Ancillary Service for Transmission Systems by Tap Stagger Operation in Distribution Networks

被引:23
作者
Chen, Linwei [1 ]
Li, Hai Yu [1 ]
Cox, Steve [2 ]
Bailey, Kieran [2 ]
机构
[1] Univ Manchester, Sch Elect & Elect Engn, Manchester M13 9PL, Lancs, England
[2] Elect North West, Salford M6 6AP, Lancs, England
关键词
Distribution network; parallel transformer; reactive power support; tap stagger and transmission system; VOLTAGE SUPPORT; POWER-SYSTEMS; SEARCH;
D O I
10.1109/TPWRD.2015.2504599
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the integration of intermittent renewable generation, transmission voltage problems have become more dynamic. The deployment and tuning of numbers of VAr compensators at various locations may not be cost-effective. This paper presents an alternative method, which utilizes existing parallel transformers in distribution networks, to provide reactive power absorption services for transmission systems with low demands. The operation of parallel transformers in small different tap positions, that is, with staggered taps, can provide a means of absorbing reactive power. The aggregated VAr absorption from many pairs of parallel transformers could be used to provide voltage support to the upstream transmission network. This paper focuses on the economic and technical analyses of using the tap staggering method. For the economic analysis, the associated costs of applying the tap staggering technique are investigated through static load-flow studies. The IEEE Reliability Test System is used to carry out the studies and the results are compared with the installation of shunt reactors. In the technical studies, the dynamic impacts of tap staggering or reactor switching on transmission voltages are analyzed. From the results, the tap staggering technique has more economic advantages than reactors and can reduce the voltage damping and overshoots during the transient states.
引用
收藏
页码:1701 / 1709
页数:9
相关论文
共 29 条
  • [1] A Multilevel Approach for Optimal Participating of Wind Farms at Reactive Power Balancing in Transmission Power System
    Ahmidi, Amir
    Guillaud, Xavier
    Besanger, Yvon
    Blanc, Regis
    [J]. IEEE SYSTEMS JOURNAL, 2012, 6 (02): : 260 - 269
  • [2] Techno-Economic Contribution of FACTS Devices to the Operation of Power Systems With High Level of Wind Power Integration
    Alhasawi, Faisal B.
    Milanovic, Jovica V.
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2012, 27 (03) : 1414 - 1421
  • [3] [Anonymous], 2015, ASS HLTH FIN REP CLA
  • [4] [Anonymous], 2014, DIgSILENT PowerFactory
  • [5] [Anonymous], 2015, C571532015 IEEE
  • [6] Chen L., 2014, IEEE POW EN SOC INN
  • [7] Comparative analysis between conventional voltage control using reactors and continuous voltage control using TCR in the Romanian Transmission Grid
    Constantin, Mirea
    Eremia, Mircea
    Toma, Lucian
    [J]. 2013 IEEE GRENOBLE POWERTECH (POWERTECH), 2013,
  • [8] Optimal reactive power dispatch using a gravitational search algorithm
    Duman, S.
    Sonmez, Y.
    Guvenc, U.
    Yorukeren, N.
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2012, 6 (06) : 563 - 576
  • [9] A secondary voltage control strategy for transmission level interconnection of wind generation
    El Moursi, Mohammed
    Joos, Geza
    Abbey, Chad
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (03) : 1178 - 1190
  • [10] The IEEE reliability test system - 1996
    Grigg, C
    Wong, P
    Albrecht, P
    Allan, R
    Bhavaraju, M
    Billinton, R
    Chen, Q
    Fong, C
    Haddad, S
    Kuruganty, S
    Li, W
    Mukerji, R
    Patton, D
    Rau, N
    Reppen, D
    Schneider, A
    Shahidehpour, M
    Singh, C
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 1999, 14 (03) : 1010 - 1018