Comparison of treatment of oblique and spiral metacarpal and phalangeal fractures with mini plate plus screw or screw only

被引:47
作者
Basar, Hakan [1 ]
Basar, Betul [2 ]
Basci, Onur [3 ]
Topkar, Osman Mert [3 ]
Erol, Bulent [3 ]
Tetik, Cihangir [4 ]
机构
[1] Sakarya Training & Res Hosp, Dept Orthopaed & Traumatol, Serdivan, Sakarya, Turkey
[2] Akyazi State Hosp, Dept Phys Med & Rehabil, Sakarya, Turkey
[3] Marmara Univ, Dept Orthopaed & Traumatol, Sch Med, Istanbul, Turkey
[4] Acibadem Maslak Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
关键词
Mini plate plus screw; Metacarpal fracture; Phalangeal fracture; Spiral fracture; Oblique fracture; HAND FRACTURES; INTERNAL-FIXATION; COMPLICATIONS;
D O I
10.1007/s00402-015-2164-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We aimed to compare results of treatment of oblique-spiral metacarpal and phalangeal fractures with screw only or mini plate plus screw, respectively. A total of 43 patients who were operated with a diagnosis of displaced, irreducible, unstable, rotational oblique-spiral metacarpal and proximal phalangeal fracture between 2007 and 2010 were included in this study. The mean age of patients with a phalangeal fracture was 33.8 years (range 20-50 years; 4 females, 18 males), and the mean age of patients with a metacarpal fracture was 29.6 years (range 18-45 years; 3 females, 18 males). Mini plate plus screw or screw only was used for internal fixation of these fractures. The patients were followed up for 19.2 +/- A 5.4 months in the phalangeal fracture group and 20.9 +/- A 7.3 months in metacarpal fracture group. Of the metacarpal fractures, 14 were oblique and 10 spiral, whereas 14 of the phalangeal fractures were oblique and 8 spiral. The patients were evaluated according to total range of motion of the finger, grasping strength and Q-DASH score. For patients treated with mini plate plus screw after metacarpal and phalangeal fractures, the time to return to work was significantly shorter in comparison to patients treated with screws only. There was no significant difference between patients with metacarpal fractures treated with mini plate plus screw and patients treated with screw only in terms of total range of motion and Q-DASH results at last on control examination, while results of patients with phalangeal fractures treated with screw only were significantly better. There was no significant difference between these two treatments in phalangeal fractures in terms of grasping strength of the finger in early (1st month) and late (last control examination), whereas patients with metacarpal fractures treated with mini plate plus screw reached higher grasping strength earlier. Treatment with mini plate plus screw should be avoided in spiral and oblique phalangeal fractures, and fixation should be done with screw only with a short surgical incision and dissection. On the other hand, treatment with mini plate plus screw should be preferred in patients with spiral and oblique metacarpal fractures, especially in those who work in occupations requiring higher physical strength.
引用
收藏
页码:499 / 504
页数:6
相关论文
共 17 条
  • [1] The Biomechanics of Fixation Techniques for Hand Fractures
    Adams, Julie E.
    Miller, Thomas
    Rizzo, Marco
    [J]. HAND CLINICS, 2013, 29 (04) : 493 - +
  • [2] Experience with a new ultralow-profile osteosynthesis system for fractures of the metacarpals and phalanges
    Agarwal, Anil K.
    Pickford, Mark A.
    [J]. ANNALS OF PLASTIC SURGERY, 2006, 57 (02) : 206 - 212
  • [3] Ten Years Stable Internal Fixation of Metacarpal and Phalangeal Hand Fractures-Risk Factor and Outcome Analysis Show No Increase of Complications in the Treatment of Open Compared With Closed Fractures
    Bannasch, Holger
    Heermann, Anne K.
    Iblher, Niklas
    Momeni, Arash
    Schulte-Moenting, Juergen
    Stark, G. Bjoern
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (03): : 624 - 628
  • [4] THE STABILITY OF INTERNAL-FIXATION IN THE PROXIMAL PHALANX
    BLACK, DM
    MANN, RJ
    CONSTINE, RM
    DANIELS, AU
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1986, 11A (05): : 672 - 677
  • [5] Treatment of Phalangeal Fractures
    Carpenter, Shannon
    Rohde, Rachel S.
    [J]. HAND CLINICS, 2013, 29 (04) : 519 - +
  • [6] Use of eight-hole titanium miniplates for unstable phalangeal fractures
    Curtin, CM
    Chung, KC
    [J]. ANNALS OF PLASTIC SURGERY, 2002, 49 (06) : 580 - 586
  • [7] OPEN HAND FRACTURES - AN ANALYSIS OF THE RECOVERY OF ACTIVE MOTION AND OF COMPLICATIONS
    DUNCAN, RW
    FREELAND, AE
    JABALEY, ME
    MEYDRECH, EF
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (03): : 387 - 394
  • [8] Freeland AE, 2001, J BONE JOINT SURG AM, V83A, P928
  • [9] Gupta Rakesh, 2007, Indian J Orthop, V41, P224, DOI 10.4103/0019-5413.33687
  • [10] Henry MH, 2006, ROCKWOOD GREENS FRAC, V1, P772