Semi-analytical thermo-mechanical model for the shield tunnel segmental joint subjected to elevated temperatures

被引:17
作者
Shen, Yi [2 ,3 ]
Zhu, He-hua [1 ,2 ]
Yan, Zhi-guo [1 ,2 ]
Zhou, Long [2 ,3 ]
Lu, Yong [4 ]
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
[2] Tongji Univ, Dept Geotech Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
[3] Tongji Univ, Key Lab Geotech & Underground Engn, Minist Educ, 1239 Siping Rd, Shanghai 200092, Peoples R China
[4] Univ Edinburgh, Inst Infrastruct & Environm, Sch Engn, Edinburgh EH9 3JL, Midlothian, Scotland
基金
国家重点研发计划;
关键词
Shield tunnel; Segmental joint; Fire; Semi-analytical model; REINFORCED-CONCRETE; LININGS; BEHAVIOR;
D O I
10.1016/j.tust.2021.104170
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The segmental joint is the most critical component for determining the mechanical response of concrete segmental linings in a shield-tunnel structure. Existing segmental joint models have been developed mainly for the analysis of segmental lining design, but in the event of a fire, the conditions that a tunnel joint may experience could well exceed the normal design range. Consequently, the validity of the existing segmental joint models becomes questionable. In this paper, an improved semi-analytical thermo-mechanical model is derived based on the general plane joint model to consider the thermal effect induced by elevated temperatures. As a benchmark for the development of the model, a laboratory experiment was conducted on concrete lining segmental joints under elevated temperatures. The general heat transfer and special heat flow invading through the joint were deduced by theorical and numerical methods. A finite element (FE) model is developed and calibrated against experimental model tests, whilst the FE model is employed to generate the required parametric data, from which a fitting function is created. A temperature adjustment coefficient is introduced to improve the calculation of the joint section temperature field. The influence of elevated temperature and axial force on the bending moment of a segmental joint is also incorporated according to the stress state of the joint section. The validation of the proposed semi-analytical thermo-mechanical model is demonstrated through comparisons with the results of fire tests. Finally, the influences of the heating curves, bolt location, and axial load on the rotation stiffness of the joint are investigated using the proposed model.
引用
收藏
页数:14
相关论文
共 37 条
[11]   Deformational responses of operated shield tunnel to extreme surcharge: a case study [J].
Huang, Hongwei ;
Shao, Hua ;
Zhang, Dongming ;
Wang, Fei .
STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2017, 13 (03) :345-360
[12]   Load-carrying capability of shield tunnel damaged by shield shell squeezing action during construction [J].
Jin, Hao ;
Yu, Kaiwen ;
Gong, Quanmei ;
Zhou, Shunhua .
THIN-WALLED STRUCTURES, 2018, 132 :69-78
[13]   Fire resistant behavior of newly developed bottom-ash-based cementitious coating applied concrete tunnel lining under RABT fire loading [J].
Kim, Jang-Ho Jay ;
Lim, Yun Mook ;
Won, Jong Pil ;
Park, Hae Geun .
CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (10) :1984-1994
[14]   Present status and technology of shield tunneling method in Japan [J].
Koyama, Y .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2003, 18 (2-3) :145-159
[15]   The equivalence of a jointed shield-driven tunnel lining to a continuous ring structure [J].
Lee, KM ;
Ge, XW .
CANADIAN GEOTECHNICAL JOURNAL, 2001, 38 (03) :461-483
[16]   A progressive model to simulate the full mechanical behavior of concrete segmental lining longitudinal joints [J].
Li, Xiaojun ;
Yan, Zhiguo ;
Wang, Zhen ;
Zhu, Hehua .
ENGINEERING STRUCTURES, 2015, 93 :97-113
[17]   Experimental and analytical study on longitudinal joint opening of concrete segmental lining [J].
Li, Xiaojun ;
Yan, Zhiguo ;
Wang, Zhen ;
Zhu, Hehua .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2015, 46 :52-63
[18]  
Lie T.T., 1990, J FIRE PROT ENG, V2, P111, DOI [10.1177/104239159000200402, DOI 10.1177/104239159000200402]
[19]   Behaviours of concentrically and eccentrically loaded square steel tube confined reinforced concrete slender columns after fire exposure [J].
Liu, Faqi ;
Yang, Hua ;
Wang, Wei .
THIN-WALLED STRUCTURES, 2021, 158
[20]   A Heat-Transfer Rate Inducing System (H-TRIS) Test Method [J].
Maluk, Cristian ;
Bisby, Luke ;
Krajcovic, Michal ;
Torero, Jose Luis .
FIRE SAFETY JOURNAL, 2019, 105 :307-319