Primary stentriever versus combined stentriever plus aspiration thrombectomy approaches: in vitro stroke model comparison

被引:62
作者
Mokin, Maxim [1 ]
Ionita, Ciprian N. [1 ,2 ,3 ]
Nagesh, Swetadri Vasan Setlur [2 ,3 ,4 ,5 ]
Rudin, Stephen [1 ,2 ,3 ,5 ,6 ]
Levy, Elad I. [1 ,3 ]
Siddiqui, Adnan H. [1 ,3 ]
机构
[1] SUNY Buffalo, Dept Neurosurg, Buffalo, NY 14203 USA
[2] SUNY Buffalo, Dept Biomed Engn, Buffalo, NY 14260 USA
[3] SUNY Buffalo, Toshiba Stroke & Vasc Res Ctr, Buffalo, NY 14260 USA
[4] SUNY Buffalo, Dept Elect Engn, Buffalo, NY 14260 USA
[5] SUNY Buffalo, Dept Mech & Aerosp Engn, Buffalo, NY 14260 USA
[6] SUNY Buffalo, Dept Phys & Biophys, Buffalo, NY 14260 USA
基金
美国国家卫生研究院;
关键词
Stroke; Thrombectomy; Technique; ACUTE ISCHEMIC-STROKE; MECHANICAL THROMBECTOMY; MICROANGIOGRAPHIC FLUOROSCOPE; SILICONE MODELS; REVASCULARIZATION; EXPERIENCE; OUTCOMES; SAFETY; SYSTEM;
D O I
10.1136/neurintsurg-2014-011148
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background Artificial stroke models can be used for testing various thrombectomy devices. Objective To determine the value of combined stentriever-aspiration thrombectomy compared with the stentriever-alone approach. Methods We designed an in vitro model of the intracranial circulation with a focus on the middle cerebral artery (MCA) that closely resembles the human intracranial circulation. After introducing fresh clot in the MCA, we used conventional biplane angiography and microangiographic fluoroscopy to compare recanalization rates and occurrence of emboli in new, unaffected territory for thrombectomy approaches in which a stentriever (Solitaire flow restoration stentriever, Covidien) was used alone or in combination with continuous manual aspiration through a Navien catheter (Covidien). Results In a total of 22 experiments (11 for each approach), successful clot delivery to the MCA was achieved in all cases. Successful angiographic recanalization (thrombolysis in cerebral infarction score of 2b-3) was achieved more frequently with the combined stentriever-aspiration approach than with the stentriever-alone approach (in 10 vs 4 experiments, p=0.023). Emboli in new territory occurred in three experiments with the stentriever-alone approach, and none were seen with the combined approach (p=0.21). Conclusions The combined stentriever-aspiration approach to thrombectomy leads to better angiographic recanalization rates than use of the stentriever alone. Further experiments are needed to test the value of balloon-guide catheters and aspiration performed using other types of catheters and modes of aspiration.
引用
收藏
页码:453 / 457
页数:5
相关论文
共 23 条
  • [1] Use of the Microangiographic Fluoroscope for Coiling of Intracranial Aneurysms
    Binning, Mandy J.
    Orion, David
    Yashar, Parham
    Webb, Sharon
    Ionita, Ciprian N.
    Jain, Amit
    Rudin, Stephen
    Hopkins, L. Nelson
    Siddiqui, Adnan H.
    Levy, Elad I.
    [J]. NEUROSURGERY, 2011, 69 (05) : 1131 - 1138
  • [2] Effectiveness of Mechanical Endovascular Thrombectomy in a Model System of Cerebrovascular Occlusion
    Chueh, J. Y.
    Wakhloo, A. K.
    Gounis, M. J.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (10) : 1998 - 2003
  • [3] Reduction in Distal Emboli With Proximal Flow Control During Mechanical Thrombectomy A Quantitative In Vitro Study
    Chueh, Ju-Yu
    Kuehn, Anna Luisa
    Puri, Ajit S.
    Wilson, Scott D.
    Wakhloo, Ajay K.
    Gounis, Matthew J.
    [J]. STROKE, 2013, 44 (05) : 1396 - +
  • [4] Mechanical Properties of Human Coronary Arteries
    Claes, E.
    Atienza, J. M.
    Guinea, G. V.
    Rojo, F. J.
    Bernal, J. M.
    Revuelta, J. M.
    Elices, M.
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3792 - 3795
  • [5] Dumont TM, 2013, J NEUROINTERV SURG, V6, pe26
  • [6] A thromboembolic model for the efficacy and safety evaluation of combined mechanical and pharmacologic revascularization strategies
    Gounis, Matthew J.
    Nogueira, Raul G.
    Mehra, Manik
    Chueh, Juyu
    Wakhloo, Ajay K.
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 : 85 - 89
  • [7] Gralla J, 2006, AM J NEURORADIOL, V27, P1357
  • [8] Distal aspiration with retrievable stent assisted thrombectomy for the treatment of acute ischemic stroke
    Humphries, William
    Hoit, Daniel
    Doss, Vinodh T.
    Elijovich, Lucas
    Frei, Donald
    Loy, David
    Dooley, Gwen
    Turk, Aquilla S.
    Chaudry, Imran
    Turner, Raymond
    Mocco, J.
    Morone, Peter
    Fiorella, David
    Siddiqui, Adnan
    Mokin, Maxim
    Arthur, Adam S.
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (02) : 90 - 94
  • [9] A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager
    Jain, Amit
    Bednarek, D. R.
    Ionita, Ciprian
    Rudin, S.
    [J]. MEDICAL PHYSICS, 2011, 38 (07) : 4112 - 4126
  • [10] Primary manual aspiration thrombectomy (MAT) for acute ischemic stroke: safety, feasibility and outcomes in 112 consecutive patients
    Jankowitz, Brian
    Grandhi, Ramesh
    Horev, Anat
    Aghaebrahim, Amin
    Jadhav, Ashutosh
    Linares, Guillermo
    Jovin, Tudor
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (01) : 27 - 31