The posterior superior iliac spine and sacral laminar slope: key anatomical landmarks for freehand S2-alar-iliac screw placement

被引:16
作者
Lin, James D. [1 ]
Tan, Lee A. [2 ]
Wei, Chao [3 ]
Shillingford, Jamal N. [1 ]
Laratta, Joseph L. [1 ]
Lombardi, Joseph M. [1 ]
Kim, Yongjung J. [1 ]
Lehman, Ronald A., Jr. [1 ]
Lenke, Lawrence G. [1 ]
机构
[1] Columbia Univ, Med Ctr, Spine Hosp NewYork Presbyterian Allen, Dept Orthoped Surg, New York, NY USA
[2] Univ Calif San Francisco, Dept Neurol Surg, Med Ctr, San Francisco, CA USA
[3] Fujian Med Univ, Dept Spine Surg, Affiliated Hosp 1, Fuzhou, Fujian, Peoples R China
关键词
S2AI; freehand; S2-alar-iliac; pelvis; sacropelvic fixation; sacral; SACROPELVIC FIXATION; PELVIC FIXATION;
D O I
10.3171/2018.3.SPINE171374
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE The S2-alar-iliac (S2AI) screw is an increasingly popular method for spinopelvic fixation. The technique of freehand S2AI screw placement has been recently described. The purpose of this study was to demonstrate, through a CT imaging study of patients with spinal deformity, that screw trajectories based on the posterior superior iliac spine (PSIS) and sacral laminar slope result in reliable freehand S2AI trajectories that traverse safely above the sciatic notch. METHODS Fifty consecutive patients (age >= 18 years) who underwent primary spinal deformity surgery were included in the study. Simulated S2AI screw trajectories were analyzed with 3D visualization software. The cephalocaudal coordinate for the starting point was 15 mm cephalad to the PSIS. The mediolateral coordinate for the starting point was in line with the lateral border of the dorsal foramina. The cephalocaudal screw trajectory was perpendicular to the sacral laminar slope. Screw trajectories, lengths, and distance above the sciatic notch were measured. RESULTS The mean sagittal screw angle (cephalocaudal angulation) was 44.0 degrees +/- 8.4 degrees and the mean transverse angle (mediolateral angulation) was 37.3 degrees +/- 4.3 degrees. The mean starting point was 5.9 +/- 5.8 mm distal to the caudal border of the S1 foramen. The mean screw length was 99.9 +/- 18.6 mm. Screw trajectories were on average 8.5 +/- 4.3 mm above the sciatic notch. A total of 97 of 100 screws were placed above the sciatic notch. In patients with transitional lumbosacral anatomy, the starting point on the lumbarized/sacralized side was 3.4 mm higher than on the contralateral unaffected side. CONCLUSIONS The PSIS and sacral laminar slope are two important anatomical landmarks for freehand S2AI screw placement.
引用
收藏
页码:429 / 434
页数:6
相关论文
共 48 条
  • [31] Is the Greater Trochanter the Ideal Freehand Landmark for the S2AI Screw Angle in the Caudal Direction? Commentary on "Extra-articular Portion of the Sacroiliac Joint-Between the Sacral and Pelvic Tuberosities: An Anatomical Guide for the S2-Alar-Iliac Screw Trajectory" by Tatara et al
    Yang, Panyi
    Tang, Xueyang
    GLOBAL SPINE JOURNAL, 2021, 11 (06) : 1008 - 1009
  • [32] In-Human Report of S2 Alar-Iliac Screw Placement Using Augmented Reality Assistance
    Judy, Brendan F.
    Liu, Ann
    Jin, Yike
    Ronkon, Charles
    Khan, Majid
    Cottrill, Ethan
    Ehresman, Jeff
    Pennington, Zach
    Bydon, Ali
    Lo, Sheng-Fu L.
    Sciubba, Daniel M.
    Molina, Camilo A.
    Witham, Timothy F.
    OPERATIVE NEUROSURGERY, 2023, 24 (01) : 68 - 73
  • [33] The Accurate Free-hand Placement of S2 Alar Iliac (S2AI) Screw
    Fang, Taolin
    Russo, Glenn S.
    Schroeder, Gregory D.
    Kepler, Christopher K.
    CLINICAL SPINE SURGERY, 2020, 33 (03): : 102 - 103
  • [34] Evaluation of iliac screw, S2 alar-iliac screw and laterally placed triangular titanium implants for sacropelvic fixation in combination with posterior lumbar instrumentation: a finite element study
    Gloria Casaroli
    Fabio Galbusera
    Ruchi Chande
    Derek Lindsey
    Ali Mesiwala
    Scott Yerby
    Marco Brayda-Bruno
    European Spine Journal, 2019, 28 : 1724 - 1732
  • [35] Quad S2-Alar-Iliac Screw Fixation via Navigated Spinal Robotics With Software Planning: 2-Dimensional Operative Video
    Pham, Martin H.
    Diaz-Aguilar, Luis Daniel
    King, Bradley H.
    Osorio, Joseph A.
    Lehman, Ronald A.
    OPERATIVE NEUROSURGERY, 2020, 19 (05) : E523 - E523
  • [36] Evaluation of iliac screw, S2 alar-iliac screw and laterally placed triangular titanium implants for sacropelvic fixation in combination with posterior lumbar instrumentation: a finite element study
    Casaroli, Gloria
    Galbusera, Fabio
    Chande, Ruchi
    Lindsey, Derek
    Mesiwala, Ali
    Yerby, Scott
    Brayda-Bruno, Marco
    EUROPEAN SPINE JOURNAL, 2019, 28 (07) : 1724 - 1732
  • [37] Letter to the editor. Both the starting point and referred landmark of S2-Alar-Iliac screw direction have not been unified
    Yang, Panyi
    Wang, Daoxi
    Tang, Xueyang
    JOURNAL OF CLINICAL NEUROSCIENCE, 2021, 89 : 448 - 450
  • [38] Accuracy of S2 Alar-Iliac Screw Placement Under the Guidance of a 3D-Printed Surgical Guide Template
    Zhao, Yonghui
    Luo, Haotian
    Ma, Yulong
    Liang, Jinlong
    Han, Gonghai
    Xu, Yongqing
    Lu, Sheng
    WORLD NEUROSURGERY, 2021, 146 : E161 - E167
  • [39] Biomechanical investigation of S2 alar-iliac screw and S1 pedicle screw fixation in the treatment of Denis type II sacral fractures
    Zheng, Jianxiong
    Liu, Fei
    Xiang, Jie
    Leung, Frankie K. L.
    Feng, Xiaoreng
    Chen, Bin
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (01) : 215 - 224
  • [40] Acute failure of S2-alar-iliac screw pelvic fixation in adult spinal deformity: novel failure mechanism, case series, and review of the literature
    Martin, Christopher T.
    Polly Jr, David W.
    Holton, Kenneth J.
    Miguel-Ruiz, Jose E. San
    Albersheim, Melissa
    Lender, Paul
    Sembrano, Jonathan N.
    Hunt, Matthew A.
    Jones, Kristen E.
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 36 (01) : 53 - 61