Optimization of orthodontic microimplant thread design

被引:4
|
作者
Kim, Kwang-Duk [1 ]
Yu, Won-Jae [1 ]
Park, Hyo-Sang [1 ]
Kyung, Hee-Moon [1 ]
Kwon, Oh-Won [1 ]
机构
[1] Kyungpook Natl Univ, Sch Dent, Dept Orthodont, Taegu 700412, South Korea
关键词
Orthodontic microimplant; Thread; Design optimization; Insertion strain; Finite element analysis; Torsional strength; FINITE-ELEMENT-ANALYSIS; CORTICAL BONE THICKNESS; IMPLANT STABILITY; MINI-IMPLANTS; SCREWS; PLACEMENT; ANCHORAGE; SUCCESS; STRAIN; PITCH;
D O I
10.4041/kjod.2011.41.1.25
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The purpose of this study was to optimize the thread pattern of orthodontic microimplants. Methods: In search of an optimal thread for orthodontic microimplants, an objective function stability quotient (SQ) was built and solved which will help increase the stability and torsional strength of microimplants while reducing the bone damage during insertion. Selecting the AbsoAnchor SH1312-7 microimplant (Dentos Inc., Daegu, Korea) as a control, and using the thread height (h) and pitch (p) as design parameters, new thread designs with optimal combination of h and p combination were developed. Design soundness of the new threads were examined through insertion strain analyses using 3D finite element simulation, torque test, and clinical test. Results: Solving the function SQ, four new models with optimized thread designs were developed (h200p6, h225p7, h250p8, and h275p8). Finite element analysis has shown that these new designs may cause less bone damage during insertion. The torsional strength of two models h200p6 and h225p7 were significantly higher than the control. On the other hand, clinical test of models h200p6 and h250p8 had similar success rates when compared to the control. Conclusion: Overall, the new thread designs exhibited better performance than the control which indicated that the optimization methodology may be a useful tool when designing orthodontic microimplant threads. (Korean J Orthod 2011;41(1):25-35)
引用
收藏
页码:25 / 35
页数:11
相关论文
共 50 条
  • [1] Effect of surface anodization on stability of orthodontic microimplant
    Karmarker, Sanket
    Yu, Wonjae
    Kyung, Hee-Moon
    KOREAN JOURNAL OF ORTHODONTICS, 2012, 42 (01) : 4 - 10
  • [2] FACTORS AFFECTING THE EFFECT OF MICROIMPLANT TREATMENT FOR ORTHODONTIC PATIENTS
    Chen, Liang
    Xi, Du
    ACTA MEDICA MEDITERRANEA, 2022, 38 (01): : 535 - 539
  • [3] Treatment of Class II Malocclusion With Orthodontic Microimplant Anchorage
    Zhao, Huanhuan
    Sun, Ru
    Cao, Sumin
    Han, Jingmei
    INTERNATIONAL DENTAL JOURNAL, 2024, 74 (03) : 536 - 542
  • [4] Clinical Applications of Orthodontic Microimplant Anchorage in Craniofacial Patients
    Vachiramon, Amornpong
    Urata, Mark
    Kyung, Hee Moon
    Yamashita, Dennis-Duke
    Yen, Stephen L. -K.
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 2009, 46 (02): : 136 - 146
  • [5] Bivariate optimization of orthodontic mini-implant thread height and pitch
    Shuning Shen
    Yingying Sun
    Chen Zhang
    Yongjin Yang
    Zhiren Li
    Xingwei Cai
    Yinzhong Duan
    Tao Li
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 109 - 116
  • [6] Bivariate optimization of orthodontic mini-implant thread height and pitch
    Shen, Shuning
    Sun, Yingying
    Zhang, Chen
    Yang, Yongjin
    Li, Zhiren
    Cai, Xingwei
    Duan, Yinzhong
    Li, Tao
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (01) : 109 - 116
  • [7] Optimization Analysis of Two-Factor Continuous Variable between Thread Depth and Pitch of Microimplant under Toque Force
    Ye, Yushan
    Jiao, Jiuyang
    Fan, Song
    He, Jieying
    Wang, Yamei
    Yao, Qinghe
    Wang, Wei
    Li, Jinsong
    Chang, Shaohai
    Computational and Mathematical Methods in Medicine, 2022, 2022
  • [8] Optimization Analysis of Two-Factor Continuous Variable between Thread Depth and Pitch of Microimplant under Toque Force
    Ye, Yushan
    Jiao, Jiuyang
    Fan, Song
    He, Jieying
    Wang, Yamei
    Yao, Qinghe
    Wang, Wei
    Li, Jinsong
    Chang, Shaohai
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2022, 2022
  • [9] Minimum required length of orthodontic microimplant: a numerical simulation and clinical validation
    Kum, Jaemin
    Park, Kyung-Ho
    Kim, Ho-Jin
    Hong, Mihee
    Yu, Wonjae
    Park, Hyo-Sang
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2023, 163 (06) : 858 - 866
  • [10] Analysis and optimization of tolerance design for an internal thread grinder
    Jiang, Qiao
    Ou, Yi
    Zou, Yun
    Zhou, Chang-Guang
    Huang, Sen
    Qian, Chao-Qun
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2023, 125 (11-12): : 5369 - 5383