Audiological outcome measures with the BONEBRIDGE transcutaneous bone conduction hearing implant: impact of noise, reverberation and signal processing features

被引:10
作者
Curca, Ioan A. [1 ,2 ]
Parsa, Vijay [1 ,2 ]
Macpherson, Ewan A. [1 ,2 ]
Scollie, Susan [1 ,2 ]
Vansevenant, Katherine [3 ]
Zimmerman, Kim [3 ]
Lewis-Teeter, Jamie [3 ]
Allen, Prudence [1 ,2 ]
Parnes, Lorne [3 ,4 ]
Agrawal, Sumit [3 ,4 ]
机构
[1] Western Univ, Sch Commun Sci & Disorders, London, ON, Canada
[2] Univ Western Ontario, Fac Hlth Sci, Natl Ctr Audiol, 1201 Western Rd,Elborn Coll Room 2593, London, ON N6G 1H1, Canada
[3] London Hlth Sci Ctr, Cochlear Implant Program, London, ON, Canada
[4] Univ Western Ontario, Schulich Sch Med, Dept Otolaryngol Head & Neck Surg, London, ON, Canada
关键词
Bone-anchored hearing aid; BONEBRIDGE; directional microphone; noise reduction; reverberation; APHAB; speech intelligibility; sound quality; DIRECTIONAL MICROPHONE; REDUCTION; SURGERY; SYSTEM; QUIET;
D O I
10.1080/14992027.2020.1728400
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: To assess the performance of an active transcutaneous implantable-bone conduction device (TI-BCD), and to evaluate the benefit of device digital signal processing (DSP) features in challenging listening environments. Design: Participants were tested at 1- and 3-month post-activation of the TI-BCD. At each session, aided and unaided phoneme perception was assessed using the Ling-6 test. Speech reception thresholds (SRTs) and quality ratings of speech and music samples were collected in noisy and reverberant environments, with and without the DSP features. Self-assessment of the device performance was obtained using the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire. Study sample: Six adults with conductive or mixed hearing loss. Results: Average SRTs were 2.9 and 12.3 dB in low and high reverberation environments, respectively, which improved to -1.7 and 8.7 dB, respectively with the DSP features. In addition, speech quality ratings improved by 23 points with the DSP features when averaged across all environmental conditions. Improvement scores on APHAB scales revealed a statistically significant aided benefit. Conclusions: Noise and reverberation significantly impacted speech recognition performance and perceived sound quality. DSP features (directional microphone processing and adaptive noise reduction) significantly enhanced subjects' performance in these challenging listening environments.
引用
收藏
页码:556 / 565
页数:10
相关论文
共 38 条
  • [31] Fitting Noise Management Signal Processing Applying the American Academy of Audiology Pediatric Amplification Guideline: Verification Protocols
    Scollie, Susan
    Levy, Charla
    Pourmand, Nazanin
    Abbasalipour, Parvaneh
    Bagatto, Marlene
    Richert, Frances
    Moodie, Shane
    Crukley, Jeff
    Parsa, Vijay
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2016, 27 (03) : 237 - 251
  • [32] Stimuli and Normative Data for Detection of Ling-6 Sounds in Hearing Level
    Scollie, Susan
    Glista, Danielle
    Tenhaaf, Julianne
    Dunn, Andrea
    Malandrino, April
    Keene, Kelley
    Folkeard, Paula
    [J]. AMERICAN JOURNAL OF AUDIOLOGY, 2012, 21 (02) : 232 - 241
  • [33] Development and Validation of the AzBio Sentence Lists
    Spahr, Anthony J.
    Dorman, Michael F.
    Litvak, Leonid M.
    Van Wie, Susan
    Gifford, Rene H.
    Loizou, Philipos C.
    Loiselle, Louise M.
    Oakes, Tyler
    Cook, Sarah
    [J]. EAR AND HEARING, 2012, 33 (01) : 112 - 117
  • [34] The Bonebridge Bone Conduction Hearing Implant: indication criteria, surgery and a systematic review of the literature
    Sprinzl, G. M.
    Wolf-Magele, A.
    [J]. CLINICAL OTOLARYNGOLOGY, 2016, 41 (02) : 131 - 143
  • [35] Sprinzl G, 2013, OTOL NEUROTOL, V34, P1076, DOI 10.1097/MAO.0b013e31828bb541
  • [36] Feedback Analysis in Percutaneous Bone-Conduction Device and Bone-Conduction Implant on a Dry Cranium
    Taghavi, Hamidreza
    Hakansson, Bo
    Reinfeldt, Sabine
    Eeg-Olofsson, Mans
    Akhshijan, Shirin
    [J]. OTOLOGY & NEUROTOLOGY, 2012, 33 (03) : 413 - 420
  • [37] Comparison of the Audiologic Results Obtained With the Bone-Anchored Hearing Aid Attached to the Headband, the Testband, and to the "Snap" Abutment
    Verstraeten, Nadia
    Zarowski, Andrzej J.
    Somers, Thomas
    Riff, Daphna
    Offeciers, Erwin F.
    [J]. OTOLOGY & NEUROTOLOGY, 2009, 30 (01) : 70 - 75
  • [38] Zernotti ME, 2015, INT ARCH OTORHINOLAR, V19, P343