei
    Liu, Yuanyuan
    Qin, Zengguang
    [J]. PHOTONIC SENSORS, 2017, 7 (01) : 27 - 36
  • [8] A Microwatt Dual-Mode Electrochemical Sensing Current Readout With Current-Reducer Ramp Waveform Generation
    Chen, Yi-Chia
    Lu, Shao-Yung
    Liao, Yu-Te
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2019, 13 (06) : 1163 - 1174
  • [9] CMOS-based phase fluorometric oxygen sensor system
    Chodavarapu, Vamsy P.
    Shubin, Daniil O.
    Bukowski, Rachel M.
    Titus, Albert H.
    Cartwright, Alexander N.
    Bright, Frank V.
    [J]. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2007, 54 (01) : 111 - 118
  • [10] Design of Smart Sensors for Real-Time Water Quality Monitoring
    Cloete, Niel Andre
    Malekian, Reza
    Nair, Lakshmi
    [J]. IEEE ACCESS, 2016, 4 : 3975 - 3990