Mapping Visual Field Defects With fMRI - Impact of Approach and Experimental Conditions

被引:8
|
作者
Prabhakaran, Gokulraj T. T. [1 ]
Al-Nosairy, Khaldoon O. O. [1 ]
Tempelmann, Claus [2 ]
Thieme, Hagen [1 ]
Hoffmann, Michael B. B. [1 ,3 ]
机构
[1] Otto Von Guericke Univ, Dept Ophthalmol, Magdeburg, Germany
[2] Otto Von Guericke Univ, Dept Neurol, Magdeburg, Germany
[3] Ctr Behav Brain Sci, Magdeburg, Germany
基金
欧盟地平线“2020”;
关键词
vision; human visual cortex; scotoma; perimetry; retinotopy; glaucoma; retinitis pigmentosa; atlas; MACULAR DEGENERATION; CORTEX; PERIMETRY; GLAUCOMA; MAPS; REORGANIZATION; MANAGEMENT; STABILITY; STIMULI; HUMANS;
D O I
10.3389/fnins.2021.745886
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Current initiatives to restore vision emphasize the need for objective assessments of visual field (VF) defects as pursued with functional magnetic resonance imaging (fMRI) approaches. Here, we compared population receptive field (pRF) mapping-based VF reconstructions to an fMRI method that uses more robust visual stimulation (on-off block design) in combination with individualized anatomy-driven retinotopic atlas-information (atlas-based VF). We investigated participants with sizable peripheral VF-deficits due to advanced glaucoma (n = 4) or retinitis pigmentosa (RP; n = 2) and controls (n = 6) with simulated scotoma. We obtained (1) standard automated perimetry (SAP) data as reference VFs and 3T fMRI data for (2) pRF-mapping [8-direction bar stimulus, fixation color change task] and (3) block-design full-field stimulation [8-direction drifting contrast patterns during (a) passive viewing (PV) and (b) one-back-task (OBT; reporting successions of identical motion directions) to probe the impact of previously reported task-related unspecific visual cortex activations]. Correspondence measures between the SAP and fMRI-based VFs were accuracy, assisted by sensitivity and specificity. We found an accuracy of pRF-based VF from V1 in patients [median: 0.62] that was similar to previous reports and increased by adding V2 and V3 to the analysis [0.74]. In comparison to the pRF-based VF, equivalent accuracies were obtained for the atlas-based VF for both PV [0.67] and, unexpectedly, the OBT [0.59], where, however, unspecific cortical activations were reflected by a reduction in sensitivity [0.71 (PV) and 0.35 (OBT)]. In conclusion, in patients with peripheral VF-defects, we demonstrate that previous fMRI procedures to obtain VF-estimates might be enhanced by: (1) pooling V1-V3 to enhance accuracy; (2) reporting sensitivity and specificity measures to increase transparency of the VF-reconstruction metric; (3) applying atlas-based procedures, if pRF-based VFs are not available or difficult to obtain; and (4) giving, counter-intuitively, preference to PV. These findings are expected to provide guidance to overcome current limitations of translating fMRI-based methods to a clinical work-up.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Visual Field Reconstruction in Hemianopia Using fMRI Based Mapping Techniques
    Halbertsma, Hinke N.
    Bridge, Holly
    Carvalho, Joana
    Cornelissen, Frans W.
    Ajina, Sara
    FRONTIERS IN HUMAN NEUROSCIENCE, 2021, 15
  • [2] Visual Field Reconstruction Using fMRI-Based Techniques
    Carvalho, Joana
    Invernizzi, Azzurra
    Martins, Joana
    Jansonius, Nomdo M.
    Renken, Remco J.
    Cornelissen, Frans W.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (01): : 1 - 18
  • [3] Evaluating the Performance of qVFM in Mapping the Visual Field of Simulated Observers With Eye Diseases
    Xu, Pengjing
    Lesmes, Luis Andres
    Yu, Deyue
    Lu, Zhong-Lin
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [4] Changes in cortical grey matter density associated with long-standing retinal visual field defects
    Boucard, Christine C.
    Hernowo, Aditya T.
    Maguire, R. Paul
    Jansonius, Nomdo M.
    Roerdink, Jos B. T. M.
    Hooymans, Johanna M. M.
    Cornelissen, Frans W.
    BRAIN, 2009, 132 : 1898 - 1906
  • [5] Evaluation of advanced visual field defects by computer assisted kinetic perimetry
    Schiefer, U
    Schiller, J
    Paetzold, J
    Dietrich, TJ
    Vonthein, R
    Besch, D
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (01) : 13 - 20
  • [6] Objective detection of visual field defects with multifrequency VEPs
    Crux, Katja
    Huchzermeyer, Cord
    Kremers, Jan
    Horn, Folkert K.
    DOCUMENTA OPHTHALMOLOGICA, 2024, 148 (01) : 15 - 24
  • [7] Suprathreshold Approaches to Mapping the Visual Field in Advanced Glaucoma
    Denniss, Jonathan
    Mckendrick, Allison M.
    Turpin, Andrew
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2023, 12 (06):
  • [8] Are Visual Field Defects Reversible? - Visual Rehabilitation with Brains
    Sabel, B. A.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2017, 234 (02) : 194 - 204
  • [9] Glaucomatous visual field defects: Their characteristics and how to detect them
    Kitazawa, Y
    Yamamoto, T
    CLINICAL NEUROSCIENCE, 1997, 4 (05) : 279 - 283
  • [10] Comparison Between MP-1 and Humphrey Visual Field Defects in Glaucoma and Retinitis Pigmentosa
    Acton, Jennifer H.
    Smith, R. Theodore
    Greenberg, Jonathan P.
    Greenstein, Vivienne C.
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (07) : 1050 - 1058