Video Quality Assessment Using Spatio-Velocity Contrast Sensitivity Function

被引:4
|
作者
Hirai, Keita [1 ]
Tumurtogoo, Jambal [1 ]
Kikuchi, Ayano [1 ]
Tsumura, Norimichi [1 ]
Nakaguchi, Toshiya [1 ]
Miyake, Yoichi [2 ]
机构
[1] Chiba Univ, Grad Sch Adv Integrat Sci, Chiba 2638522, Japan
[2] Chiba Univ, Res Ctr Frontier Med Engn, Chiba 2638522, Japan
来源
IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS | 2010年 / E93D卷 / 05期
关键词
objective video quality assessment; spatio-velocity contrast sensitivity function; image diffrence; subjective evaluation; rank order correlation coefficient; MOTION;
D O I
10.1587/transinf.E93.D.1253
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Due to the development and popularization of high-definition televisions, digital video cameras, Blu-ray discs, digital broadcasting, IP television and so on, it plays an important role to identify and quantify video quality degradations. In this paper, we propose SV-CIELAB which is an objective video quality assessment (VQA) method using a spatio-velocity contrast sensitivity function (SV-CSF). In SV-CIELAB, motion information in videos is effectively utilized for filtering unnecessary information in the spatial frequency domain. As the filter to apply videos, we used the SV-CSF. It is a modulation transfer function of the human visual system, and consists of the relationship among contrast sensitivities, spatial frequencies and velocities of perceived stimuli. In the filtering process, the SV-CSF cannot be directly applied in the spatial frequency domain because spatial coordinate information is required when using velocity information. For filtering by the SV-CSF, we obtain video frames separated in spatial frequency domain. By using velocity information, the separated frames with limited spatial frequencies are weighted by contrast sensitivities in the SV-CSF model. In SV-CIELAB, the criteria are obtained by calculating image differences between filtered original and distorted videos. For the validation of SV-CIELAB, subjective evaluation experiments were conducted. The subjective experimental results were compared with SV-CIELAB and the conventional VQA methods such as CIELAB color difference, Spatial-CIELAB, signal to noise ratio and so on. From the experimental results, it was shown that SV-CIELAB is a more efficient VQA method than the conventional methods.
引用
收藏
页码:1253 / 1262
页数:10
相关论文
共 50 条
  • [41] Performance improvement in SHVC using contrast sensitivity function
    Simon, Sini M.
    Sreelekha, G.
    PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 807 - 811
  • [42] Performance Improvement in HEVC Using Contrast Sensitivity Function
    Simon, Sini M.
    Antony, Abhilash
    Sreelekha, G.
    2016 INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING, COMMUNICATIONS AND INFORMATICS (ICACCI), 2016, : 2237 - 2241
  • [43] No-reference video quality assessment method based on spatio-temporal features using the ELM algorithm
    da Silva, Wyllian Bezerra
    Mikowski, Alexandre
    Casali, Rafael Machado
    IET IMAGE PROCESSING, 2020, 14 (07) : 1316 - 1326
  • [44] Contrast sensitivity assessment using the visual performance tester
    Argento, C
    Cosentino, MJ
    Rodriguez, E
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (06): : 806 - 809
  • [45] Using multiple spatio-temporal features to estimate video quality
    Freitas, Pedro Garcia
    Akamine, Welington Y. L.
    Farias, Mylene C. Q.
    SIGNAL PROCESSING-IMAGE COMMUNICATION, 2018, 64 : 1 - 10
  • [46] Model of luminance contrast-sensitivity function for application to image assessment
    Westland, Stephen
    Owens, Huw
    Cheung, Vien
    Paterson-Stephens, Iain
    COLOR RESEARCH AND APPLICATION, 2006, 31 (04): : 315 - 319
  • [47] Automated assessment of the visual contrast-sensitivity function in the hooded rat
    Keller, J.
    Strasburger, H.
    Cerutti, D. T.
    Sabel, B. A.
    PERCEPTION, 1998, 27 : 72 - 73
  • [48] Contrast sensitivity function in children: Normalized notation for the assessment and diagnosis of diseases
    Montés-Micó R.
    Ferrer-Blasco T.
    Documenta Ophthalmologica, 2001, 103 (3) : 175 - 186
  • [49] Subjective contrast sensitivity function assessment in stereoscopic viewing of Gabor patches
    Rousson, Johanna
    Haar, Jeremy
    Platisa, Ljiljana
    Piepers, Bastian
    Kimpe, Tom
    Philips, Wilfried
    STEREOSCOPIC DISPLAYS AND APPLICATIONS XXVI, 2015, 9391
  • [50] CLINICAL-ASSESSMENT OF BINOCULAR VISUAL FUNCTION USING THE PELLI-ROBSON CONTRAST SENSITIVITY CHART
    PARDHAN, S
    ELLIOTT, DB
    GILCHRIST, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 1281 - 1281