Objective: This study aimed to compare gas exchange with heliox and oxygen-enriched air during piston-type high-frequency oscillatory ventilation (HFOV). We hypothesized that helium gas would improve both carbon dioxide elimination and arterial oxygenation during piston-type HFOV. Method: Five rabbits were prepared and ventilated by piston-type HFOV with carrier 50% helium/oxygen (heliox50) or 50% oxygen/nitrogen (nitrogen50) gas mixture in a crossover study. Changing the gas mixture from nitrogen50 to heliox50 and back was performed five times per animal with constant ventilation parameters. Arterial blood gas, vital function and respiratory test indices were recorded. Results: Compared with nitrogen50, heliox50 did not change PaCO2 when stroke volume remained constant, but significantly reduced PaCO2 after alignment of amplitude pressure. No significant changes in PaO2 were seen despite significant decreases in mean airway pressure with heliox50 compared with nitrogen50. Conclusion: This study demonstrated that heliox enhances CO2 elimination and maintains oxygenation at the same amplitude but with lower airway pressure compared to air/O-2 mix gas during piston-type HFOV.
引用
收藏
页数:5
相关论文
共 15 条
  • [1] Clinical review: Use of helium-oxygen in critically ill patients
    Gainnier, Marc
    Forel, Jean-Marie
    [J]. CRITICAL CARE, 2006, 10 (06):
  • [2] Gupta Vineet K, 2004, Respir Care, V49, P1038
  • [3] Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators
    Hatcher, D
    Watanabe, H
    Ashbury, T
    Vincent, S
    Fisher, J
    Froese, A
    [J]. CRITICAL CARE MEDICINE, 1998, 26 (06) : 1081 - 1088
  • [4] Hurford WE, 2007, RESP CARE, V52, P582
  • [5] HIGH-FREQUENCY VENTILATION IN DOGS WITH 3 GASES OF DIFFERENT DENSITIES
    JAEGER, MJ
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (05) : 2188 - 2192
  • [6] Assessment of high-frequency neonatal ventilator performances
    Jouvet, P
    Hubert, P
    Isabey, D
    Pinquier, D
    Dahan, E
    Cloup, M
    Harf, A
    [J]. INTENSIVE CARE MEDICINE, 1997, 23 (02) : 208 - 213
  • [7] Heliox improves gas exchange during high-frequency ventilation in a pediatric model of acute lung injury
    Katz, A
    Gentile, MA
    Craig, DM
    Quick, G
    Meliones, JN
    Cheifetz, IM
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (02) : 260 - 264
  • [8] Heliox does not affect gas exchange during high-frequency oscillatory ventilation if tidal volume is held constant
    Katz, AL
    Gentile, MA
    Craig, DM
    Quick, G
    Cheifetz, IM
    [J]. CRITICAL CARE MEDICINE, 2003, 31 (07) : 2006 - 2009
  • [9] High-frequency ventilation for acute lung injury and ARDS
    Krishnan, JA
    Brower, RG
    [J]. CHEST, 2000, 118 (03) : 795 - 807
  • [10] Effect of air and heliox as carrier gas on CO2 transport in a model of high-frequency oscillation comparing two oscillators
    Mildner, RJ
    Frndova, H
    Cox, PN
    [J]. CRITICAL CARE MEDICINE, 2003, 31 (06) : 1759 - 1763